      "name": "Pipette Class & Operating Mode",
      "unit": "",
      "description": "Pipetting instrument architecture and operational mode"
    },
    {
      "name": "Primary Liquid Target",
      "unit": "",
      "description": "Optimal fluid characteristics for the operating mode"
    },
    {
      "name": "Dynamic Viscosity Limit",
      "unit": "mPa·s",
      "description": "Maximum practical dynamic fluid viscosity threshold"
    },
    {
      "name": "Aspiration Volume Stroke",
      "unit": "",
      "description": "Piston stroke behavior relative to nominal volume"
    },
    {
      "name": "Dispense Piston Stop",
      "unit": "",
      "description": "Plunger or motor position during liquid delivery"
    },
    {
      "name": "Filter Tip Requirement",
      "unit": "",
      "description": "Consumable barrier clearance requirement"
    },
    {
      "name": "Systematic Error at 100 µL",
      "unit": "%",
      "description": "ISO 8655-2 maximum permissible systematic error on water"
    }
  ],
  "rows": [
    {
      "Pipette Class & Operating Mode": "Manual Air-Displacement (Forward Mode)",
      "Primary Liquid Target": "Aqueous solutions and dilute biological buffers",
      "Dynamic Viscosity Limit": 10,
      "Aspiration Volume Stroke": "Nominal set volume (1st stop)",
      "Dispense Piston Stop": "2nd stop (full blowout)",
      "Filter Tip Requirement": "Standard aerosol filter tip",
      "Systematic Error at 100 µL": 0.8
    },
    {
      "Pipette Class & Operating Mode": "Manual Air-Displacement (Reverse Mode)",
      "Primary Liquid Target": "Viscous fluids (glycerol), foaming proteins, detergent solutions",
      "Dynamic Viscosity Limit": 50,
      "Aspiration Volume Stroke": "Nominal volume plus blowout buffer (2nd stop)",
      "Dispense Piston Stop": "1st stop (leaves residual buffer)",
      "Filter Tip Requirement": "Extended-cushion / SafetySpace filter tip",
      "Systematic Error at 100 µL": 1.2
    },
    {
      "Pipette Class & Operating Mode": "Electronic Air-Displacement (Reverse Mode)",
      "Primary Liquid Target": "Volatile solvents, detergents, and repetitive dispensing",
      "Dynamic Viscosity Limit": 50,
      "Aspiration Volume Stroke": "Nominal volume plus automated blowout buffer",
      "Dispense Piston Stop": "Automated primary stop (purge to waste)",
      "Filter Tip Requirement": "Extended-cushion / SafetySpace filter tip",
      "Systematic Error at 100 µL": 1
    },
    {
      "Pipette Class & Operating Mode": "Positive-Displacement Micropipette",
      "Primary Liquid Target": "High-viscosity oils (>50 mPa·s), volatile organics, radioactive reagents",
      "Dynamic Viscosity Limit": 500,
      "Aspiration Volume Stroke": "Direct piston displacement (no air cushion)",
      "Dispense Piston Stop": "Full stroke dispense (direct mechanical expulsion)",
      "Filter Tip Requirement": "Piston-integrated capillary tip (no filter)",
      "Systematic Error at 100 µL": 0.6
    }
  ],
  "sources": [
    {
      "title": "ISO 8655-2:2022 Piston-operated volumetric apparatus — Part 2: Pipettes",
      "url": "https://www.iso.org/standard/76361.html",
      "accessed": "2026-11-14"
    },
    {
      "title": "Eppendorf Research plus and Xplorer Operating Manuals",
      "url": "https://www.eppendorf.com/product-catalog/liquid-handling/manual-liquid-handling/micropipettes/eppendorf-research-plus/",
      "accessed": "2026-11-14"
    },
    {
      "title": "Sartorius Picus 2 Electronic Pipette Operating Instructions",
      "url": "https://www.sartorius.com/en/products/pipetting/electronic-pipettes/picus-2",
      "accessed": "2026-11-14"
    },
    {
      "title": "INTEGRA VIAFLO Electronic Pipettes Operating Instructions",
      "url": "https://www.integra-biosciences.com/united-states/en/electronic-pipettes/viaflo",
      "accessed": "2026-11-14"
    },
    {
      "title": "Mettler Toledo Rainin Pipetting Challenging Liquids Guide",
      "url": "https://www.mt.com/us/en/home/library/guides/rainin-pipettes/pipetting-challenging-liquids.html",
      "accessed": "2026-11-14"
    }
  ]
}