Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this

CASRAI is the reference for research administration — bookmark it for the next question.

NSF Certified Class II Type A2 Biosafety Cabinet With Detachable Stand - Various Sizes

USA Lab

NSF Certified Class II Type A2 Biosafety Cabinet With Detachable Stand - Various Sizes

in Fume Hoods

$6,500.00 - $8,000.00

In stock

Price varies by Size.

NSF certified Class II Type A2 biosafety cabinet in 3, 4 or 6 ft widths, with all exhaust air HEPA filtered before release and a detachable stand.

Size

Choose Size to continue.

Buying through procurement?

Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.

Choose Size to continue.

Description

The Class II Type A2 Biosafety Cabinet (BSC) provides personnel, product, and environmental protection for handling infectious or potentially infectious materials. All exhaust air is HEPA-filtered prior to release, maintaining a safe workspace that meets NSF/ANSI 49 performance criteria.
Unlike clean benches that blow unfiltered air toward the user, and unlike chemical fume hoods that lack product protection, this NSF Certified Class II Type A2 Biosafety Cabinet combines inward airflow with HEPA-filtered laminar downflow for comprehensive protection. A motorized, laminated safety glass window, dual HEPA filters with life indicators, microprocessor control, and stainless-steel work zone simplify safe operation and cleaning.
Typical workflow: close sash → run UV for 30 minutes to disinfect → set sash to the 10" safety height and allow 10 minutes of stabilization → perform work → close sash and run UV for 30 minutes for post-use decontamination.
Ductwork not included, you will need to install your own ducting.

NSF/ANSI 49 Certified Class II Type A2 Dual HEPA (99.995% @ 0.3μm) LCD Controls & Alarms
Sterile, Contained Airflow: Inward inflow with 60% HEPA-filtered downflow and 40% HEPA-filtered exhaust helps keep users, products, and the lab environment safe.
Built-In Safety: Motorized sash with 10" tested opening, filter life & airflow alarms, UV germicidal lamp (253.7 nm), and ≤67 dB noise (NSF 49).
Lab-Ready Utility: 304 SS work surface, water & gas taps, waterproof sockets (≤500 W total), bright ≥1000 Lux LED lighting, and optional height-adjustable base.
User Manual
Why this Class II Type A2 BSC?

