Skip to main content
v2026.11,610 entries · CC-BY 4.0

Ask a research-administration question

Answers are drawn from CASRAI and the rest of the CASRAI corpus, with a link to every source.

Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this

CASRAI is the reference for research administration — bookmark it for the next question.

H1-2 2L Full Bore Short Path Distillation Kit

USA Lab

H1-2 2L Full Bore Short Path Distillation Kit

in Short Path Distillation

$1,699.00 - $4,399.00

In stock

Price varies by Choose a Mantle.

2 L full-bore short path distillation kit in borosilicate glass with a 34/45 head, 34/45 vacuum take-off adapter and two 24/40 cold traps.

Choose a Mantle

Choose Choose a Mantle to continue.

Buying through procurement?

Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.

Choose Choose a Mantle to continue.

Description

Our 2L Short Path Distillation Kit is made with high quality borosilicate Glass and a wide 34/45 head to allow for excellent distillation, high production, and consistent results.
This lab distillation kit comes with a large 34/45 distillation head, a 34/45 vacuum take-off adapter to allow for easy switching of receiving flasks, two 24/40 cold traps for large amounts of condensing, and full-bore attachments to allow for high pulling vacuum.
Choose the best quality at the best value with this lattice supported high quality glass distillation apparatus kit.

C-SD2L-H1TK Specifications

Flask Size

2L (2000mL)

Flask Joint Sizes

34/45 Main | 24/40 Side

Distillation Head Joint Sizes

34/45 Bottom | 24/40 Top | 34/45 Side

Isolation Adapter Joint Sizes

34/45 Inlet | 24/40 Outlet | 24/40 Bottom Discharge

Left Cold Trap Joint Sizes

24/40

Right Cold Trap Joint Sizes

24/40

Optimal Capacity

400-1000mL

Batch Time

4-8 Hours

Main Body Flow Rate

100-400 grams/hour

Footprint

80″ x 24″ x 40″ Includes Pump & Chiller

Heating Mantle (option)

2LMANTLE: 110-120V 60Hz 15A 450W 6-15P Plug Installed

100D-TEM110M: 110-120V 15A 5-15P Plug Installed x2

USA-HM-2L: 110-120V 450W

C-SD2L-H1TK Packing List

Model

Quantity

2L Mantle

1

2L 2-Neck RBF – 24/40, 34/45 Center

1

2L 34/45 H1-2 Distillation Head

1

250mL 1-Neck RBF – 24/40

2

500mL 1-Neck RBF – 24/40

1

34/45 Isolation Adapter

1

24/40 Male Cold Trap

1

24/40 Female Cold Trap

1

Cold Trap Lid

2

S35/20 250ml RBF

2

2L Flask Thermowell 24/40

1

2L Head Thermowell 24/40

1

GL-18 Connection

4

34/45 Keck Clamp

2

24/40 Keck Clamp

4

Red Large Clamp Retort 3 Prong

4

Chain Clamp for Lab Stand

2

Stainless Steel S35 Pinch Clamp

2

4″ Diameter Extension Support Ring

2

Boss Head Clamp

18

Small Cork Stand

2

Medium Cork Stand

1

6″ x 8″ Lab Stand

4

4″ x 4″ Lab Jack

1

48″ SS Rod

3

KF25 to 24/40 PTFE Adapter

1

KF25 Wing Nut Clamp

2

KF25 Vacuum Pump Centering Ring

2

Mantle Manual

1

HM-2L HEATING MANTLE INFORMATION

Our HM heating and stirring mantles are a top of the line product compared to others that are currently on the market while maintaining an affordable price. Each mantle comes standard with a digital display for ease of use and accurate control. Rotation speeds are easily done by a knob rather than a digital display for ease of use and superior control. Our magnet motor is one of the most powerful on the market, yielding better agitation and more control.

Our HM mantles come equipped with high quality parts to serve you better and to make your mantle last longer. Each unit comes with a extremely accurate K-Type probe, as well as an insulating heating top for exceptional heat retention inside your flask.

Manual

SPECIFICATIONS

Capacity

2L

5L

12L

22L

Dimension

Φ270x220mm

Φ330x220mm

Φ400x300mm

Φ450x330mm

Φ10.62×8.66inch

Φ12.99×8.66inch

Φ15.74X11.81inch

Φ17.71×12.99

Jacket Heater

110-120V, 350W

110-120V, 600W

220-240V, 1000W

Frequently asked questions

What heating mantle options are there?+

Three: the USA Lab mantle with insulating top (300 °C, 1200 RPM, 220–240 V 60 Hz 15 A 450 W); the USA Lab mantle with heating top (300 °C, 3000 RPM, 110–120 V 60 Hz 15 A 800 W); or the Glas-Col with heating top (400 °C, 110–120 V 60 Hz 15 A 700 W, 100D-TEM110M).

What is in the glassware kit?+

A 34/45 distillation head, a 34/45 vacuum take-off adapter, two 24/40 cold traps, full-bore attachments and a lattice support.

Do the mantles run on the same supply?+

No. The insulating-top mantle is 220–240 V while both heating-top options are 110–120 V.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →