Skip to main content
v2026.11,610 entries · CC-BY 4.0

Ask a research-administration question

Answers are drawn from CASRAI and the rest of the CASRAI corpus, with a link to every source.

Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this

CASRAI is the reference for research administration — bookmark it for the next question.

6" Dual Sided Falling Film Evaporator -150L/hr - HYDRA

USA Lab

6" Dual Sided Falling Film Evaporator -150L/hr - HYDRA

in Falling Film Evaporators

$50,000.00 - $99,999.00

In stock

Price varies by Option.

Two mirrored 6″ falling film evaporator columns on a single mobile frame, rated 79 to 158 L/hr on ethanol (20.8 to 41.6 GPH). Solvent evaporation efficiency runs 98% at 79 L/hr down to 85% at 158 L/hr. The turnkey scope includes a C1D1 crude feed pump at 60 L/hr and a C1D1 solvent recovery pump at 150 L/hr, with a CRH-300L heater and a 5x5H multi-stage chiller as the specified utility pairing. Jacketed lines, integrated cold traps and right-angle glassware keep tubing runs short in a compact footprint.

Option

Choose Option to continue.

Buying through procurement?

Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.

Choose Option to continue.

Description

Dual 6" Falling Film Evaporator Turnkey System | Compact C1D1 Pumps
Maximize throughput without sacrificing space. The Dual 6" Falling Film Evaporator Turnkey System mirrors two full 6" evaporator columns on a single mobile frame to deliver high-performance solvent recovery in a compact footprint.
Includes both C1D1-certified pumps: a Crude Oil Pump (60 L/hr) for precise continuous feed and a Solvent Recovery Pump (150 L/hr) for fast, leak-free recovery under vacuum.
Right-angle, jacketed glassware and reduced tubing runs optimize spacing, thermal control, and serviceability—ideal for high-volume labs with limited floor space.
Dual 6" Columns Compact Single-Frame Design C1D1 Certified Pumps 24/7 Operation
Throughput: Dual 6" falling film columns double capacity while keeping a small footprint.
Certified Pumps: Includes C1D1 crude feed (60 L/hr) and recovery pump (150 L/hr).
Thermal Control: Jacketed lines, cold traps, and optimized right-angle glass for efficiency.
Owner’s Manual P&ID / Flow Diagram Specification Sheet End-Use Certification
Why this Dual 6" FFE?

Compact power — two mirrored 6" columns on a single cart save floor space.
Turnkey integration — pre-matched heaters, chillers, vacuum, and controls.
Continuous processing — thin-film evaporation for gentle, high-speed recovery.
Certified pumping — C1D1 crude feed (60 L/hr) + solvent recovery (150 L/hr).
Clean layout — right-angle, jacketed glassware and short runs reduce losses.
Technical Specifications
Model
Dual 6" Falling Film Evaporator Turnkey System
Configuration
Dual 6" evaporator columns on single mobile frame
Included Pumps
C1D1 Crude Feed Pump 60 L/hr; C1D1 Solvent Recovery Pump 150 L/hr
Solvent
Ethanol (typical); compatible with similar low-boiling solvents
Heater / Chiller Pairing
CRH-300L Heater with GD-5x5H Chiller (representative pairing)
Thermal Control
Jacketed lines, integrated cold traps, optimized right-angle glass
Operation
Continuous 24/7 capable with minimal maintenance
Use Cases
Botanical extraction, pharma refinement, chemical processing, food & flavor
Solvent

Unit Type
6" FFE
Ethanol
Throughput (LPH)
79
93
116
158
Heater
CRH-300L
Throughput (GPH)
20.8
24.5
30.5
41.6
Chiller
GD-5x5H
Solvent Evaporation Efficiency
98%
95%
90%
85%
Featured Equipment
Crude Oil Pump – 60L/HR – C1D1 Certified
Transfers viscous crude oil seamlessly into the system.
Solvent Recovery Pump – 75L-100L/HR – C1D1 Certified
Recovers evaporated solvents under vacuum with continuous operation.
UL Listed 21CFM UVP-21 Corrosion Resistant 2-Stage Vacuum Pump
Corrosion-resistant design supports stable evaporation.
G&D Multi Stage Chiller 5x5H
Matched process chiller for condenser loads.
CRH Closed Loop Heaters – 300°C – 6kw, 9kw, 18kw,27kw & 36kw
Turnkey pairing
Dual FFE-6" Options — Items
Standalone
Pump Integration
Turnkey
Dual 6" falling Film Evaporator
X
X
X
Crude Pump

X
X
Solvent Pump

X
X
Vacuum Pump

X
X
G&D 5x5H Chiller
X
CRH-300L Heater
X
FAQ

How does a falling film evaporator increase recovery speed?

It spreads solvent into a thin film across heated tubes, maximizing surface area for rapid evaporation and continuous collection.
What throughput can I expect with ethanol?

Typical ethanol rates are 79/93/116/158 LPH (about 20.8/24.5/30.5/41.6 GPH ) depending on utilities and configuration.
Are pumps included and compliant?

Yes. The turnkey package includes a C1D1 crude feed pump (60 L/hr) and a C1D1 solvent recovery pump (150 L/hr) .
Is the system suitable for continuous 24/7 operation?

Yes. With proper utilities and maintenance, the dual 6" FFE is designed for continuous duty and minimal downtime.

Frequently asked questions

What ethanol throughput does the dual 6" system deliver?+

79, 93, 116 or 158 L/hr (approximately 20.8, 24.5, 30.5 and 41.6 GPH), at 98%, 95%, 90% and 85% solvent evaporation efficiency respectively. The higher the rate, the lower the single-pass efficiency.

Which pumps are included in the turnkey configuration?+

A C1D1 crude feed pump rated 60 L/hr and a C1D1 solvent recovery pump rated 150 L/hr. Pump Integration adds crude, solvent and vacuum pumps to the Standalone frame; Turnkey adds the G&D 5x5H chiller and CRH-300L heater on top of that.

What heater and chiller does it need?+

The specified pairing is a CRH-300L closed-loop heater with a G&D 5x5H multi-stage chiller. If you are integrating with existing utilities, size them against that pairing rather than against a single-column unit.

Why two columns rather than one larger one?+

Two mirrored 6" columns on one frame roughly double column capacity while keeping the machine on a single mobile cart, which matters where floor space rather than utility capacity is the constraint.

Which solvent is it specified for?+

Ethanol is the specified solvent and all published throughput figures are ethanol figures. Verify compatibility of the wetted materials and the vacuum path before running any other solvent.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →