Shop cordis catheter central line supplies
- FDA registered
- ISO 13485
- BBB Accredited A+
Shop at LAC Health
Direct comparison
Cordis Catheter vs Central Line: Differences
Cordis catheter vs central line: FDA defines an introducer sheath by role, CDC NHSN defines a central line by tip location and use. Sourced table.
Written and maintained by CASRAI Editorial Board
Last updated
How do Introducer sheath (what searches call a "Cordis") and Central line / intravascular catheter compare side by side?
The table below compares Introducer sheath (what searches call a "Cordis") and Central line / intravascular catheter across 10 dimensions, from fda regulation name to which term to use.
Side-by-side comparison
| Dimension | Introducer sheath (what searches call a "Cordis") | Central line / intravascular catheter |
|---|---|---|
| FDA regulation name | Catheter introducer (21 CFR 870.1340) | Intravascular catheter (21 CFR 880.5200) |
| FDA identification | A sheath used to facilitate placing a catheter through the skin into a vein or artery. | A device consisting of a slender tube and any necessary connecting fittings, inserted into the vascular system for short-term use (less than 30 days) to sample blood, monitor blood pressure, or administer fluids intravenously. |
| FDA class | Class II (performance standards) | Class II (performance standards) |
| Example FDA product codes (openFDA, read 2026-11-01) | DYB Introducer, Catheter; OEX Cardiovascular Catheter Sheath Introducer Kit; OFL Percutaneous Sheath Introducer Kit | FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days; SEF Central Venous Catheter With Manual Insertion System |
| What the label describes | A device type, defined by its role as a passage for placing a catheter. | A line status for surveillance: the "central line" label depends on tip location and use, not on a brand or device type. |
| CDC NHSN central line definition | May count as a central line: NHSN names introducers among intravascular catheters that, depending on tip location and use, may be considered a central line. | An intravascular catheter that terminates at, in, or close to the heart, or in one of the great vessels, and is used for infusion, withdrawal of blood, or hemodynamic monitoring. |
| Does device type or insertion site decide? | No. NHSN states neither the type of device nor the insertion site is used to decide whether a device is a central line. | No. The same rule applies: tip location and use decide. |
| Great vessels NHSN lists | Not a property of the sheath itself; it applies to where the tip ends. | Aorta, pulmonary artery, superior vena cava, inferior vena cava, brachiocephalic veins, internal jugular veins, subclavian veins, external iliac veins, common iliac veins, femoral veins (umbilical artery or vein in neonates). |
| Related CASRAI pages | Introducer sheath: FDA class and product codes; guide wire types and sizes | Arterial line vs central line; PICC line; Broviac catheter; hemodynamic monitoring |
| Which term to use | Use "introducer sheath" or "catheter introducer" when naming or searching for the product, including FDA product-code searches. | Use "central line" when the question is where the tip ends and what the line is used for, for example when applying a surveillance definition. |
Sources
- FDA, 21 CFR 870.1340, eCFR, read 2026-11-01
- openFDA device classification, read 2026-11-01
- CDC NHSN Patient Safety Component Manual, Chapter 4 (BSI/CLABSI), January 2026, read 2026-11-01
- FDA, 21 CFR 880.5200, eCFR, read 2026-11-01
Ask CASRAI · free to try
Ask about Cordis Catheter vs Central Line: Differences
2 free questions a day, no account.
An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.
Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.
Works on this site and inside Claude, Cursor and the AI tools you already use.
Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.
Common questions
Common questions about Introducer sheath (what searches call a "Cordis") vs Central line / intravascular catheter
Is a Cordis catheter a central line?
+
It can be, depending on the tip and use. CDC NHSN defines a central line as an intravascular catheter that terminates at, in, or close to the heart or in one of the great vessels and is used for infusion, withdrawal of blood, or hemodynamic monitoring. It adds that neither device type nor insertion site decides this, and that introducers may be considered a central line depending on tip location and use.
What is the difference between a sheath and a catheter?
+
FDA identifies a catheter introducer as a sheath used to facilitate placing a catheter through the skin into a vein or artery (21 CFR 870.1340). It identifies an intravascular catheter as a slender tube with fittings inserted into the vascular system for short-term use (less than 30 days) to sample blood, monitor blood pressure, or administer fluids intravenously (21 CFR 880.5200). Both are Class II.
Is "central line" a type of device?
+
Not in the NHSN definition. NHSN says neither the type of device nor the insertion site is used to decide whether a device is a central line; tip location and use decide.
Which FDA product codes cover introducer sheaths?
+
Under 21 CFR 870.1340, openFDA lists codes including DYB (Introducer, Catheter), OEX (Cardiovascular Catheter Sheath Introducer Kit), OFC and OFD (Catheter Introducer Kit) and OFL (Percutaneous Sheath Introducer Kit), read 2026-11-01. See the introducer sheath guide for more.