  "name": "Shock response spectrum settings across three software references",
  "description": "Original compilation of documented damping, frequency-grid and peak-selection settings from MathWorks srs, the SIGVIEW manual and Siemens Simcenter Testlab guidance. Entries describe the cited implementations; options and defaults are labeled separately.",
  "page": "https://casrai.org/guides/shock-response-spectrum",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-16T21:56:34Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Software reference",
      "unit": "",
      "description": ""
    },
    {
      "name": "Damping documentation",
      "unit": "",
      "description": ""
    },
    {
      "name": "Frequency-grid documentation",
      "unit": "",
      "description": ""
    },
    {
      "name": "Peak or interval documentation",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Software reference": "MathWorks srs (R2026b)",
      "Damping documentation": "Default Q = 10; damping ratio 0.05",
      "Frequency-grid documentation": "Default 1/6 octave; lower Fs/(3*2^15), upper Fs/24",
      "Peak or interval documentation": "Default full response and maximax; primary/residual segments and signed peaks are options",
      "Source": "https://www.mathworks.com/help/signal/ref/srs.html"
    },
    {
      "Software reference": "SIGVIEW SRS",
      "Damping documentation": "Q = 10 corresponds to 5% relative damping",
      "Frequency-grid documentation": "Options: 1/24, 1/12, 1/6, 1/3 octave or linear; configurable minimum and maximum frequencies",
      "Peak or interval documentation": "Peak-detection options control detection of instantaneous acceleration peaks",
      "Source": "https://sigview.com/help/ShockResponseSpectrumSRS.html"
    },
    {
      "Software reference": "Siemens Simcenter Testlab",
      "Damping documentation": "User-set Q; typical Q = 10 corresponds to 5% critical damping",
      "Frequency-grid documentation": "Points per octave range 1 to 48; typical value 6",
      "Peak or interval documentation": "Maximax mapping: Instance = Maximum, Amplitude = Absolute",
      "Source": "https://community.sw.siemens.com/articles/en_US/Knowledge/shock-response-spectrum-srs"
    }
  ],
  "sources": [
    {
      "title": "MathWorks: srs — Shock response spectrum",
      "url": "https://www.mathworks.com/help/signal/ref/srs.html",
      "accessed": "2026-11-16"
    },
    {
      "title": "SignalLab: SIGVIEW User Manual — Shock Response Spectrum (SRS)",
      "url": "https://sigview.com/help/ShockResponseSpectrumSRS.html",
      "accessed": "2026-11-16"
    },
    {
      "title": "Siemens: Shock Response Spectrum (SRS)",
      "url": "https://community.sw.siemens.com/articles/en_US/Knowledge/shock-response-spectrum-srs",
      "accessed": "2026-11-16"
    }
  ]
}