  "name": "Ten States Standards (2014 wastewater edition): treatment plant laboratory provisions by category",
  "description": "Compares what Sections 58.2, 58.3 and 58.4 of the GLUMRB Recommended Standards for Wastewater Facilities (2014 Edition) say about space, balance, fume hoods and eyewash provisions for the three plant laboratory categories. Compiled by reading the standards text directly; 'not specified' means the section is silent.",
  "page": "https://casrai.org/guides/ten-states-standards",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-24T08:10:00Z",
  "temporalCoverage": "2014",
  "spatialCoverage": "Illinois, Indiana, Iowa, Michigan, Minnesota, Missouri, New York, Ohio, Ontario, Pennsylvania, Wisconsin",
  "columns": [
    {
      "name": "Laboratory category",
      "unit": "",
      "description": ""
    },
    {
      "name": "Typical testing (Section 58.1)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Floor space guidance",
      "unit": "",
      "description": ""
    },
    {
      "name": "Analytical balance",
      "unit": "",
      "description": ""
    },
    {
      "name": "Fume hoods",
      "unit": "",
      "description": ""
    },
    {
      "name": "Eyewash and safety shower",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Laboratory category": "Category I (Section 58.2)",
      "Typical testing (Section 58.1)": "Basic operational testing, typically pH, temperature, dissolved oxygen",
      "Floor space guidance": "Up to 150 sq ft (14 m2) should be adequate",
      "Analytical balance": "Not specified in 58.2",
      "Fume hoods": "Not specified in 58.2",
      "Eyewash and safety shower": "Not specified in 58.2"
    },
    {
      "Laboratory category": "Category II (Section 58.3)",
      "Typical testing (Section 58.1)": "Operational and permit tests including BOD, suspended solids, bacterial analysis",
      "Floor space guidance": "Minimum approx. 300 sq ft (28 m2); adequate bench space for each analyst",
      "Analytical balance": "Shall be provided: automatic digital single pan, 0.1 mg sensitivity",
      "Fume hoods": "Shall be provided where work produces noxious fumes",
      "Eyewash and safety shower": "Shall be provided; no more than 25 ft (7.6 m) from hazardous chemical exposure"
    },
    {
      "Laboratory category": "Category III (Section 58.4)",
      "Typical testing (Section 58.1)": "Operational, permit, industrial pretreatment and multiple plant testing",
      "Floor space guidance": "No fixed area; based on evaluation of complexity, volume and variety of analyses; bench top at least 35 percent of floor for less complicated needs",
      "Analytical balance": "Shall be provided: automatic digital single pan, 0.1 mg sensitivity",
      "Fume hoods": "Shall be provided where work produces noxious fumes; canopy hoods over heat-releasing equipment",
      "Eyewash and safety shower": "Shall be provided; no more than 25 ft (7.6 m) from hazardous chemical exposure"
    }
  ],
  "sources": [
    {
      "title": "GLUMRB Recommended Standards for Wastewater Facilities, 2014 Edition",
      "url": "https://www.health.mn.gov/communities/environment/water/docs/tenstates/tenstatestan2014.pdf",
      "accessed": "2026-11-12"
    }
  ]
}