  "name": "XRISM instruments compared: Resolve (design and gate-valve-closed) and Xtend",
  "description": "Side-by-side comparison of the two XRISM instruments, Resolve and Xtend, compiled from NASA HEASARC's XRISM overview and the Proposers' Observatory Guide. It separates Resolve's design band from the band that applies while the gate valve is closed, as reported by JAXA in August 2026.",
  "page": "https://casrai.org/guides/xrism",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-19T18:12:57Z",
  "temporalCoverage": "2023/2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Property",
      "unit": "",
      "description": ""
    },
    {
      "name": "Resolve (gate valve closed)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Resolve (nominal design)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Xtend",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Property": "Role",
      "Resolve (gate valve closed)": "High-resolution soft X-ray spectrometer",
      "Resolve (nominal design)": "High-resolution soft X-ray spectrometer",
      "Xtend": "Soft X-ray imager (four CCDs)"
    },
    {
      "Property": "Energy band (keV)",
      "Resolve (gate valve closed)": "1.7 to 12",
      "Resolve (nominal design)": "0.3 to 12",
      "Xtend": "0.4 to 13"
    },
    {
      "Property": "Field of view",
      "Resolve (gate valve closed)": "About 3 x 3 arcminutes",
      "Resolve (nominal design)": "About 3 arcminutes",
      "Xtend": "38 arcminutes on a side"
    },
    {
      "Property": "Energy resolution",
      "Resolve (gate valve closed)": "4.5 eV (high-resolution events); 4.8 eV (mid-resolution events)",
      "Resolve (nominal design)": "5 to 7 eV, non-dispersive",
      "Xtend": "Not tabulated here"
    },
    {
      "Property": "Detector layout",
      "Resolve (gate valve closed)": "6 x 6 pixel array: 35 science pixels, 1 calibration pixel, each 30 x 30 arcseconds",
      "Resolve (nominal design)": "Same array",
      "Xtend": "Four CCDs"
    },
    {
      "Property": "Effective area",
      "Resolve (gate valve closed)": "About 180 cm2 at 6 keV; about 0.5 cm2 at 1.7 keV",
      "Resolve (nominal design)": "Not tabulated here",
      "Xtend": "Not tabulated here"
    }
  ],
  "sources": [
    {
      "title": "NASA HEASARC: XRISM overview",
      "url": "https://heasarc.gsfc.nasa.gov/docs/xrism/",
      "accessed": "2026-11-19"
    },
    {
      "title": "NASA HEASARC: XRISM Proposers' Observatory Guide, Resolve",
      "url": "https://heasarc.gsfc.nasa.gov/docs/xrism/proposals/POG/Resolve.html",
      "accessed": "2026-11-19"
    },
    {
      "title": "JAXA XRISM: Mission Operations Extended Through March 2030",
      "url": "https://www.xrism.jaxa.jp/en/topics/news/1328/",
      "accessed": "2026-11-19"
    }
  ]
}