  "name": "Early medical telemanipulator systems and the roles two reviews assign them",
  "description": "Compiled by CASRAI from two open-access reviews of medical telerobotics (Avgousti et al. 2016; Das et al. 2023): each system, the year or period the sources give, its master-slave role and the distance class it illustrates.",
  "page": "https://casrai.org/guides/telemanipulator",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-21T05:45:30Z",
  "temporalCoverage": "1995/2023",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "System",
      "unit": "",
      "description": ""
    },
    {
      "name": "Year or period given in sources",
      "unit": "",
      "description": ""
    },
    {
      "name": "Role in the source",
      "unit": "",
      "description": ""
    },
    {
      "name": "Distance class illustrated",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "System": "PUMA 560",
      "Year or period given in sources": "Nearly 40 years before 2023",
      "Role in the source": "Robot used for a stereotaxic brain biopsy",
      "Distance class illustrated": "Not stated"
    },
    {
      "System": "AESOP",
      "Year or period given in sources": "About 1995; FDA 510(k) decisions 1996-05-03 (K960655) and 1997-12-19 (K972699)",
      "Role in the source": "Laparoscopic camera holder; first FDA-approved; later voice-controlled with seven degrees of freedom",
      "Distance class illustrated": "Not stated"
    },
    {
      "System": "ZEUS",
      "Year or period given in sources": "1998",
      "Role in the source": "Master-slave surgical system; two surgical arms with four degrees of freedom each",
      "Distance class illustrated": "Long distance (New York to Strasbourg, 2001)"
    },
    {
      "System": "da Vinci Surgical System",
      "Year or period given in sources": "About 1995",
      "Role in the source": "Master-slave surgical system",
      "Distance class illustrated": "Short distance over a local area network"
    },
    {
      "System": "Melody (AdEchoTech)",
      "Year or period given in sources": "Deployed by 2023",
      "Role in the source": "Telerobotic ultrasound with a patient-site manipulator holding the probe",
      "Distance class illustrated": "Remote diagnostic"
    }
  ],
  "sources": [
    {
      "title": "openFDA device 510(k): AESOP records K960655, K972699",
      "url": "https://api.fda.gov/device/510k.json?search=device_name:%22aesop%22&limit=3",
      "accessed": "2026-11-21"
    },
    {
      "title": "Medical telerobotic systems: current status and future trends",