  "name": "Zero air contaminant limits named in US federal methods, an EPA audit SOP and one manufacturer line",
  "description": "Contaminant limits that define zero air in four documents: two EPA reference methods, the EPA NPAP audit SOP and Airgas product literature. Values are quoted from each document with its own analyte and unit; the limits are not interchangeable.",
  "page": "https://casrai.org/guides/zero-air-generator",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-20T00:37:28Z",
  "temporalCoverage": "2023/2026",
  "spatialCoverage": "United States",
  "columns": [
    {
      "name": "Document and context",
      "unit": "",
      "description": ""
    },
    {
      "name": "Contaminant basis",
      "unit": "",
      "description": ""
    },
    {
      "name": "Limit (less than, unless stated)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Unit",
      "unit": "",
      "description": ""
    },
    {
      "name": "Qualifier",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Document and context": "EPA Method 21 (40 CFR 60 App. A-7), zero gas",
      "Contaminant basis": "Volatile organic compounds",
      "Limit (less than, unless stated)": 10,
      "Unit": "ppmv",
      "Qualifier": "Air; limit as stated in s7.1.1"
    },
    {
      "Document and context": "EPA Method 25A (40 CFR 60 App. A-7), zero gas",
      "Contaminant basis": "Organic material (propane or carbon equivalent)",
      "Limit (less than, unless stated)": 0.1,
      "Unit": "ppmv",
      "Qualifier": "Or 0.1 percent of span value, whichever is greater"
    },
    {
      "Document and context": "Airgas chromatographic zero air generators, brass line",
      "Contaminant basis": "Total hydrocarbons as methane",
      "Limit (less than, unless stated)": 0.1,
      "Unit": "ppm",
      "Qualifier": "Manufacturer specification"
    },
    {
      "Document and context": "EPA NPAP SOP v2.0, ultrapure cylinder zero air example",
      "Contaminant basis": "Total hydrocarbons",
      "Limit (less than, unless stated)": 0.01,
      "Unit": "ppm",
      "Qualifier": "At most; example from certificate of analysis context"
    },
    {
      "Document and context": "EPA NPAP SOP v2.0, ultrapure cylinder zero air example",
      "Contaminant basis": "Carbon monoxide",
      "Limit (less than, unless stated)": 0.01,
      "Unit": "ppm",
      "Qualifier": "At most"
    },
    {
      "Document and context": "EPA NPAP SOP v2.0, ultrapure cylinder zero air example",
      "Contaminant basis": "Nitrogen oxides",
      "Limit (less than, unless stated)": 0.001,
      "Unit": "ppm",
      "Qualifier": "At most"
    },
    {
      "Document and context": "EPA NPAP SOP v2.0, ultrapure cylinder zero air example",
      "Contaminant basis": "Sulfur dioxide",
      "Limit (less than, unless stated)": 0.001,
      "Unit": "ppm",
      "Qualifier": "At most"
    }
  ],
  "sources": [
    {
      "title": "40 CFR Part 60 Appendix A-7 (Methods 21 and 25A)",
      "url": "https://www.law.cornell.edu/cfr/text/40/appendix-A-7_to_part_60",
      "accessed": "2026-11-19"
    },
    {
      "title": "Airgas Chromatographic Zero Air, Brass Line Models",
      "url": "https://www.airgas.com/airgascatalog/catalog/E117_TAG_075.pdf",
      "accessed": "2026-11-19"
    },
    {
      "title": "US EPA NPAP Standard Operating Procedure, Version 2.0, March 2023",
      "url": "https://www.epa.gov/system/files/documents/2023-08/NPAP%20SOP%20Revision%202%20March%202023_508.pdf",
      "accessed": "2026-11-19"
    }
  ]
}