  "name": "Salt fog corrosion test types: solution, pH, temperature and cycle (ASTM B117, ASTM G85, ISO 9227)",
  "description": "Compares the neutral, acidified, copper-accelerated and cyclic salt fog test types by solution, pH, chamber temperature and cycle, as tabulated by a corrosion testing laboratory and cross-checked against Q-Lab for B117.",
  "page": "https://casrai.org/guides/salt-spray-test",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-13T06:35:55Z",
  "temporalCoverage": "2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Test type",
      "unit": "",
      "description": ""
    },
    {
      "name": "Solution",
      "unit": "",
      "description": ""
    },
    {
      "name": "pH",
      "unit": "",
      "description": ""
    },
    {
      "name": "Chamber temperature",
      "unit": "°C",
      "description": ""
    },
    {
      "name": "Cycle",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Test type": "ASTM B117 (neutral salt spray)",
      "Solution": "5% NaCl (±1%)",
      "pH": "6.5-7.2",
      "Chamber temperature": "35 ±2",
      "Cycle": "Continuous fog"
    },
    {
      "Test type": "ISO 9227 NSS",
      "Solution": "Sodium chloride",
      "pH": "6.5-7.2",
      "Chamber temperature": "35 ±2",
      "Cycle": "Continuous fog"
    },
    {
      "Test type": "ISO 9227 AASS",
      "Solution": "Sodium chloride with acetic acid",
      "pH": "3.1-3.3",
      "Chamber temperature": "35 ±2",
      "Cycle": "Continuous fog"
    },
    {
      "Test type": "ISO 9227 CASS",
      "Solution": "Sodium chloride with 0.26 g/L CuCl2·2H2O",
      "pH": "3.1-3.3",
      "Chamber temperature": "50 ±2",
      "Cycle": "Continuous fog"
    },
    {
      "Test type": "ASTM G85 A1",
      "Solution": "NaCl with acetic acid",
      "pH": "3.1-3.3",
      "Chamber temperature": "35 ±2",
      "Cycle": "Continuous fog"
    },
    {
      "Test type": "ASTM G85 A2",
      "Solution": "5 ± 1% NaCl",
      "pH": "2.8-3.0",
      "Chamber temperature": "49 ±2 (fog phase)",
      "Cycle": "0.75 h fog, 2 h dry air purge, 3.25 h humidity"
    },
    {
      "Test type": "ASTM G85 A3",
      "Solution": "Synthetic sea salt",
      "pH": "2.8-3.0",
      "Chamber temperature": "24 to 35 or 49 ±2 (fog phase)",
      "Cycle": "0.5 h fog, 1.5 h humidity"
    },
    {
      "Test type": "ASTM G85 A5",
      "Solution": "0.35% (NH4)2SO4 + 0.05% NaCl",
      "pH": "5.0-5.4",
      "Chamber temperature": "35 ±1.5",
      "Cycle": "1 h fog, 1 h dry"
    }
  ],
  "sources": [
    {
      "title": "Micomlab corrosion testing guide: table of standards",
      "url": "https://www.micomlab.com/resources/corrosion-testing-guide/table-of-standards/",
      "accessed": "2026-11-13"
    },
    {
      "title": "Q-Lab ASTM B117",
      "url": "https://www.q-lab.com/corrosion/corrosion-test-standards/astm-b117",
      "accessed": "2026-11-13"
    }
  ]
}