NSF Certified performance — the NSF Certified Class II Type A2 Biosafety Cabinet meets NSF/ANSI 49 to protect people, product, and environment.
Dual HEPA filtration — 99.995% @ 0.3μm with filter life indicator for reliable containment.
Operator-friendly controls — LCD display, airflow alarms, motorized sash, high-efficiency ECM blower.
Bright, ergonomic workspace — ≥1000 Lux LED lighting, stainless chamber, quiet ≤67 dB operation.
Good practice guidance — avoid flammables/volatile toxics; use approved disinfectants (bleach, iodophors, phenolics, quats) and follow pre/post UV protocols.
Technical Specifications
Specification
USA-BSC-3FT
USA-BSC-4FT
USA-BSC-6FT
External Size (W×D×H)
1087×775×2265 mm | 42.8"×30.5"×89.2"
1383×775×2295 mm | 54.5"×30.5"×90.4"
1873×775×2295 mm | 73.8"×30.5"×90.4"
Internal Size (W×D×H)
910×600×660 mm | 36"×23.6"×26"
1210×600×660 mm | 48"×23.6"×26"
1700×600×660 mm | 67"×23.6"×26"
Work Surface Height
750 mm
Max Opening
520 mm (20.5")
550 mm (22")
550 mm (22")
Tested Opening
Safety sash height 254 mm (10")
Inflow
445 m³/h (259 cfm)
587 m³/h (346 cfm)
824 m³/h (485 cfm)
Downflow
60%: 649 m³/h (382 cfm)
60%: 863 m³/h (507 cfm)
60%: 1212 m³/h (713 cfm)
Exhaust
40%: 441 m³/h (259 cfm)
40%: 587 m³/h (346 cfm)
40%: 824 m³/h (485 cfm)
Front Window
Motorized, two-layer laminated toughened glass ≥5 mm, Anti-UV
HEPA Filters
Two; 99.995% efficiency @ 0.3 μm; filter life indicator
Filter Guard Type
Aluminum alloy frame
Aluminum alloy frame
Aluminum alloy frame
Noise (NSF 49)
≤67 dB
≤67 dB
≤67 dB
Illumination
≥1000 Lux
≥1000 Lux
≥1000 Lux
Display
LCD
LCD
LCD
Waterproof Sockets
2 (total ≤500 W)
2 (total ≤500 W)
2 (total ≤500 W)
Utilities
Water tap ×1, Gas tap ×1
Water tap ×1, Gas tap ×1
Water tap ×1, Gas tap ×1
Ground Resistance
≤0.10 Ω
≤0.10 Ω
≤0.10 Ω
Power Supply
110V±10% 60 Hz; Full load: 9 A
Power Consumption
400 W
500 W
700 W
Alarms
Abnormal airflow velocity; filter replacement; front window at unsafe height
Motor/Blower
ECM motor; 110 V & 220 V acceptable; speed adjustable; high efficiency/low power
Materials
Work area: 304 stainless steel; frame/decorative plate: cold-rolled steel with anti-bacterial powder coating
UV Lamp
20 W
30 W
40 W
UV Type
Germicidal UV, 253.7 nm emission
Illuminating Lamp
10 W ×2 | LED
18 W ×2 | LED
22 W ×2 | LED
Standard Accessories
Illuminating lamp, two UV lamps, base stand, SS water & gas taps, drain valve, waterproof sockets, stainless I.V. bar with 10 hooks
Optional Accessories
Armrest, airflow tester, formalin fumigation sterilizer, infrared sterilizer, electric height-adjustable base stand, remote control
Package Size (W×D×H)
1240×1060×1840 mm | 49"×42"×72.5"
1540×1080×1900 mm | 60.6"×42.5"×75"
2020×1080×1900 mm | 79.5"×42.5"×75"
Gross Weight
270 kg | 595 lb
340 kg | 750 lb
370 kg | 815 lb
Pharmaceutical QC Academic & Research Microbiology & Bioprocess Clinical & Diagnostic Labs
FAQ

What is a Class II Type A2 biosafety cabinet?

The NSF Certified Class II Type A2 Biosafety Cabinet provides personnel, product, and environmental protection using inward inflow and HEPA-filtered laminar downflow. It is suitable for work with agents that require BSL-1, BSL-2, or BSL-3 practices where low levels of volatile toxic chemicals are not used.
How is this different from a laminar flow clean bench or fume hood?

A clean bench does not protect the user and exhausts unfiltered air; a chemical fume hood does not protect the product. The NSF Certified Class II Type A2 Biosafety Cabinet protects all three by HEPA-filtering downflow and exhaust air.
What can’t I use inside the BSC?

Do not use open flames, flammable/explosive or volatile toxic chemicals. Minimal use (≤10 mL) of 70% IPA/EtOH for surface disinfection is acceptable. Always follow your SOPs and the guidance that accompanies the NSF Certified Class II Type A2 Biosafety Cabinet .
What are the recommended pre- and post-use steps?

Close sash and run UV for ~30 minutes before work; set sash to 10" tested opening and allow ~10 minutes of airflow stabilization; after work, close sash and run UV another ~30 minutes. These steps help maintain the performance of the NSF Certified Class II Type A2 Biosafety Cabinet .
This applies to your NSF Certified Class II Type A2 Biosafety Cabinet order as well.

Specifications

Frequently asked questions

What sizes are available?+

3 ft, 4 ft and 6 ft.

What protection does a Class II Type A2 cabinet give?+

Personnel, product and environmental protection for handling infectious or potentially infectious materials, with all exhaust air HEPA filtered prior to release.

How does it differ from a clean bench or a fume hood?+

A clean bench blows unfiltered air toward the user and a chemical fume hood gives no product protection. A Class II Type A2 cabinet provides both personnel and product protection.

What standard does it meet?+

The manufacturer states it meets NSF/ANSI 49 performance criteria and is NSF certified.

Does it come with a stand?+

Yes — a detachable stand is included.

Related products

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →