Answers are AI-generated from CASRAI’s own published pages and can be wrong, so check the linked sources before relying on one; your question is logged without personal data — never sold, never used to train a third-party model — to show us what CASRAI is missing, so please do not type personal or confidential details. How we use this
CASRAI is the reference for research administration — bookmark it for the next question.

SKU USA-VC-001
USA Lab
Vacuum Controller
$1,399.00
In stockDigital vacuum controller with an isolated sensor and industrial valving, for closed-loop set-point control on rotary evaporation, drying and filtration.
Buying through procurement?
Generate a formal quotation for 1 × this item, plus our W-9 — everything your finance department needs to raise a purchase order.
Ordering several items? Add them to your cart, then create one quote for the whole cart.
Description
The Vacuum Controller (VC-001) is a robust, modern instrument for accurate vacuum measurement and closed-loop control. Built with an isolated digital vacuum sensor, reliable valves, and industrial plumbing, it simplifies set-point regulation across rotary evaporation, vacuum drying, filtration, and R&D processes.
A bright 4.3" touch interface paired with large tactile buttons makes operation straightforward. Maintain precise saturation pressure with ±1 mbar adjustment accuracy and fine control down to 0.1 kPa increments. Compatible with diaphragm pumps, rotary vane pumps, circulating water vacuum pumps, and more.
Program control modes, continuous pumping, and one-click pressure release help you stabilize sensitive chemistries and improve repeatability.
Verify fittings and materials compatibility before integration.
±1 mbar Accuracy 0–1013 mbar Range 4.3" Touch + Buttons Set-Point & Program Control Isolated Digital Sensor 8 mm Barb Connection
Precise control: ±1 mbar adjustment accuracy; fine tuning to 0.1 kPa for consistent process pressure.
Broad compatibility: Works with diaphragm, rotary vane, and circulating water vacuum pumps.
Smart operation: Program control, continuous mode, and one-click pressure release improve throughput.
User Manual
Why the Vacuum Controller (VC-001)?
Precise vacuum control — Regulates pressure within ±1 mbar; ideal for rotary evaporation and decompression reactions.
Isolated digital sensor — Stable, accurate readings with robust valve and plumbing components.
Program & continuous modes — Maintain set-points, run profiles, or hold steady vacuum with one click pressure release.
Universal connectivity — 8 mm barb (pagoda) joint integrates with common lab tubing and traps.
User-friendly interface — 4.3" touch screen with large tactile buttons for gloved operation.
Technical Specifications
Model
Vacuum Controller (VC-001)
Measurement Range
0–1013 mbar (0–101.3 kPa)
Adjustment Accuracy
±1 mbar (fine control increments to 0.1 kPa)
Display
4.3" touch screen with large tactile buttons
Functions
Program control, continuous pumping, one-click pressure release
Connection
8 mm (3/8") pagoda (barb) joint
Ambient Temperature
5–40 °C
Relative Humidity
≤ 80% RH
Protection Class
IP21
Dimensions (W×D×H)
130 × 100 × 164 mm
Pressure Units
hPa, mbar, mmHg
Pump Compatibility
Diaphragm, rotary vane, circulating water vacuum pumps
Rotary Evaporation Vacuum Drying Short-Path Distillation Filtration & Degassing
FAQ
What is the Vacuum Controller (VC-001)?
The Vacuum Controller (VC-001) is a digital vacuum measurement and control device that maintains precise set-points for applications like rotary evaporation, drying, and filtration.
How precise is the Vacuum Controller (VC-001)?
It offers adjustment accuracy of ±1 mbar with fine control increments to 0.1 kPa, enabling stable saturation pressure and repeatable results.
Which pumps work with the Vacuum Controller (VC-001)?
It is compatible with most diaphragm, rotary vane, and circulating water vacuum pumps when plumbed with the included 8 mm barb connection and appropriate traps/filters.
Does the Vacuum Controller (VC-001) support set-points and programs?
Yes. It includes program control, continuous pumping, and a one-click pressure release function for fast adjustments and process safety.
Specifications
Power Requirements:
110-120V 50-60Hz
Frequently asked questions
What does closed-loop control mean here?+
The controller measures vacuum and actuates its valves to hold a set point, rather than only displaying a reading.
What is the sensor?+
An isolated digital vacuum sensor, paired with what USA Lab describe as reliable valves and industrial plumbing.
What processes is it intended for?+
USA Lab list rotary evaporation, vacuum drying, filtration and R&D processes.
What is the part number?+
USA-VC-001.
Related products

FYRA Vacuum Regulator | 10 millitorr to 6 Torr | 2 Sensors for Roughing Pump + System, UL, CSA,CE
DigiVac FYRA configured as a two-sensor vacuum regulator, listed for 10 millitorr to 6 Torr with sensors for both the roughing pump and the system. Control is by upper and lower set points driving a 24 VDC valve directly, with a 3.9 in touchscreen, USB and 0-10 V analogue in and out. WiFi is a selectable option. 100-240 VAC 50/60 Hz; UL, CE and CSA.