Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this

CASRAI is the reference for research administration — bookmark it for the next question.

UltraChill 29.6 Cu Ft -86°C Upright Ultra-Low Freezer - Touch Screen - UL Listed -80°C ULT

SKU UCF-29.6-86-UL

USA Lab

UltraChill 29.6 Cu Ft -86°C Upright Ultra-Low Freezer - Touch Screen - UL Listed -80°C ULT

in Freezers

$15,000.00

In stock

Upright −86 °C ULT freezer holding 838 L (29.59 cu ft), the largest UltraChill upright. −40 to −86 °C cascade, 600 two-inch boxes across 24 racks.

Buying through procurement?

Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.

Ordering several items? Add them to your cart, then create one quote for the whole cart.

Description

Introducing our UltraChill 29.6 Cu Ft (838 L) –86°C Upright Ultra-Low Freezer, engineered to safeguard high-value biologicals, enzymes, vaccines, and temperature-sensitive pharmaceuticals. With best-in-class temperature uniformity and robust construction, UltraChill delivers reliable long-term sample integrity for research, clinical, and biobank environments.
The UltraChill Series offers a wide –40°C to –86°C set-point range with microprocessor precision and a 7″ LCD touchscreen for intuitive control, real-time monitoring, and streamlined compliance.
Advanced insulation (PURF + VIP) and an efficient cascade system using eco-forward HC (R290/R170) refrigerants reduce energy consumption while maintaining rapid pull-down and tight stability.
–86°C ULT 29.6 cu ft (838 L) 7″ Touchscreen Control Cascade System
HC Refrigerant (R290/R170) UL Listed Energy Efficient Uniformity Optimized
Deep ULT performance: –40°C to –86°C with tight stability and fast recovery after door openings.
Superior uniformity: Direct-cooling air management minimizes gradients for consistent sample conditions.
Safety first: UL listed cabinet with multi-event alarms (temp, power, door, sensor, voltage, battery).
User Manual
Why this –86°C Ultra-Low Freezer?

Reliable ultra-low storage — –40°C to –86°C range protects sensitive samples long-term.
Touchscreen control — microprocessor accuracy with 7″ LCD for set-points, logs, and status.
Eco-forward efficiency — cascade system with HC (R290/R170) and VIP insulation reduces energy use.
Comprehensive alarms — high/low temp, power failure (72h backup), door ajar, sensor/voltage faults.
High storage density — up to 24 (5×5) rack positions; ~600 two-inch boxes; ~60,000 × 2 mL vials.
Technical Specifications
Basic
Refrigeration System
Alarms
Cooling type
Direct Cooling
Refrigerant
HC (R290 & R170)
High/low temperature
Y
Defrost
Manual
Temp. controller
Microprocessor
Power failure
Y
Temperature range
-40°C ~ -86°C
System
Cascade system
Abnormal voltage
Y
Ambient temperature
10~32°C
Sensor
PTC
Sensor error
Y
Display
7" LCD touch screen
Compressor brand/QTY
SECOP / 2
Door ajar
Y
Access port QTY/Dia.
1 / 25 mm
Capacity (L/cu.ft)
838 / 29.59
Filter screen check
Y
USB Access
Y
Insulation
PURF + VIP
Thermostat failure
Y
Remote alarm Access
RS232/485
Inner door material/QTY
Foamed SUS304 / 2
Low battery
Y
Outside material
Color sprayed steel
Racks
24 (5×5)
Condenser clean
Y
Inside material
SUS304
Boxes (2")
600
High ambient temperature
Y
Castor
Universal
Samples (2 mL)
60,000
Door ajar
Y
Power failure backup (alarm)
72 h
Electrical Data
Dimensions
Accessories
Voltage frequency (V/Hz)
110V / 120V 60Hz
Package size (W×D×H) (in)
50" × 43" × 86"
Chart recorder
Optional
Power (W)
720W
Exterior size (W×D×H) (in)
46" × 45" × 78.5"
Data logger
Y
Current (A)
8.64A
Interior size (W×D×H) (in)
35" × 28.2" × 51.6"
CO 2 back up system
Optional
Power consumption
16.47 kWh/24h
Net Weight (lbs)
730 lbs
LN 2 back up system
Optional
Noise (dB)
53
Shipping Weight (lbs)
900 lbs
Gloves
Optional
Biobanking Pharmaceutical Clinical Lab Academic & Research
FAQ

What applications fit the UltraChill –86°C Upright?

Ideal for long-term storage of vaccines, enzymes, cell lines, tissues, reagents, and reference standards in research, clinical, and biobank settings.
How does UltraChill maintain temperature uniformity?

Direct-cooling with optimized airflow and high-performance insulation (PURF + VIP) minimizes gradients and speeds recovery after door openings.
What alarms and protections are included?

High/low temp, door ajar, power failure with 72-hour backup, sensor error, abnormal voltage, condenser clean, thermostat failure, and low battery notifications.
Is the UltraChill 29.6 Cu Ft –86°C Freezer energy efficient?

Yes. The cascade system with HC refrigerants and VIP insulation reduces power draw while maintaining stability and rapid pull-down.
Installation & delivery tips

Measure access paths: confirm doorway and corridor widths vs. crate size. Provide dedicated circuit: 110/120 V, 60 Hz. Allow clearance for ventilation and service.

Specifications
Power:
110V/120V 60Hz
Noise:
53 dba
Temp Range:
-40℃~-86℃
Capacity(L/cu.ft):
838/29.59
Weight:
730 lbs
Internal Dimensions (WxDxH):
35" x 28.2" x 51.6"
External Dimensions (WxDxH):
46" x 45" x 78.5"
Certification:
CE, UL

Frequently asked questions

How much will it hold?+

24 racks in a 5×5 arrangement taking 600 two-inch boxes, approximately 60,000 vials at 2 ml. Interior dimensions are 35 × 28.2 × 51.6 in. This is the highest-density option in the series — worth weighing against the risk concentration of putting 60,000 samples behind one compressor pair.

What refrigeration system does it use?+

A cascade system with two SECOP compressors on HC refrigerants (R290 and R170), with direct cooling, manual defrost, PTC sensing and PURF plus VIP insulation. Hydrocarbon refrigerants have a low global warming potential but are flammable, so review the installation location against your institution's requirements for flammable-refrigerant equipment.

What power supply and consumption should I budget for?+

110 V / 120 V 60 Hz, 720 W, 8.64 A, with a stated consumption of 16.47 kWh per 24 hours and 53 dB of noise. Permissible ambient is 10 to 32 °C. Over a ten-year service life the energy cost at this consumption is a material line in a total-cost comparison against a smaller cabinet.

What monitoring is included?+

A microprocessor controller with a 7 in LCD touchscreen, a data logger as standard, USB access and remote alarm access over RS232/485. Alarms cover high and low temperature, power failure, abnormal voltage, sensor error, door ajar, filter screen check, thermostat failure, low battery, condenser clean and high ambient temperature, with 72 hours of battery backup for the alarm system. CO₂ and LN₂ backup systems and a chart recorder are listed as options.

What space and access do I need for delivery?+

Exterior 46 × 45 × 78.5 in, net weight 730 lb, shipping weight 900 lb, packaged 50 × 43 × 86 in. Check the packaged dimensions and the 900 lb shipping weight against your doorways, corridor turns, lift capacity and floor loading before delivery is scheduled. Universal castors are fitted for final positioning.

What certification does the product data record?+

The product data states the cabinet is UL listed. If your installation or accreditation record requires documented evidence, ask for the listing file number and the certificate rather than relying on the listing text alone.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →