  "name": "Idealized force-deflection behaviour of seismic isolation systems",
  "description": "Four categories of isolation-system behaviour as classified in the commentary to Chapter 17 of the NEHRP Recommended Seismic Provisions (2015), each drawn with the same design displacement. Compiled by CASRAI from the commentary text on effective period, force on the superstructure and displacement demand beyond the design level, and whether the standard's procedures apply.",
  "page": "https://casrai.org/guides/seismic-isolation",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-25T11:30:00Z",
  "temporalCoverage": "2015 NEHRP Provisions",
  "spatialCoverage": "United States",
  "columns": [
    {
      "name": "Behaviour category",
      "unit": "",
      "description": ""
    },
    {
      "name": "Effective period as displacement grows",
      "unit": "",
      "description": ""
    },
    {
      "name": "Effect beyond the design displacement",
      "unit": "",
      "description": ""
    },
    {
      "name": "Treatment in the standard",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Behaviour category": "Linear (curve A)",
      "Effective period as displacement grows": "Constant, independent of displacement demand",
      "Effect beyond the design displacement": "Force in the superstructure is directly proportional to isolation-system displacement",
      "Treatment in the standard": "Not excluded by the commentary"
    },
    {
      "Behaviour category": "Hardening (curve B)",
      "Effective period as displacement grows": "Long at first (low initial stiffness), then shorter at higher displacement",
      "Effect beyond the design displacement": "Superstructure force demand increases while isolation-system displacement is reduced, compared with an equivalent linear system",
      "Treatment in the standard": "Not excluded by the commentary"
    },
    {
      "Behaviour category": "Softening (curve C)",
      "Effective period as displacement grows": "Short at first (high initial stiffness), then longer at higher displacement",
      "Effect beyond the design displacement": "Superstructure force demand is reduced while isolation-system displacement demand increases, compared with an equivalent linear system",
      "Treatment in the standard": "Not excluded by the commentary"
    },
    {
      "Behaviour category": "Purely sliding without restoring force (curve D)",
      "Effective period as displacement grows": "Lengthens with increasing displacement",
      "Effect beyond the design displacement": "Loads on the superstructure remain constant; total displacement from repeated cycles depends on the ground motion and may exceed the design displacement",
      "Treatment in the standard": "No increasing resistance or re-centring; procedures cannot be applied and use is prohibited"
    }
  ],
  "sources": [
    {
      "title": "FEMA P-1050-1 (2015): NEHRP Recommended Seismic Provisions, Part 2 Commentary, C17.1",
      "url": "https://www.wbdg.org/FFC/DHS/fema_p_1051_pt1and2_2015.pdf",
      "accessed": "2026-11-20"
    }
  ]
}