  "name": "Published fill-volume statements for aerobic shake flask culture, by source",
  "description": "Fill-volume recommendations for Erlenmeyer-type shake flasks, compiled from two vendor-authored sources (a 2015 GEN article by an Infors HT product manager and an Infors HT blog post). Each row restates one published statement as a percentage of nominal flask volume, with the purpose the author gives. The sources disagree, so the rows are kept separate rather than averaged.",
  "page": "https://casrai.org/guides/what-is-a-shaker-flask",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-18T02:30:47Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Statement",
      "unit": "",
      "description": "What the source says about fill level"
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    },
    {
      "name": "Lower bound",
      "unit": "% of nominal volume",
      "description": ""
    },
    {
      "name": "Upper bound",
      "unit": "% of nominal volume",
      "description": ""
    },
    {
      "name": "Purpose or context given",
      "unit": "",
      "description": "Why the author gives this fill level"
    }
  ],
  "rows": [
    {
      "Statement": "General ceiling for Erlenmeyer flasks",
      "Source": "GEN, Bruecher (2015)",
      "Lower bound": 0,
      "Upper bound": 30,
      "Purpose or context given": "30% should never be exceeded"
    },
    {
      "Statement": "Common laboratory practice criticised by the author",
      "Source": "GEN, Bruecher (2015)",
      "Lower bound": 50,
      "Upper bound": 50,
      "Purpose or context given": "Considered a poor choice for aerobic cultures"
    },
    {
      "Statement": "Fill level for maximum oxygen transfer",
      "Source": "GEN, Bruecher (2015)",
      "Lower bound": 10,
      "Upper bound": 10,
      "Purpose or context given": "Shaking speed raised as far as shear stress and shaker limits allow; reduces culture volume"
    },
    {
      "Statement": "Usual filling volume for standard Erlenmeyer flasks",
      "Source": "Infors HT blog",
      "Lower bound": 20,
      "Upper bound": 40,
      "Purpose or context given": "Described as usual practice"
    },
    {
      "Statement": "Fill level with better oxygen transfer",
      "Source": "Infors HT blog",
      "Lower bound": 10,
      "Upper bound": 15,
      "Purpose or context given": "Better oxygen transfer at this level"
    },
    {
      "Statement": "Level beyond which aerobic growth is handicapped",
      "Source": "Infors HT blog",
      "Lower bound": 25,
      "Upper bound": 25,
      "Purpose or context given": "Filling beyond 25% handicaps aerobic cultures"
    },
    {
      "Statement": "Stated maximum",
      "Source": "Infors HT blog",
      "Lower bound": 0,
      "Upper bound": 20,
      "Purpose or context given": "Conclusion: fill to maximum 20% of total volume; high-density cultures are an exception"
    }
  ],
  "sources": [
    {
      "title": "Genetic Engineering and Biotechnology News: Evolution of Shake Flask Technology",
      "url": "https://www.genengnews.com/insights/evolution-of-shake-flask-technology/",
      "accessed": "2026-11-17"
    },
    {
      "title": "Infors HT: The 7 deadly sins of shake flask culture",
      "url": "https://infors-ht.com/en/blog/the-7-deadly-sins-of-shake-flask-culture",
      "accessed": "2026-11-17"
    }
  ]
}