  "name": "TSS gravimetric test (SM 2540 D): specification and QC values from a state laboratory SOP",
  "description": "Compiled from Georgia EPD laboratory SOP 3-005 Rev. 8 for Standard Methods 2540 D: filter, drying, constant-weight, residue window, holding-time and quality-control values for the total suspended solids test, cross-referenced with the 40 CFR 136.3 Table IB drying temperature.",
  "page": "https://casrai.org/guides/tss-test",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T11:04:14Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Parameter",
      "unit": "",
      "description": ""
    },
    {
      "name": "Value in the SOP",
      "unit": "",
      "description": ""
    },
    {
      "name": "Role in the test",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Parameter": "Filter",
      "Value in the SOP": "47 mm standard glass fiber filter (Whatman 934-AH, Gelman A/E or equivalent)",
      "Role in the test": "Retains the suspended solids"
    },
    {
      "Parameter": "Drying temperature",
      "Value in the SOP": "103-105 C (same in 40 CFR 136.3 Table IB)",
      "Role in the test": "Dries filter and residue"
    },
    {
      "Parameter": "Filter pre-wash",
      "Value in the SOP": "At least 60 mL reagent water",
      "Role in the test": "Removes loose fibres before the tare weight"
    },
    {
      "Parameter": "Filter drying time before weighing",
      "Value in the SOP": "At least 1 h (overnight preferable), then desiccator cooling at least 1 h",
      "Role in the test": "Brings filter to tare weight"
    },
    {
      "Parameter": "Constant-weight criterion",
      "Value in the SOP": "Change below 4% of previous weight or 0.5 mg, whichever is less",
      "Role in the test": "Confirms drying is complete"
    },
    {
      "Parameter": "Balance resolution",
      "Value in the SOP": "0.1 mg, calibration verified each day of use with certified weights",
      "Role in the test": "Weighing"
    },
    {
      "Parameter": "Dried residue window",
      "Value in the SOP": "2.5 to 200 mg",
      "Role in the test": "Below 2.5 mg or above 200 mg with under 1000 mL filtered: corrective action and J-flag"
    },
    {
      "Parameter": "Maximum filtration time",
      "Value in the SOP": "10 minutes",
      "Role in the test": "Longer: restart with clean filter and smaller volume"
    },
    {
      "Parameter": "Practical range",
      "Value in the SOP": "1.0 to 20,000 mg/L",
      "Role in the test": "Applicable concentration range"
    },
    {
      "Parameter": "Sample storage",
      "Value in the SOP": "0-6 C, not frozen, no chemical preservative",
      "Role in the test": "Preservation"
    },
    {
      "Parameter": "Holding time",
      "Value in the SOP": "7 days",
      "Role in the test": "Time allowed to analysis"
    },
    {
      "Parameter": "Method blank",
      "Value in the SOP": "1000 mL reagent water per batch",
      "Role in the test": "Contamination check"
    },
    {
      "Parameter": "Laboratory control sample",
      "Value in the SOP": "Celite 545 stock, 100 mg/L, 100 mL used, per batch of 20; limits 90-110% recovery, RPD 15",
      "Role in the test": "Accuracy check"
    },
    {
      "Parameter": "Sample duplicates",
      "Value in the SOP": "10% of samples (minimum 1 for 1-10 samples, 2 for 11-20); agreement within 5% of average (10% RPD)",
      "Role in the test": "Precision check"
    }
  ],
  "sources": [
    {
      "title": "Georgia EPD Laboratory SOP 3-005 Rev. 8, SM 2540 D Total Suspended Solids",
      "url": "https://epd.georgia.gov/document/document/sop-3-005-rev-8-sm2540d-tsspdf/download",
      "accessed": "2026-11-15"
    },
    {
      "title": "40 CFR 136.3 Table IB (Cornell LII)",
      "url": "https://www.law.cornell.edu/cfr/text/40/136.3",
      "accessed": "2026-11-15"
    }
  ]
}