  "name": "SRB assay parameters reported in three published protocols",
  "description": "Side-by-side comparison of cell format, fixation, staining, washing, dye extraction, read wavelength and linearity claims for the sulforhodamine B assay, compiled from the abstracts and full text of three published sources.",
  "page": "https://casrai.org/guides/sulforhodamine-b",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-16T14:30:00Z",
  "temporalCoverage": "1990/2016",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Parameter",
      "unit": "",
      "description": ""
    },
    {
      "name": "Skehan et al. 1990 (J Natl Cancer Inst)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Vichai and Kirtikara 2006 (Nat Protoc)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Orellana and Kasinski 2016 (Bio-protocol)",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Parameter": "Cell type and format",
      "Skehan et al. 1990 (J Natl Cancer Inst)": "Adherent and suspension cultures, 96-well plates",
      "Vichai and Kirtikara 2006 (Nat Protoc)": "Adherent cells, 96-well plates",
      "Orellana and Kasinski 2016 (Bio-protocol)": "Adherent cells, 96- and 384-well plates"
    },
    {
      "Parameter": "Fixative",
      "Skehan et al. 1990 (J Natl Cancer Inst)": "TCA",
      "Vichai and Kirtikara 2006 (Nat Protoc)": "10% (wt/vol) TCA",
      "Orellana and Kasinski 2016 (Bio-protocol)": "Cold 50% TCA added to medium (25 µl per well, 96-well), 1 h at 4 °C, not mixed"
    },
    {
      "Parameter": "Stain",
      "Skehan et al. 1990 (J Natl Cancer Inst)": "0.4% (wt/vol) SRB in 1% acetic acid, 30 min",
      "Vichai and Kirtikara 2006 (Nat Protoc)": "SRB, 30 min",
      "Orellana and Kasinski 2016 (Bio-protocol)": "0.04% SRB in 1% acetic acid (50 µl), room temperature, 1 h"
    },
    {
      "Parameter": "Wash after staining",
      "Skehan et al. 1990 (J Natl Cancer Inst)": "4 washes with 1% acetic acid",
      "Vichai and Kirtikara 2006 (Nat Protoc)": "Repeated washes with 1% acetic acid",
      "Orellana and Kasinski 2016 (Bio-protocol)": "4 rinses with 1% acetic acid"
    },
    {
      "Parameter": "Dye extraction",
      "Skehan et al. 1990 (J Natl Cancer Inst)": "10 mM unbuffered Tris base",
      "Vichai and Kirtikara 2006 (Nat Protoc)": "10 mM Tris base",
      "Orellana and Kasinski 2016 (Bio-protocol)": "10 mM Tris base pH 10.5 (50-100 µl), orbital shaker about 10 min"
    },
    {
      "Parameter": "Read wavelength",
      "Skehan et al. 1990 (J Natl Cancer Inst)": "564 nm (signal-to-noise about 1.5 at 1,000 cells per well)",
      "Vichai and Kirtikara 2006 (Nat Protoc)": "510 nm",
      "Orellana and Kasinski 2016 (Bio-protocol)": "510 nm"
    },
    {
      "Parameter": "Reported linearity or key claim",
      "Skehan et al. 1990 (J Natl Cancer Inst)": "Linear with cell number and with Lowry and Bradford protein values",
      "Vichai and Kirtikara 2006 (Nat Protoc)": "Linear over a 20-fold range of cell numbers",
      "Orellana and Kasinski 2016 (Bio-protocol)": "Proxy for cell mass; does not rely on metabolic activity"
    }
  ],
  "sources": [
    {
      "title": "Skehan et al. 1990, J Natl Cancer Inst 82(13):1107-12",
      "url": "https://pubmed.ncbi.nlm.nih.gov/2359136/",
      "accessed": "2026-11-15"
    },
    {
      "title": "Vichai and Kirtikara 2006, Nat Protoc 1(3):1112-6",
      "url": "https://pubmed.ncbi.nlm.nih.gov/17406391/",
      "accessed": "2026-11-15"
    },
    {
      "title": "Orellana and Kasinski 2016, Bio-protocol 6(21):e1984",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5448418/",
      "accessed": "2026-11-15"
    }
  ]
}