  "name": "TLC run parameters and eluent guidance compiled from teaching-lab and university sources",
  "description": "Numeric TLC practice parameters (baseline, solvent depth, stop distance, Rf target, additive level, observed Rf spread) compiled from York Chemistry Teaching Labs, Nichols LibreTexts and University of Rochester guidance. Values are as stated by each source, not averaged.",
  "page": "https://casrai.org/guides/thin-layer-chromatography-running-a-plate-calculating-rf",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-20T02:35:20Z",
  "temporalCoverage": "2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Parameter",
      "unit": "",
      "description": ""
    },
    {
      "name": "Value (low)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Value (high)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Unit",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Parameter": "Baseline height above plate bottom",
      "Value (low)": 1,
      "Value (high)": 1,
      "Unit": "cm",
      "Source": "York general procedure"
    },
    {
      "Parameter": "Mobile phase depth in chamber",
      "Value (low)": 0.5,
      "Value (high)": 0.5,
      "Unit": "cm",
      "Source": "York general procedure"
    },
    {
      "Parameter": "Mobile phase volume in a 250 mL beaker",
      "Value (low)": 10,
      "Value (high)": 10,
      "Unit": "mL",
      "Source": "York general procedure"
    },
    {
      "Parameter": "Distance of front from top edge when plate is removed",
      "Value (low)": 1,
      "Value (high)": 2,
      "Unit": "cm",
      "Source": "York general procedure"
    },
    {
      "Parameter": "Distance of front from top edge when plate is removed",
      "Value (low)": 0.5,
      "Value (high)": 0.5,
      "Unit": "cm",
      "Source": "LibreTexts 2.3C"
    },
    {
      "Parameter": "Rf target for flash-column eluent",
      "Value (low)": 0.3,
      "Value (high)": 0.3,
      "Unit": "Rf (dimensionless)",
      "Source": "Rochester flash column"
    },
    {
      "Parameter": "Triethylamine or pyridine additive for basic compounds",
      "Value (low)": 0.1,
      "Value (high)": 0.1,
      "Unit": "percent",
      "Source": "Rochester flash column"
    },
    {
      "Parameter": "Acetophenone Rf, 6:1 hexanes:EtOAc, four runs (0.33, 0.38, 0.35, 0.37)",
      "Value (low)": 0.33,
      "Value (high)": 0.38,
      "Unit": "Rf (dimensionless)",
      "Source": "LibreTexts 2.3C"
    }
  ],
  "sources": [
    {
      "title": "York Chemistry Teaching Labs: TLC general procedure",
      "url": "https://chemtl.york.ac.uk/techniques/reaction-techniques/tlc/general-procedure",
      "accessed": "2026-11-19"
    },
    {
      "title": "LibreTexts: 2.3C The Retention Factor (Nichols)",
      "url": "https://chem.libretexts.org/Bookshelves/Organic_Chemistry/Organic_Chemistry_Lab_Techniques_(Nichols)/02%3A_Chromatography/2.03%3A_Thin_Layer_Chromatography_(TLC)/2.3C%3A_The_Retention_Factor",
      "accessed": "2026-11-19"
    },
    {
      "title": "University of Rochester: How to run a flash column",
      "url": "https://www.chem.rochester.edu/notvoodoo/pages/how_to/flash_column.php",
      "accessed": "2026-11-19"
    }
  ]
}