  "name": "Pipette washer designs: published capacities, cycle figures and connections",
  "description": "Compiled from the Alconox technical note, two Lab Manager articles supplied by Miele and the Labconco ScrubAir article. Each row is a named washer or basket with the capacity, length limit, cycle time and water figure stated by that source. Figures are manufacturer claims.",
  "page": "https://casrai.org/guides/what-is-a-pipette-washer",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-19T23:24:11Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Washer or basket",
      "unit": "",
      "description": ""
    },
    {
      "name": "Pipettes per load",
      "unit": "pipettes",
      "description": ""
    },
    {
      "name": "Maximum pipette length",
      "unit": "inches",
      "description": ""
    },
    {
      "name": "Stated figure",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Washer or basket": "Labconco ScrubAir (standard)",
      "Pipettes per load": 60,
      "Maximum pipette length": "",
      "Stated figure": "Wash and dry just under 5 h; as little as 12.5 L water"
    },
    {
      "Washer or basket": "Labconco ScrubAir (heated)",
      "Pipettes per load": 60,
      "Maximum pipette length": "",
      "Stated figure": "Wash and dry 3.25 h"
    },
    {
      "Washer or basket": "Miele A303 insert",
      "Pipettes per load": 98,
      "Maximum pipette length": 18,
      "Stated figure": "Miele wash runtimes 60-90 min"
    },
    {
      "Washer or basket": "Miele A202 insert",
      "Pipettes per load": 38,
      "Maximum pipette length": 21,
      "Stated figure": "Space for other glassware"
    },
    {
      "Washer or basket": "Miele E 404 basket",
      "Pipettes per load": 36,
      "Maximum pipette length": "",
      "Stated figure": "Three rows"
    },
    {
      "Washer or basket": "Miele E 408 basket",
      "Pipettes per load": 96,
      "Maximum pipette length": "",
      "Stated figure": "For washers with HEPA forced-air drying"
    }
  ],
  "sources": [
    {
      "title": "Lab Manager: Getting the Pipette Cleaning Equation Right Every Time",
      "url": "https://www.labmanager.com/getting-the-pipette-cleaning-equation-right-every-time-9132",
      "accessed": "2026-11-19"
    },
    {
      "title": "Lab Manager: Effective Cleaning of Pipettes",
      "url": "https://www.labmanager.com/effective-cleaning-of-pipettes-15686",
      "accessed": "2026-11-19"
    },
    {
      "title": "Labconco: New ScrubAir Pipette Washer/Dryer",
      "url": "https://www.labconco.com/articles/new-scrubair-pipette-washer-dryer",
      "accessed": "2026-11-19"
    }
  ]
}