  "name": "ZERODUR expansion tolerances, homogeneity limits and CTE measurement accuracy",
  "description": "One table that puts SCHOTT's published Zerodur expansion-class tolerances, blank-weight homogeneity limits, K20 mean CTE values and the TIE-37 dilatometer accuracy and repeatability figures in a single unit (10^-6 per kelvin) so they can be compared directly. Compiled from SCHOTT's product technical details and technical information note TIE-37.",
  "page": "https://casrai.org/guides/zerodur",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-22T09:00:00Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Quantity",
      "unit": "",
      "description": ""
    },
    {
      "name": "Value",
      "unit": "10^-6 per K",
      "description": "Tolerance half-width, limit, accuracy or mean CTE, as stated in the source"
    },
    {
      "name": "Kind of figure",
      "unit": "",
      "description": ""
    },
    {
      "name": "Condition or definition",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Quantity": "Expansion Class 2",
      "Value": 0.1,
      "Kind of figure": "CTE tolerance, class",
      "Condition or definition": "Mean CTE 0-50 C, 0 +/- value"
    },
    {
      "Quantity": "Expansion Class 1",
      "Value": 0.05,
      "Kind of figure": "CTE tolerance, class",
      "Condition or definition": "Mean CTE 0-50 C, 0 +/- value"
    },
    {
      "Quantity": "Expansion Class 0",
      "Value": 0.02,
      "Kind of figure": "CTE tolerance, class",
      "Condition or definition": "Mean CTE 0-50 C, 0 +/- value"
    },
    {
      "Quantity": "Expansion Class 0 SPECIAL",
      "Value": 0.01,
      "Kind of figure": "CTE tolerance, class",
      "Condition or definition": "Mean CTE 0-50 C, 0 +/- value"
    },
    {
      "Quantity": "Expansion Class 0 EXTREME",
      "Value": 0.007,
      "Kind of figure": "CTE tolerance, class",
      "Condition or definition": "Mean CTE 0-50 C, 0 +/- value"
    },
    {
      "Quantity": "TAILORED",
      "Value": 0.02,
      "Kind of figure": "CTE tolerance, variant",
      "Condition or definition": "Optimized for application temperature; 0.010 on request"
    },
    {
      "Quantity": "Homogeneity limit, blanks up to 18 tons",
      "Value": 0.03,
      "Kind of figure": "Guaranteed upper limit",
      "Condition or definition": "Highest minus lowest CTE across samples, 0-50 C"
    },
    {
      "Quantity": "Homogeneity limit, blanks up to 6 tons",
      "Value": 0.02,
      "Kind of figure": "Guaranteed upper limit",
      "Condition or definition": "Highest minus lowest CTE across samples, 0-50 C"
    },
    {
      "Quantity": "Homogeneity limit, blanks up to 0.3 tons",
      "Value": 0.01,
      "Kind of figure": "Guaranteed upper limit",
      "Condition or definition": "Highest minus lowest CTE across samples, 0-50 C"
    },
    {
      "Quantity": "Dilatometer accuracy, standard setup",
      "Value": 0.01,
      "Kind of figure": "Measurement accuracy",
      "Condition or definition": "CTE (0 C; 50 C), push-rod dilatometer"
    },
    {
      "Quantity": "Dilatometer accuracy, improved setup",
      "Value": 0.0062,
      "Kind of figure": "Measurement accuracy",
      "Condition or definition": "CTE (0 C; 50 C), interferometric readout"
    },
    {
      "Quantity": "Dilatometer repeatability (95%), standard",
      "Value": 0.005,
      "Kind of figure": "Measurement repeatability",
      "Condition or definition": "CTE (0 C; 50 C)"
    },
    {
      "Quantity": "Dilatometer repeatability (95%), improved",
      "Value": 0.0012,
      "Kind of figure": "Measurement repeatability",
      "Condition or definition": "CTE (0 C; 50 C)"
    },
    {
      "Quantity": "ZERODUR K20 mean CTE, 20-700 C",
      "Value": 2.4,
      "Kind of figure": "Mean CTE value",
      "Condition or definition": "High-temperature variant, max application temperature 850 C"
    },
    {
      "Quantity": "ZERODUR K20 mean CTE, 20-300 C",
      "Value": 2.2,
      "Kind of figure": "Mean CTE value",
      "Condition or definition": "High-temperature variant"
    },
    {
      "Quantity": "ZERODUR K20 mean CTE, 0-50 C",
      "Value": 1.6,
      "Kind of figure": "Mean CTE value",
      "Condition or definition": "High-temperature variant"
    }
  ],
  "sources": [
    {
      "title": "SCHOTT: ZERODUR technical details",
      "url": "https://www.schott.com/en-au/products/zerodur-p1000269",
      "accessed": "2026-11-18"
    },
    {
      "title": "SCHOTT TIE-37: Thermal expansion of ZERODUR",
      "url": "https://wp.optics.arizona.edu/optomech/wp-content/uploads/sites/53/2016/10/tie-37_thermal_expansion_of_zerodur_v2_us.pdf",
      "accessed": "2026-11-18"
    }
  ]
}