  "name": "Surgical Hemostatic Forceps Dimensional and Regulatory Specifications Matrix",
  "description": "Comparative technical specifications, regulatory classifications, serration profiles, and dimension ranges for major hemostatic forceps compiled from FDA 21 CFR regulations, AccessGUDID records, and ASTM F899 standards.",
  "page": "https://casrai.org/guides/rochester-pean",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T01:45:29Z",
  "temporalCoverage": "2024/2026",
  "spatialCoverage": "United States",
  "columns": [
    {
      "name": "Instrument Pattern",
      "unit": "",
      "description": "Standard surgical hemostat pattern name"
    },
    {
      "name": "FDA Regulation",
      "unit": "",
      "description": "21 CFR classification regulation"
    },
    {
      "name": "FDA Product Code",
      "unit": "",
      "description": "Three-letter FDA classification product code"
    },
    {
      "name": "FDA Device Class",
      "unit": "",
      "description": "Premarket device risk classification"
    },
    {
      "name": "GMDN Preferred Term Code",
      "unit": "",
      "description": "Global Medical Device Nomenclature category code"
    },
    {
      "name": "Serration Pattern",
      "unit": "",
      "description": "Orientation and coverage of jaw serrations"
    },
    {
      "name": "Minimum Overall Length",
      "unit": "mm",
      "description": "Standard minimum manufactured length in millimeters"
    },
    {
      "name": "Maximum Overall Length",
      "unit": "mm",
      "description": "Standard maximum manufactured length in millimeters"
    },
    {
      "name": "Primary Tissue Target",
      "unit": "",
      "description": "Anatomical application and tissue type"
    }
  ],
  "rows": [
    {
      "Instrument Pattern": "Rochester-Pean Forceps",
      "FDA Regulation": "21 CFR 878.4800",
      "FDA Product Code": "GDJ",
      "FDA Device Class": "Class I",
      "GMDN Preferred Term Code": "62468",
      "Serration Pattern": "Full transverse crosswise",
      "Minimum Overall Length": 140,
      "Maximum Overall Length": 305,
      "Primary Tissue Target": "Large blood vessels and heavy tissue pedicles"
    },
    {
      "Instrument Pattern": "Rochester-Carmalt Forceps",
      "FDA Regulation": "21 CFR 878.4800",
      "FDA Product Code": "GDJ",
      "FDA Device Class": "Class I",
      "GMDN Preferred Term Code": "62468",
      "Serration Pattern": "Longitudinal striations with cross-hatched tip",
      "Minimum Overall Length": 160,
      "Maximum Overall Length": 203,
      "Primary Tissue Target": "Thick vascular bundles and uterine/ovarian pedicles"
    },
    {
      "Instrument Pattern": "Rochester-Ochsner Forceps",
      "FDA Regulation": "21 CFR 878.4800",
      "FDA Product Code": "GEN",
      "FDA Device Class": "Class I",
      "GMDN Preferred Term Code": "62468",
      "Serration Pattern": "Full transverse with 1x2 interlocking teeth",
      "Minimum Overall Length": 140,
      "Maximum Overall Length": 254,
      "Primary Tissue Target": "Dense fibrous tissue and muscular fascia traction"
    },
    {
      "Instrument Pattern": "Crile Forceps",
      "FDA Regulation": "21 CFR 878.4800",
      "FDA Product Code": "GDJ",
      "FDA Device Class": "Class I",
      "GMDN Preferred Term Code": "62468",
      "Serration Pattern": "Full transverse serrations",
      "Minimum Overall Length": 140,
      "Maximum Overall Length": 160,
      "Primary Tissue Target": "Intermediate subcutaneous blood vessels"
    },
    {
      "Instrument Pattern": "Kelly Forceps",
      "FDA Regulation": "21 CFR 878.4800",
      "FDA Product Code": "GDJ",
      "FDA Device Class": "Class I",
      "GMDN Preferred Term Code": "62468",
      "Serration Pattern": "Partial transverse serrations (distal half)",
      "Minimum Overall Length": 140,
      "Maximum Overall Length": 160,
      "Primary Tissue Target": "Medium-sized vessels and soft tissue dissection"
    },
    {
      "Instrument Pattern": "Halsted-Mosquito Forceps",
      "FDA Regulation": "21 CFR 878.4800",
      "FDA Product Code": "GDJ",
      "FDA Device Class": "Class I",
      "GMDN Preferred Term Code": "62468",
      "Serration Pattern": "Fine full transverse serrations",
      "Minimum Overall Length": 90,
      "Maximum Overall Length": 125,
      "Primary Tissue Target": "Delicate micro-vessels and fine localized bleeding"
    }
  ],
  "sources": [
    {
      "title": "FDA 21 CFR § 878.4800: Manual surgical instrument for general use",
      "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/cfrsearch.cfm?fr=878.4800",
      "accessed": "2026-11-13"
    },
    {
      "title": "FDA AccessGUDID Database for Hemostatic Forceps",
      "url": "https://accessgudid.nlm.nih.gov/",
      "accessed": "2026-11-13"
    },
    {
      "title": "ASTM F899-23: Standard Specification for Wrought Stainless Steels for Surgical Instruments",
      "url": "https://www.astm.org/f0899-23.html",
      "accessed": "2026-11-13"
    }
  ]
}