  "name": "Continuous SMB vs Batch Preparative Chromatography Performance Comparison",
  "description": "Comparative empirical operational benchmarks, solvent consumption, resin utilization, and productivity multipliers contrasting continuous simulated moving bed (SMB) chromatography against traditional single-column batch preparative HPLC across published pharmaceutical, biochemical, and specialty chemical separation processes.",
  "page": "https://casrai.org/guides/smb-chromatography",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-16T16:20:00Z",
  "temporalCoverage": "1970-2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Separation Application",
      "unit": "",
      "description": "Target binary separation or process domain"
    },
    {
      "name": "Column Setup",
      "unit": "",
      "description": "Total column count and zone distribution configuration"
    },
    {
      "name": "Solvent Consumption Reduction",
      "unit": "%",
      "description": "Relative mobile phase reduction compared to batch preparative HPLC"
    },
    {
      "name": "Productivity Multiplier",
      "unit": "fold",
      "description": "Ratio of SMB specific throughput to batch preparative throughput"
    },
    {
      "name": "Stationary Phase Savings",
      "unit": "%",
      "description": "Reduction in required resin/adsorbent volume for equivalent throughput"
    },
    {
      "name": "Typical Product Purity",
      "unit": "%",
      "description": "Reported target compound purity achieved in continuous steady state"
    },
    {
      "name": "Typical Product Recovery",
      "unit": "%",
      "description": "Reported percentage of target solute recovered in product stream"
    }
  ],
  "rows": [
    {
      "Separation Application": "Chiral API Enantiomer Resolution",
      "Column Setup": "8 columns (2-2-2-2)",
      "Solvent Consumption Reduction": 85,
      "Productivity Multiplier": 3.8,
      "Stationary Phase Savings": 65,
      "Typical Product Purity": 99.2,
      "Typical Product Recovery": 98.5
    },
    {
      "Separation Application": "Cannabinoid Depletion (CBD/THC)",
      "Column Setup": "4 columns (1-1-1-1)",
      "Solvent Consumption Reduction": 92,
      "Productivity Multiplier": 1.2,
      "Stationary Phase Savings": 50,
      "Typical Product Purity": 97.8,
      "Typical Product Recovery": 98.8
    },
    {
      "Separation Application": "Carbohydrate Fractionation (Glucose/Fructose)",
      "Column Setup": "12 columns (3-3-3-3)",
      "Solvent Consumption Reduction": 75,
      "Productivity Multiplier": 4.5,
      "Stationary Phase Savings": 60,
      "Typical Product Purity": 98,
      "Typical Product Recovery": 95
    },
    {
      "Separation Application": "Petrochemical Xylene Isomers (p-Xylene)",
      "Column Setup": "24 beds rotary",
      "Solvent Consumption Reduction": 80,
      "Productivity Multiplier": 5,
      "Stationary Phase Savings": 70,
      "Typical Product Purity": 99.7,
      "Typical Product Recovery": 96.5
    },
    {
      "Separation Application": "Recombinant Protein / Biologic Capture",
      "Column Setup": "4 columns (1-1-1-1)",
      "Solvent Consumption Reduction": 70,
      "Productivity Multiplier": 2.5,
      "Stationary Phase Savings": 45,
      "Typical Product Purity": 98.5,
      "Typical Product Recovery": 94
    }
  ],
  "sources": [
    {
      "title": "Simulated moving bed chromatography for the separation of enantiomers",
      "url": "https://doi.org/10.1016/j.chroma.2008.10.075",
      "accessed": "2026-11-14"
    },
    {
      "title": "Continuous Depletion of Tetrahydrocannabinol From Cannabis Extract Through Simulated Moving Bed Chromatography Using Green Mobile Phase",
      "url": "https://doi.org/10.1002/jssc.70175",
      "accessed": "2026-11-14"
    },
    {
      "title": "Counter-current and simulated counter-current adsorption separation processes",
      "url": "https://doi.org/10.1016/0009-2509(89)85001-7",
      "accessed": "2026-11-14"
    },
    {
      "title": "KNAUER AZURA SMB Systems: Preparative and Continuous Liquid Chromatography",
      "url": "https://www.knauer.net/en/Systems-Solutions/Preparative-HPLC/Simulated-Moving-Bed-SMB",
      "accessed": "2026-11-14"
    }
  ]
}