Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this

CASRAI is the reference for research administration — bookmark it for the next question.

-40°C to 200°C 6L Heater Chiller UHC-10/40 - For 10L Reactors

SKU UHC-1040

USA Lab

-40°C to 200°C 6L Heater Chiller UHC-10/40 - For 10L Reactors

in Chiller/Heater Combos

$7,199.00

In stock

Closed-loop heater-chiller covering −40 °C to 200 °C from a 6 L reservoir, sized by the manufacturer for 10 L jacketed reactors.

Buying through procurement?

Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.

Ordering several items? Add them to your cart, then create one quote for the whole cart.

Description

The UHC-10/40 is a powerful -40°C to 200°C Heater Chiller with a 6L Reservoir. This heater chiller is ideal for applications involving vacuum systems, a jacketed 10l reactor, rotary evaporators, columns, solvent tanks, and even analytical instruments. These units are “Closed loop” and have a small in-feed hole allowing for the entire fluid reservoir to be closed off from the outside environment. The UHC heater chillers have easily accessible control panels for easy adjustments and repair.

The UHC-10/40 heater chiller offer unbeatable performance, ease of use and high reliability. These units keep quiet despite having a powerful pump allowing for constant flow rates to match the needs of demanding applications.

** Notice **NOT Compatible With 208V Power Input (Acceptable range: 219V – 253V)
NOT intended for 24-hour operation, maximum operation time is 16 hours.

*It may be necessary to add an external bypass*

MANUAL LINK

UHC-10/40 Specifications

Reservoir Capacity

6L

Temperature Range

Room Temperatureto -40°C to 200°C

Power Requirements

220-240V 60Hz 30A
5kW Single Phase6-20p (Does not pull peak amperage)

Heating Wattage

3kW

Refrigerating Wattage

1.9kW

Circulating Pump Wattage

100W

Temperature Accuracy

+/- 2°C

Pump Flow

18L/Min

Pump Pressure

6.5 PSI

Lift/height

6m/18ft

Connection Size

3/4″

Refrigerant

R-448 (2025+)

Dimensions

25″ x 22″ x 42″

Weight

187lbs

UHC-10/40 Packing List

Item

Quantity

UHC-10/40 Heater Chiller

1

3/4″ Insulated Tubing – 6ft

2

3/4″ Valve

1

3/4″ NPT Hex

1

PTFE Sealing Tape

1

Frequently asked questions

What temperature range does it cover?+

−40 °C to 200 °C from a single unit.

What size is the reservoir?+

6 L.

Which reactor is it sized for?+

USA Lab list the UHC-10/40 for their 10 L reactors.

What does closed loop mean here?+

A small in-feed hole allows the entire fluid reservoir to be closed off from the outside environment.

What supply voltage does it need?+

The notice states it is NOT compatible with 208 V input; the acceptable range is 219–253 V.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →