Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this

CASRAI is the reference for research administration — bookmark it for the next question.

Huber KISS K6 4.5L -25 to 200°C Heater Chiller 110V 15A

SKU KISS-K6

Huber

Huber KISS K6 4.5L -25 to 200°C Heater Chiller 110V 15A

in Chiller/Heater Combos

$7,760.00

In stock

Huber KISS K6 heating circulator, −25 to 200 °C held to ±0.05 °C, on a 4.5 L bath with a natural refrigerant and an OLED KISS controller. 110 V, 15 A.

Buying through procurement?

Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.

Ordering several items? Add them to your cart, then create one quote for the whole cart.

Description

Cooling bath thermostats with insulated cooling baths are an economic solution for thermoregulation of objects directly in the thermostat bath. The units are therefore suitable for a number of typical heating and cooling tasks such as sample temperature control, materials testing, quality control, analyses, etc. Cooling circulator operates with natural refrigerants and are therefore offer an environmentally friendly solution to temperature control. In addition, cooling circulators are fitted with automatic refrigeration capacity adjustment, reducing energy consumption and waste heat down to the absolute essential. With low level protection and adjustable over heating protection the units fulfil the requirements of Safety Class III/FL according to DIN 12876. The thermostats can also be used for externally attached applications using the pump connections at the rear.

The new KISS controller combines state-of-the-art technology with simple operation and stylish design. KISS models are suitable for routine tasks in research and industry and are convincing as practice oriented basic equipment. Option: Pt100 sensor connection #10519 to display (not control) e.g. of the process temperature (only available factory fitted, additional charge).

KISS temperature controllerBright, large OLED displaySimple operation with menu navigationSimultaneous display of setpoint, Tmin, Tmax and actual temperatureStatus displays for pump, cooling, and heatingOvertemperature and low-level protectionSafety class III/FL (DIN 12876)USB and RS232 interfacesAutoStart function for power failure3 color versions available: grey (standard), blue, red Natural refrigerant

Huber KISS K6 Specifications

General Information & Temperature Controller

Temperature Range

-25…200°C

Temperature Stability

±0.05 °C

Temperature Display

OLED Display

Alarm Message

Optical, Acoustical

Controller

KISS

Safety Class

III / FL

Protection Class

IP20

Dimensions (WxDxH)

8.27″ x 15.75″ x 21.5″

Weight

25 kg | 55.12lbs

Heating / Cooling Capacity

Heating Capacity

1,5 kW

Cooling Capacity

20

0

-10

-20

°C

0,26

0,21

0,15

0,05

kW

Cooling Machine

Air-Cooled

Refrigerant (ASHRAE, GHS)

R290 (A3, H220) (0,047 kg)

Circulation Pump

Pressure Pump Max.

14lpm; 0.25 bar | 3.7gpm; 3.62 psi

Suction Pump Max.

10.5lpm; 0.17 bar | 2.77gpm; 2.47 psi

Pump Connection

M16x1 AG Male

Connections

Digital Interface

USB, RS232

Operating Data

Permissible Ambient Temp.

5…40°C

Bath Opening WxD/BD

5.51″ x 4.72″ / 5.91″

Bath Volume

4.5 Liters | 1.19 gal

Power Supply

110-120V 1~ 50/60Hz

Current Max.

15 + 3,2 A

Frequently asked questions

What is the temperature range and stability?+

−25 to 200 °C, with a stated temperature stability of ±0.05 °C.

What does the display show?+

A large OLED display showing setpoint, Tmin, Tmax and actual temperature simultaneously, plus status displays for pump, cooling and heating.

What safety features are fitted?+

Overtemperature and low-level protection, and safety class III/FL to DIN 12876.

What happens after a power failure?+

An AutoStart function is provided for power failure recovery.

What interfaces does it have?+

USB and RS232.

What are the dimensions?+

8.27 × 15.75 × 21.5 inches (W × D × H). Three colour versions are listed: grey (standard), blue and red.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →