  "name": "Serial number restoration methods and evidence limits",
  "description": "Original qualitative comparison compiled from Washington and Maine laboratory methods, a 2014 NIJ-sponsored magneto-optical evaluation and NIST’s 2015 EBSD experiment. Rows distinguish the observed signal, applicability limits and source context; they are not a ranking or a universal recovery-performance specification.",
  "page": "https://casrai.org/guides/serial-number-restoration",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-16T20:53:59Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Approach",
      "unit": "",
      "description": ""
    },
    {
      "name": "Signal or principle",
      "unit": "",
      "description": ""
    },
    {
      "name": "Material or geometry condition",
      "unit": "",
      "description": ""
    },
    {
      "name": "Evidence context",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Approach": "Chemical etching",
      "Signal or principle": "Material differences revealed by chemical reaction",
      "Material or geometry condition": "Etchant selected for the metal; surviving deformation matters",
      "Evidence context": "Laboratory procedure; changes the examined surface",
      "Source": "Washington State Patrol, revision 15, sections 2.1, 2.3 and 2.5"
    },
    {
      "Approach": "Magnetic particle inspection",
      "Signal or principle": "Particles reveal magnetic-field disturbances",
      "Material or geometry condition": "Ferrous material; visualization may be difficult",
      "Evidence context": "Described as nondestructive in laboratory methods",
      "Source": "Washington State Patrol, revision 15, sections 2.8–2.9; Maine FA-M001, section 6.8"
    },
    {
      "Approach": "Magneto-optical sensing",
      "Signal or principle": "Faraday-effect visualization of magnetic distribution",
      "Material or geometry condition": "Ferromagnetic material; evaluated configuration required contact and planar surfaces",
      "Evidence context": "2014 evaluation; favorable comparisons limited to tested samples",
      "Source": "NIJ, NCJ 245487"
    },
    {
      "Approach": "Electron backscatter diffraction",
      "Signal or principle": "SEM diffraction pattern-quality maps reveal crystal deformation",
      "Material or geometry condition": "2015 demonstration used removed X stamps in stainless steel",
      "Evidence context": "Experimental demonstration; relative effectiveness was unresolved",
      "Source": "NIST, February 11, 2015 research account"
    }
  ],
  "sources": [
    {
      "title": "Washington State Patrol Firearms/Toolmarks Technical Procedures Manual, revision 15",
      "url": "https://wsp.wa.gov/wp-content/uploads/2025/04/FATM_Technical_Procedures_Revision_15.pdf",
      "accessed": "2026-11-16"
    },
    {
      "title": "Maine State Police Serial Number Restoration Methods, revision 2.0",
      "url": "https://www.maine.gov/dps/msp/sites/maine.gov.dps.msp/files/inline-files/Serial%20Number%20Restoration%20Methods_1.pdf",
      "accessed": "2026-11-16"
    },
    {
      "title": "NIJ Performance Evaluation and Utility Assessment of Magneto-Optical Sensor Technology, NCJ 245487",
      "url": "https://nij.ojp.gov/library/publications/performance-evaluation-and-utility-assessment-magneto-optical-sensor",
      "accessed": "2026-11-16"
    },
    {
      "title": "NIST Shows Crystal Pattern Mapping Can Recover Obliterated Serial Numbers in Metals",
      "url": "https://www.nist.gov/news-events/news/2015/02/nist-shows-crystal-pattern-mapping-can-recover-obliterated-serial-numbers",
      "accessed": "2026-11-16"
    }
  ]
}