{
  "name": "Countable colony ranges per pour plate by standards body, and the CFU/mL conversion factor they imply at 1 mL inoculum",
  "description": "Countable colony range per pour plate as attributed by the FDA BAM Chapter 3 (January 2026 edition) to USDA, AOAC, APHA and ISO, with BAM's own adopted range; the CFU/mL values are derived with the BAM formula V = dilution ratio x inoculum, R = N / V, for a 1:100 dilution and 1 mL inoculum.",
  "page": "https://casrai.org/guides/serial-dilution-technique-how-to-calculate",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T07:41:28Z",
  "temporalCoverage": "2025/2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Body or method",
      "unit": "",
      "description": ""
    },
    {
      "name": "Lower limit",
      "unit": "colonies per plate",
      "description": ""
    },
    {
      "name": "Upper limit",
      "unit": "colonies per plate",
      "description": ""
    },
    {
      "name": "CFU/mL at lower limit (1:100 dilution, 1 mL plated)",
      "unit": "CFU/mL",
      "description": ""
    },
    {
      "name": "CFU/mL at upper limit (1:100 dilution, 1 mL plated)",
      "unit": "CFU/mL",
      "description": ""
    }
  ],
  "rows": [
    {
      "Body or method": "FDA BAM Ch. 3 (adopted, Jan 2026)",
      "Lower limit": 15,
      "Upper limit": 300,
      "CFU/mL at lower limit (1:100 dilution, 1 mL plated)": 1500,
      "CFU/mL at upper limit (1:100 dilution, 1 mL plated)": 30000
    },
    {
      "Body or method": "ISO (as cited in BAM)",
      "Lower limit": 15,
      "Upper limit": 300,
      "CFU/mL at lower limit (1:100 dilution, 1 mL plated)": 1500,
      "CFU/mL at upper limit (1:100 dilution, 1 mL plated)": 30000
    },
    {
      "Body or method": "USDA (as cited in BAM)",
      "Lower limit": 30,
      "Upper limit": 300,
      "CFU/mL at lower limit (1:100 dilution, 1 mL plated)": 3000,
      "CFU/mL at upper limit (1:100 dilution, 1 mL plated)": 30000
    },
    {
      "Body or method": "AOAC (as cited in BAM)",
      "Lower limit": 30,
      "Upper limit": 300,
      "CFU/mL at lower limit (1:100 dilution, 1 mL plated)": 3000,
      "CFU/mL at upper limit (1:100 dilution, 1 mL plated)": 30000
    },
    {
      "Body or method": "APHA (as cited in BAM)",
      "Lower limit": 25,
      "Upper limit": 250,
      "CFU/mL at lower limit (1:100 dilution, 1 mL plated)": 2500,
      "CFU/mL at upper limit (1:100 dilution, 1 mL plated)": 25000
    }
  ],
  "sources": [
    {
      "title": "FDA Bacteriological Analytical Manual, Chapter 3: Aerobic Plate Count (January 2026)",
      "url": "https://www.fda.gov/food/laboratory-methods-food/bam-chapter-3-aerobic-plate-count",
      "accessed": "2026-11-14"
    }
  ]
}