Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this
CASRAI is the reference for research administration — bookmark it for the next question.

Huber
Huber CC-902 with Pilot ONE
$36,300.00 - $36,800.00
In stockPrice varies by Certification.
Two-stage refrigerated bath circulator reaching −90 °C, working −90 to 200 °C at ±0.02 °C under Pilot ONE. R452A/R508B cascade, air cooled.
Choose Certification to continue.
Buying through procurement?
Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.
Choose Certification to continue.
Description
The Refrigeration Bath Circulators are created to control the temperature of externally connected. Applications are: photometers, refractometers, viscometers, double-jacketed reaction vessels and autoclaves. the units can be used, for determining the freezing point, for deep temperature calibration, for petroleum tests, for temperature control of measuring devices and experimental setups as well as for materials testing and quality control.
Download Data Sheet
Click Here
Please observe the notes on installation and/or the space requirements of our products
General information & Temperature Controller
Temperature range
-90…200 °C
Temperature stability ±0.02 °C
±0.02 °C
Controller Pilot ONE (E-grade “Basic”)
Pilot ONE (E-grade “Basic”)
Safety class
III / FL
Protection class
IP20
Dimensions (W x D x H)
550 x 600 x 911 mm | 21.65 x 23.62 x 35.87 inches
Weight
139 kg | 306.5 pounds
Heating / Cooling Capacity
Heating capacity
1,2 kW
Cooling capacity
100 20 0 -20 -40 -60 -80 °C1,2 1,2 1,2 1,1 0,9 0,6 0,2 kW
Cooling machine
air-cooled
Refrigerant 1. stage
R452A (A1, H280) (0,78 kg)
Refrigerant 2. stage
R508B (A1, H280) (0,46 kg)
Circulation Pump
Pressure pump max.
25 lpm ; 0.7 bar | 6.6 gpm ; 10.15 psi
Suction pump max.
18.5 lpm ; 0.4 bar | 4.89 gpm ; 5.8 psi
Pump Connection
M16x1 AG male
Permissible viscosity
50 mm²/s
Connections
Pt100 connection
Pt100
Digital interface
RS232, Ethernet, USB Device, USB Host
Operating Data
Permissible ambient temp.
5…40 °C
Bath opening W x D / BD
120 x 110 / 150 mm | 4.72 x 4.33 / 5.91 inches
Bath volume
5 Liters | 1.32 gal
Power supply
208V 2~ 60Hz
Current max.
18 A
Fusing
2×20 A
Frequently asked questions
How does the two-stage refrigeration circuit work here?+
The unit uses a cascade: a first stage charged with 0.78 kg of R452A and a second stage charged with 0.46 kg of R508B. Both are classified A1 (non-flammable) under ASHRAE. The cascade is what allows a −90 °C bath temperature from an air-cooled machine.
What cooling capacity is available across the range?+
The data sheet gives 1.2 kW at 100 °C, 20 °C and 0 °C, 1.1 kW at −20 °C, 0.9 kW at −40 °C, 0.6 kW at −60 °C and 0.2 kW at −80 °C. Heating capacity is 1.2 kW.
How large is the bath?+
Bath volume is 5 litres, with an opening of 120 × 110 mm and a usable depth of 150 mm (4.72 × 4.33 in, 5.91 in deep). It is a small bath for the machine size — most of the footprint is the cascade refrigeration plant.
What are the electrical and space requirements?+
208 V 2~ 60 Hz, drawing a maximum of 18 A with 2 × 20 A fusing. The unit measures 550 × 600 × 911 mm (21.65 × 23.62 × 35.87 in) and weighs 139 kg (306.5 lb), so a bench check is worth doing before delivery.
What pump performance does it provide?+
25 lpm at 0.7 bar in pressure mode and 18.5 lpm at 0.4 bar in suction mode, through M16x1 male connections, with a permissible fluid viscosity of 50 mm²/s. Note that thermofluid selection matters at −90 °C: viscosity at the low end of the range governs achievable flow.
What controller does it use?+
Pilot ONE at E-grade "Basic" with a 5.7 in colour touchscreen, Pt100 external probe connection, and RS232, Ethernet, USB Device and USB Host interfaces for remote control or data capture.