Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this

CASRAI is the reference for research administration — bookmark it for the next question.

Edwards E2M1.5 Two-Stage Rotary Vane Vacuum Pump - 1 cfm

Edwards

Edwards E2M1.5 Two-Stage Rotary Vane Vacuum Pump - 1 cfm

in Vacuum Pumps

$3,399.00

In stock

Price varies by Option.

Edwards E2M1.5 two-stage oil-sealed rotary vane pump, up to 1.18 CFM at 60 Hz with an ultimate pressure of 2.25 mTorr and a DN 10 ISO-KF inlet.

Option

Choose Option to continue.

Buying through procurement?

Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.

Choose Option to continue.

Description

Compact, reliable, and quiet, this two-stage oil-sealed rotary vane pump delivers consistent medium/rough vacuum performance for lab and industrial workflows. With up to 1.18 CFM pumping speed (60 Hz) and an ultimate pressure down to 2.25 mTorr , it’s ideal for evacuation, degassing, drying, filtration, and GC/MS foreline duties.
Engineered with DN 10 ISO-KF inlet, 11 mm nozzle / 3/4" BSPP female outlet, IE2 efficiency motor, and IP44 protection. Air-cooled operation keeps sound to just 55 dB(A) while the compact footprint (0.323 m L × 0.142 m W × 0.178 m H) fits tight benches.
Runs on 100–120 V, 50/60 Hz, single-phase with 160 W rated power. Uses Edwards 45 vacuum oil. Note: regional power cable not included; some variants require hard-wiring.

Always operate within specified temperature and altitude limits for optimal life and performance.
1.18 CFM @ 60 Hz Ultimate 2.25 mTorr DN 10 ISO-KF Inlet 55 dB(A) Quiet
Quiet Operation: ≤ 55 dB(A) with forced-air cooling for a better work environment.
Clean, Stable Vacuum: Two-stage design achieves 2.25 mTorr ultimate for consistent results.
Compact & Efficient: IE2 motor, IP44 protection, and 160 W rated power.
Instruction Manual Maintenance Kit Manual
Why this rotary vane pump?

Trusted performance — 1.18 CFM @ 60 Hz pumping speed; 0.942 CFM @ 50 Hz .
Deep ultimate vacuum — down to 2.25 mTorr (18.75 mTorr with gas ballast).
Easy integration — DN 10 ISO-KF inlet; 11 mm nozzle / 3/4" BSPP outlet.
Lab-ready power — 100–120 V, 1-Ph, 50/60 Hz ; 160 W rated.
Quiet & compact — just 55 dB(A) with a small footprint to save bench space.
Technical Specifications
Model
Two-Stage Oil Rotary Vane Vacuum Pump
Inlet / Outlet
DN 10 ISO-KF inlet / 11 mm nozzle, 3/4" BSPP (G 3/4") female outlet
Pumping Speed (60 Hz)
1.18 CFM (Air/N 2 )
Pumping Speed (50 Hz)
0.942 CFM (Air/N 2 )
Ultimate Pressure
2.25 mTorr (3.0×10 -3 mbar)
Ultimate w/ Gas Ballast
18.75 mTorr
Power / Frequency
160 W total rated @ 50/60 Hz; 1-Ph 100–120 V
Noise / Cooling
55 dB(A) / Forced air-cooling (fan)
Dimensions (L × W × H)
0.323 m × 0.142 m × 0.178 m
Weight
10.00 kg
Ingress / Motor Class
IP44 / IE2
Electrical Connector
IEC EN60320 C14 (mates with C13 mains cable)
Certifications
UL 61010-1 (3rd Ed.); CSA C22.2 No.61010-1-12
Operating Limits
Ambient 12–40 °C (285.15–313.15 K); Storage −30–70 °C (243.15–343.15 K); Altitude ≤ 2000 m
FAQ

What vacuum range does this pump cover?

It is suitable for medium to rough vacuum applications (approx. 1000 mbar to 1×10 −3 mbar), achieving an ultimate pressure of 2.25 mTorr in clean conditions.
Which oil should I use and how much?

Use Edwards 45 oil. Typical oil capacity is 0.20–0.28 L (2.0×10 −4 to 2.8×10 −4 m 3 ) depending on service level.
Does it include a power cable?

The required mains cable is not included . Some variants require hard-wiring—verify local electrical requirements before installation.
What are the ambient operating limits?

Operate between 12–40 °C ambient (285.15–313.15 K) up to 2000 m altitude. Store between −30–70 °C (243.15–343.15 K).

Frequently asked questions

What is the pumping speed and ultimate pressure?+

Up to 1.18 CFM at 60 Hz, with an ultimate pressure down to 2.25 mTorr.

What are the connections?+

DN 10 ISO-KF inlet, with an 11 mm nozzle / 3/4 in BSPP female outlet.

What voltage options are available?+

100–120 V or 200–230 V.

What is it typically used for?+

Edwards list evacuation, degassing, drying, filtration and GC/MS foreline duty.

What motor is fitted?+

An IE2 efficiency motor.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →