Skip to main content
v2026.11,610 entries · CC-BY 4.0

Ask a research-administration question

Answers are drawn from CASRAI and the rest of the CASRAI corpus, with a link to every source.

Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this

CASRAI is the reference for research administration — bookmark it for the next question.

Beaker & Wrench Dual 6" Wiped Film Evaporator

SKU BW-6WFE-D

Beaker & Wrench

Beaker & Wrench Dual 6" Wiped Film Evaporator

in Wiped Film Distillation

$390,000.00

In stock

Dual 6-inch wiped film evaporation system with a 40 L feed tank, 36 CFM rotary vane vacuum pump, −90 °C immersion probe and 8-channel UL-listed PID control.

Buying through procurement?

Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.

Ordering several items? Add them to your cart, then create one quote for the whole cart.

Description

Beaker & Wrench continues to be an industry leader, bringing together scientific expertise and real-world industry experience.
Take the guess-work out of large scale cannabis oil distillation with our Wiped Film Evaporator Turn-Key System. It arrives fully functional, meaning you can take advantage of the latest technology immediately and without additional installation or training costs.
Other control processes can be subjective and vulnerable to user error, but our automated, Dual 6″ Wiped-Film Evaporation Turn-Key System will help maximize your product outcomes with greater productivity and maximum purity.

Key Features and Benefits

Plug-and-Play Installation:

The Wiped-Film Evaporation Turn-Key System is ready to use right out of the box. This eliminates the need for complex setup procedures and extensive training, saving you time and money.

Precision Temperature Control:

Equipped with an 8-channel UL-Listed PID Temperature Controller, the system ensures precise and consistent temperature management, crucial for achieving optimal distillation results.

Efficient Feed System:

A 40L feed tank supports continuous operation, reducing downtime and increasing throughput.

High-Performance Vacuum Pump:

The 36 CFM Rotary Vane Vacuum Pump maintains an optimal vacuum environment, which is essential for efficient distillation and high product purity.

Advanced Cooling Technology:

The -90°C immersion probe negates the need for dry ice, simplifying operations and reducing operational costs.

Automated Flow Control:

Inlet and outlet gear pumps ensure a continuous and controlled flow of material, enhancing process stability and product consistency.

Single Power Source:

The entire system operates on a single NEMA 14-50 Single-Phase 240V plug, simplifying electrical requirements and setup.

Certified Quality:

The CE certification confirms the system meets stringent European safety and performance standards, giving you peace of mind regarding its reliability and quality.

With Beaker & Wrench’s Wiped-Film Evaporation Turn-Key System, you can elevate your cannabis oil distillation process, achieving unparalleled productivity, purity, and consistency.

*Beaker & Wrench Spec Sheet*

Specification

Details

Dimensions (HxWxD)

75” W x 30” D x 86” H (can be reduced to 80” H to fit through doors)

Temperature Control

8-channel UL-Listed PID Temperature Controller

Feed Tank Capacity

40L

Vacuum Pump

36 CFM Rotary Vane Vacuum Pump

Cooling

-90°C Immersion Probe (no dry ice needed)

Flow Control

Inlet and Outlet Gear Pumps (continuous flow)

Power Requirements

One NEMA 14-50 Single-Phase 240V Plug

Evaporative Area

0.25m² Evaporative Area (Evaporator Body)

Certification

CE Certified

Frequently asked questions

What temperature control does the system use?+

An 8-channel UL-listed PID temperature controller.

Does this system require dry ice?+

No. A −90 °C immersion probe is used in place of dry ice for the cold trap duty.

What vacuum pump is supplied?+

A 36 CFM rotary vane vacuum pump.

What power connection is required?+

A single NEMA 14-50 single-phase 240 V plug.

Will it fit through a standard doorway?+

The spec sheet gives 75 in W × 30 in D × 86 in H, and notes the height can be reduced to 80 in to fit through doors.

What certification does it carry?+

The product data states CE certification. No other listing mark is recorded in the supplied data, so confirm anything further with the manufacturer before citing it in a compliance submission.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →