  "name": "Soil Organic Carbon Analytical Methods Comparison",
  "description": "Comparative specifications of standard laboratory methods for measuring soil organic carbon, compiled from ISO standards, FAO GLOSOLAN SOPs, and USDA-NRCS analytical manuals.",
  "page": "https://casrai.org/guides/soil-organic-carbon",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-19T12:30:00Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Method Name",
      "unit": "",
      "description": "Standard analytical technique or protocol designation"
    },
    {
      "name": "Standard Reference",
      "unit": "",
      "description": "Primary standard specification or operating procedure"
    },
    {
      "name": "Operational Principle",
      "unit": "",
      "description": "Underlying chemical reaction or physical detection mechanism"
    },
    {
      "name": "Operating Temperature",
      "unit": "°C",
      "description": "Nominal thermal processing condition"
    },
    {
      "name": "Limit of Detection",
      "unit": "g/kg",
      "description": "Typical analytical quantification limit in dry soil"
    },
    {
      "name": "Recovery Rate",
      "unit": "%",
      "description": "Typical analytical carbon recovery efficiency without correction factor"
    },
    {
      "name": "Carbonate Interference",
      "unit": "",
      "description": "Vulnerability to inorganic carbon presence and required pre-treatment"
    },
    {
      "name": "Hazardous Waste Profile",
      "unit": "",
      "description": "Chemical hazards and laboratory waste generation profile"
    }
  ],
  "rows": [
    {
      "Method Name": "High-Temperature Dry Combustion (Dumas)",
      "Standard Reference": "ISO 10694:1995 / GLOSOLAN-SOP-03",
      "Operational Principle": "Catalytic combustion in pure O2 with NDIR or TCD detection",
      "Operating Temperature": 1050,
      "Limit of Detection": 0.1,
      "Recovery Rate": 99.5,
      "Carbonate Interference": "Measures total carbon; requires acid pre-treatment or separate TIC determination",
      "Hazardous Waste Profile": "None; produces CO2, H2O, N2 gas effluent"
    },
    {
      "Method Name": "Classical Walkley-Black Wet Oxidation",
      "Standard Reference": "GLOSOLAN-SOP-02 / Walkley & Black (1934)",
      "Operational Principle": "Sulfochromic oxidation by K2Cr2O7 and H2SO4 with ferrous titration",
      "Operating Temperature": 120,
      "Limit of Detection": 0.5,
      "Recovery Rate": 76,
      "Carbonate Interference": "Minimal direct carbonate interference; partially oxidizes active carbon only",
      "Hazardous Waste Profile": "High; produces toxic hexavalent chromium (Cr VI) and concentrated acidic waste"
    },
    {
      "Method Name": "Modified Sulfochromic Oxidation (Heated)",
      "Standard Reference": "ISO 14235:1998",
      "Operational Principle": "External heating sulfochromic digestion with spectrophotometry at 585-600 nm",
      "Operating Temperature": 135,
      "Limit of Detection": 0.2,
      "Recovery Rate": 92,
      "Carbonate Interference": "Minimal carbonate interference; higher recovery than unheated digestion",
      "Hazardous Waste Profile": "High; produces hexavalent and trivalent chromium waste requiring specialized treatment"
    },
    {
      "Method Name": "Loss-on-Ignition (LOI)",
      "Standard Reference": "USDA-NRCS SSIR 42 Method 4H1a",
      "Operational Principle": "Gravimetric mass loss following thermal oxidation in muffle furnace",
      "Operating Temperature": 400,
      "Limit of Detection": 1,
      "Recovery Rate": 100,
      "Carbonate Interference": "Significant error if temp >430°C due to carbonate breakdown; clay structural water loss",
      "Hazardous Waste Profile": "None; thermal flue gas only"
    },
    {
      "Method Name": "Diffuse Reflectance Mid-Infrared Spectroscopy (MIR)",
      "Standard Reference": "GLOSOLAN-SOP-Spectroscopy / FAO (2020)",
      "Operational Principle": "Vibrational spectroscopy of fundamental fundamental C-H and C-O bands (4000-400 cm-1)",
      "Operating Temperature": 25,
      "Limit of Detection": 0.5,
      "Recovery Rate": 95,
      "Carbonate Interference": "Separate spectral absorption features differentiate organic C from carbonate minerals",
      "Hazardous Waste Profile": "None; dry physical grinding only, reagent-free screening"
    }
  ],
  "sources": [
    {
      "title": "ISO 10694:1995 Soil Quality - Determination of Organic and Total Carbon after Dry Combustion",
      "url": "https://www.iso.org/standard/18782.html",
      "accessed": "2026-11-14"
    },
    {
      "title": "FAO GLOSOLAN-SOP-03: Soil Total Carbon - Dumas Dry Combustion Method",
      "url": "https://www.fao.org/global-soil-partnership/glosolan/soil-analysis/standard-operating-procedures/en/",
      "accessed": "2026-11-14"
    },
    {
      "title": "FAO GLOSOLAN-SOP-02: Soil Organic Carbon - Walkley-Black Method",
      "url": "https://www.fao.org/global-soil-partnership/glosolan/soil-analysis/standard-operating-procedures/en/",
      "accessed": "2026-11-14"
    },
    {
      "title": "ISO 14235:1998 Soil Quality - Determination of Organic Carbon by Sulfochromic Oxidation",
      "url": "https://www.iso.org/standard/23472.html",
      "accessed": "2026-11-14"
    },
    {
      "title": "USDA-NRCS Kellogg Soil Survey Laboratory Methods Manual, SSIR No. 42",
      "url": "https://www.nrcs.usda.gov/resources/guides-and-instructions/kellogg-soil-survey-laboratory-methods-manual",
      "accessed": "2026-11-14"
    }
  ]
}