  "name": "Neuro-Oncology Response Assessment Criteria Evolution and Metric Thresholds",
  "description": "Comparative specifications of clinical response assessment frameworks in neuro-oncology, contrasting the 1990 Macdonald criteria, 2010 RANO high-grade glioma guidelines, and 2023 RANO 2.0 criteria across imaging modalities, measurement dimensions, progressive disease thresholds, pseudoprogression windows, and clinical integration rules.",
  "page": "https://casrai.org/guides/rano-criteria",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-22T10:50:00Z",
  "temporalCoverage": "1990/2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Framework",
      "unit": "",
      "description": "Framework Name and Clinical Lineage"
    },
    {
      "name": "Publication Year",
      "unit": "",
      "description": "Year of Primary Consensus Publication"
    },
    {
      "name": "Imaging Modality",
      "unit": "",
      "description": "Required MRI and CT Sequences"
    },
    {
      "name": "Measurement Dimension",
      "unit": "",
      "description": "Dimensional Measurement Methodology"
    },
    {
      "name": "Progressive Disease Threshold",
      "unit": "",
      "description": "Minimum Threshold for Progressive Disease"
    },
    {
      "name": "Partial Response Threshold",
      "unit": "",
      "description": "Minimum Threshold for Partial Response"
    },
    {
      "name": "Pseudoprogression Protocol",
      "unit": "",
      "description": "Post-Radiotherapy Pseudoprogression Rule"
    },
    {
      "name": "Clinical Integration",
      "unit": "",
      "description": "Neurological Assessment and Corticosteroid Standard"
    }
  ],
  "rows": [
    {
      "Framework": "Macdonald Criteria",
      "Publication Year": 1990,
      "Imaging Modality": "Contrast-enhanced CT or T1-MRI",
      "Measurement Dimension": "2D cross-sectional area (SPD)",
      "Progressive Disease Threshold": ">= 25% increase in SPD or any new tumor",
      "Partial Response Threshold": ">= 50% decrease in SPD",
      "Pseudoprogression Protocol": "None defined (predated concurrent chemoradiotherapy)",
      "Clinical Integration": "Qualitative neurological exam and steroid tracking"
    },
    {
      "Framework": "RANO 2010 (HGG)",
      "Publication Year": 2010,
      "Imaging Modality": "T1 contrast MRI and T2/FLAIR",
      "Measurement Dimension": "2D cross-sectional area (SPD)",
      "Progressive Disease Threshold": ">= 25% increase in SPD, substantial T2/FLAIR growth, or new tumor",
      "Partial Response Threshold": ">= 50% decrease in SPD with stable or improved T2/FLAIR",
      "Pseudoprogression Protocol": "Progression",
      "Clinical Integration": "Qualitative neurological assessment and steroid tracking"
    },
    {
      "Framework": "mRANO (Modified RANO)",
      "Publication Year": 2017,
      "Imaging Modality": "T1 contrast MRI and T2/FLAIR",
      "Measurement Dimension": "2D SPD or 3D volume",
      "Progressive Disease Threshold": ">= 25% increase in SPD or >= 40% increase in volume, confirmed on repeat scan",
      "Partial Response Threshold": ">= 50% decrease in SPD or >= 65% decrease in volume",
      "Pseudoprogression Protocol": "Mandatory confirmation MRI >= 4 weeks later for all suspected progression events",
      "Clinical Integration": "Neurological evaluation and steroid tracking"
    },
    {
      "Framework": "iRANO (Immunotherapy)",
      "Publication Year": 2015,
      "Imaging Modality": "T1 contrast MRI and T2/FLAIR",
      "Measurement Dimension": "2D cross-sectional area (SPD)",
      "Progressive Disease Threshold": ">= 25% increase in SPD confirmed on repeat scan if within 6 months of immunotherapy",
      "Partial Response Threshold": ">= 50% decrease in SPD",
      "Pseudoprogression Protocol": "Pseudoprogression window extends to 6 months post-immunotherapy with 3-month repeat scan",
      "Clinical Integration": "NANO scale or Karnofsky Performance Status (KPS)"
    },
    {
      "Framework": "RANO 2.0 (Adult Gliomas)",
      "Publication Year": 2023,
      "Imaging Modality": "Multiparametric MRI (T1+C, T2, FLAIR)",
      "Measurement Dimension": "2D SPD or 3D volume",
      "Progressive Disease Threshold": ">= 25% increase in 2D SPD or >= 40% increase in 3D volume from nadir, or new lesion",
      "Partial Response Threshold": ">= 50% decrease in 2D SPD or >= 65% decrease in 3D volume from baseline",
      "Pseudoprogression Protocol": "Post-RT baseline mandated; progression = 4 weeks later",
      "Clinical Integration": "NANO scale, KPS/ECOG, and mandatory steroid taper adjudication"
    }
  ],
  "sources": [
    {
      "title": "RANO 2.0: Update to the Response Assessment in Neuro-Oncology Criteria for High- and Low-Grade Gliomas in Adults",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10860967/",
      "accessed": "2026-11-20"
    },
    {
      "title": "RANO 2.0 criteria: concepts applicable to the neuroradiologist’s clinical practice",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11493521/",
      "accessed": "2026-11-20"
    },
    {
      "title": "The Neurologic Assessment in Neuro-Oncology (NANO) scale: a tool to assess neurologic function for integration into the Response Assessment in Neuro-Oncology (RANO) criteria",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5464449/",
      "accessed": "2026-11-20"
    },
    {
      "title": "First Site Activated And First Patient Randomised In New Brain Cancer Study VIGOR - EORTC-2427-BTG",
      "url": "https://www.eortc.org/blog/2026/01/26/first-site-activated-and-first-patient-randomised-in-new-brain-cancer-study-vigor-eortc-2427-btg/",
      "accessed": "2026-11-20"
    }
  ]
}