{
  "name": "SPR kinetic experiment design and fit-quality thresholds from Cytiva and Bio-Rad documentation",
  "description": "Numeric design and fit-quality guidance for surface plasmon resonance experiments, compiled from Cytiva's Biacore help files and Bio-Rad's ProteOn XPR36 data-analysis guide. Each row gives the lower and upper value stated by the source and the experiment type it applies to; open-ended limits are left blank.",
  "page": "https://casrai.org/guides/surface-plasmon-resonance-binding-kinetics-kd-calculation",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-21T18:03:35Z",
  "temporalCoverage": "2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Parameter",
      "unit": "",
      "description": ""
    },
    {
      "name": "Experiment type",
      "unit": "",
      "description": ""
    },
    {
      "name": "Lower value",
      "unit": "",
      "description": ""
    },
    {
      "name": "Upper value",
      "unit": "",
      "description": ""
    },
    {
      "name": "Unit",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Parameter": "Maximum analyte response (Rmax) target",
      "Experiment type": "Kinetics (Biacore)",
      "Lower value": 10,
      "Upper value": 30,
      "Unit": "RU",
      "Source": "Cytiva Biacore help: How much ligand should I immobilize"
    },
    {
      "Parameter": "Maximum analyte response (Rmax), recommended ceiling",
      "Experiment type": "Kinetics (ProteOn XPR36)",
      "Lower value": "n/a",
      "Upper value": 200,
      "Unit": "RU",
      "Source": "Bio-Rad ProteOn XPR36 data analysis guide"
    },
    {
      "Parameter": "Immobilized ligand level, typical for 50,000-150,000 Da ligands",
      "Experiment type": "Concentration analysis (Biacore)",
      "Lower value": 10000,
      "Upper value": 15000,
      "Unit": "RU",
      "Source": "Cytiva Biacore help: How much ligand should I immobilize"
    },
    {
      "Parameter": "Immobilized ligand level, macromolecular ligand and analyte",
      "Experiment type": "Concentration analysis (Biacore)",
      "Lower value": 10000,
      "Upper value": 20000,
      "Unit": "RU",
      "Source": "Cytiva Biacore help: How much ligand should I immobilize"
    },
    {
      "Parameter": "Theoretical capacity: 100,000 Da ligand, 50,000 Da analyte, 5,000 RU immobilized, 1:1, fully active",
      "Experiment type": "Worked example (Biacore)",
      "Lower value": 2500,
      "Upper value": 2500,
      "Unit": "RU",
      "Source": "Cytiva Biacore help: How much ligand should I immobilize"
    },
    {
      "Parameter": "Measurable dissociation rate constant (kd)",
      "Experiment type": "Kinetics (Biacore)",
      "Lower value": 0.00001,
      "Upper value": 0.1,
      "Unit": "s^-1",
      "Source": "Cytiva Biacore help: How does kinetic fitting work"
    },
    {
      "Parameter": "Chi2 (empirical ceiling as share of Rmax)",
      "Experiment type": "Kinetic fit quality (ProteOn)",
      "Lower value": "n/a",
      "Upper value": 10,
      "Unit": "% of Rmax",
      "Source": "Bio-Rad ProteOn XPR36 data analysis guide"
    },
    {
      "Parameter": "Signal-to-noise ratio, typical minimum",
      "Experiment type": "Kinetics (ProteOn)",
      "Lower value": 3,
      "Upper value": "n/a",
      "Unit": "ratio",
      "Source": "Bio-Rad ProteOn XPR36 data analysis guide"
    },
    {
      "Parameter": "Baseline noise, ProteOn XPR36",
      "Experiment type": "Kinetics (ProteOn)",
      "Lower value": 1,
      "Upper value": 1,
      "Unit": "RU",
      "Source": "Bio-Rad ProteOn XPR36 data analysis guide"
    }
  ],
  "sources": [
    {
      "title": "Biacore help: How much ligand should I immobilize?",
      "url": "https://info.cytivalifesciences.com/Biacore-help-files_How-much-ligand-should-I-immobilize.html",
      "accessed": "2026-11-21"
    },
    {
      "title": "Biacore help: How does kinetic fitting work?",
      "url": "https://info.cytivalifesciences.com/Biacore-help-files_How-does-kinetic-fitting-work.html",
      "accessed": "2026-11-21"
    },
    {
      "title": "Guide to SPR data analysis on the ProteOn XPR36 system (Bio-Rad Bioradiations)",
      "url": "https://www.bioradiations.com/guide-to-spr-data-analysis-on-the-proteon-xpr36-system/",
      "accessed": "2026-11-21"
    }
  ]
}