Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this

CASRAI is the reference for research administration — bookmark it for the next question.

HUBER CS Chillers

Huber

HUBER CS Chillers

in Chillers

$18,350.00 - $67,900.00

In stock

Price varies by Option and Certification.

Eight air-cooled recirculating chillers from the 3.5 kW CS 25 to the 28 kW CS 200. Standard models run −20 to +15 °C; -H variants heat to +85 °C.

Option
Certification

Choose Option and Certification to continue.

Buying through procurement?

Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.

Choose Option and Certification to continue.

Description

The Huber CS Series are compact, affordable recirculating chillers that combine “cool + smart” technology to slash water consumption and operating costs. With working temperatures from -20 °C to +15 °C (up to +85 °C on H models) and cooling power to 28 kW, CS units deliver reliable, closed-loop temperature control for labs and pilot plants.
Quiet (<79 dB), maintenance-free operation and robust pump performance (up to 125 L/min) make the CS Series ideal for cooling vacuum pumps, rotary evaporators, electron microscopy, AAS/ICP instruments, extraction, distillation, and more.
Choose from multiple footprints and voltages to match your process requirements and facility power.

Note: Verify heat load and ΔT to size correctly.
-20 °C to +15 °C (up to +85 °C on H) Cooling Power up to 28 kW Pump up to 125 L/min Quiet <79 dB Maintenance-Free Water-Saving, Eco-Smart
Efficient Cooling: Closed-loop design eliminates costly once-through water use.
Wide Temperature Range: −20 °C to +15 °C (H models up to +85 °C).
High Throughput: Up to 28 kW cooling power and 125 L/min pump capacity.
CS Series Data Sheets
Why Huber CS Series Recirculating Chillers?

Cool & Smart Efficiency — Reduce water use and lower operating costs with closed-loop cooling.
Broad Model Range — CS 25 to CS 200 cover 3.5 kW to 28 kW cooling, with H versions adding heating.
Strong Pumping — Up to 125 L/min and 4.2 bar for long runs and multi-tool manifolds.
Quiet & Low-Touch — <79 dB operation and maintenance-free components keep uptime high.
Technical Specifications
Cat. No.
Model
Temp. range (°C)
Pump capacity max. (l/min)
(bar)
pump connection
Cooling power (kW) at (°C)
Heating power (kW)
Noise level (dB)
Dimensions W × D × H (inch)
Voltage
Data sheet (PDF)
15
10
0
-10
-20
VDH1100664
CS 25
-20…15
50
4.5
1/2"
3.5
2.5
2
0.98
0.7

60
22.8 × 26.0 × 32.3
208V 2 ~ 60Hz
VDH1101336
CS 35
-20…15
30
4
1/2"
4
3.5
2
2
0.8

62
22.8 × 26.0 × 32.5
208V 2 ~ 60Hz
VDH1100689
CS 50
-20…15
83
4
3/4"
8
5
4
3.5
2

63
26.8 × 28.7 × 59.8
460V 3 ~ 60Hz *
VDH4100126
CS 50-H
-20…85
83
3.7
3/4"
8
5
4
3.5
2
2.8
63
26.8 × 28.7 × 59.8
460V 3 ~ 60Hz *
VDH1100690
CS 100
-20…15
83
4
3/4"
18
10
10
7.5
4.5

70
31.5 × 33.5 × 65.6
460V 3 ~ 60Hz *
VDH4100106
CS 100-H
-20…85
83
3.7
3/4"
18
10
10
7.5
4.5
5.5
70
31.5 × 33.5 × 65.6
460V 3 ~ 60Hz *
VDH1100688
CS 200
-20…15
125
4.2
1"
28
20
18
15
9.5

78
55.1 × 39.4 × 70.9
460V 3 ~ 60Hz
VDH4100091
CS 200-H
-20…85
125
4.2
1"
28
20
18
15
9.5
5.5
78
55.1 × 39.4 × 70.9
460V 3 ~ 60Hz
FAQ

What are the key benefits of the Huber CS Series Recirculating Chillers?

The Huber CS Series Recirculating Chillers deliver water-saving, closed-loop cooling with quiet, maintenance-free operation and broad model coverage from CS 25 to CS 200 for loads up to 28 kW.
Do Huber CS Series models offer heating as well as cooling?

Yes. The Huber CS Series Recirculating Chillers with the “H” suffix (CS 50-H, CS 100-H, CS 200-H) include integrated heating capability up to approximately 5.5 kW with working temperatures to +85 °C.
How do I size a Huber CS Series Recirculating Chiller for my process?

Provide your heat load (kW), target outlet temperature, and allowable ΔT. Our team will recommend the appropriate Huber CS Series Recirculating Chiller and share performance curves for your conditions.
Which applications suit the Huber CS Series Recirculating Chillers?

The Huber CS Series Recirculating Chillers are commonly used for rotary evaporators, vacuum pumps, electron microscopy, AAS/ICP instruments, extraction, and distillation where stable, closed-loop cooling is required.

Frequently asked questions

What is the difference between a CS model and a CS -H model?+

The -H variants (CS 50-H, CS 100-H, CS 200-H) add an integral heater and extend the working range from −20…+15 °C to −20…+85 °C. Heating power is 2.8 kW on the CS 50-H and 5.5 kW on both the CS 100-H and CS 200-H. Cooling performance is otherwise the same as the equivalent non-H model.

How much cooling does each model deliver?+

At 20 °C ambient: CS 25 3.5 kW, CS 35 4 kW, CS 50 and CS 50-H 8 kW, CS 100 and CS 100-H 18 kW, CS 200 and CS 200-H 28 kW. Capacity falls as the setpoint drops — the CS 25, for example, delivers 0.98 kW at −10 °C and 0.7 kW at −20 °C — and Huber notes that capacity may also drop as ambient temperature rises above 20 °C.

What electrical supply does each model need?+

The CS 25 and CS 35 run on 208 V 2~ 60 Hz. The CS 50, CS 50-H, CS 100 and CS 100-H are supplied for 208 V 3~ 60 Hz and are convertible to 460 V 3~ 60 Hz; only the CS 200 and CS 200-H are 460 V 3~ 60 Hz outright. Current draw ranges from 12.5 A on the CS 25 (2 × 20 A fusing) to 49 A on the CS 200-H (3 × 60 A fusing). Confirm available supply before selecting a model, as the step from CS 35 to CS 50 changes from two-phase to three-phase service.

What thermofluid should be used, and how much is needed?+

The Huber data sheets recommend a 50:50 water / monoethylene glycol mixture. Fill volumes scale with the model: the CS 25 takes a minimum of 24 litres and a maximum of 37 litres, while the CS 200-H takes a minimum of 225 litres and a maximum of 245 litres.

What is included with the chiller?+

Each data sheet lists two hose nozzles (Ø13 mm on the CS 25, Ø25 mm on the CS 200-H), a bath cover and a bypass valve. The bypass valve is mounted on the rear of the chiller and is how the flow rate is set manually. An overpressure bypass valve, drain valve, RS232 cable, hoses and heat transfer fluid are listed as optional.

What does the second purchase option change?+

The two options for each model differ only by a -UL suffix on the order number — VDH1100664 versus VDH1100664-UL on the CS 25, for example — at a $500 difference. The product data does not record what the suffix covers, so confirm the exact listing mark and file number with the supplier before citing it in an electrical-safety submission.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →