Groshong Catheter vs Hickman: Valve vs Cuff

Groshong catheter vs Hickman in BD's own wording: valve versus cuff and clamp, both non-power injectable, plus the one 1992 head-to-head study.

Written and maintained by CASRAI Editorial Board

Last updated

Ask CASRAI · free to try

Ask about Groshong Catheter vs Hickman: Valve vs Cuff

Ask your first 2 questions free below. Subscribers get 150 a day for $29 a month.

An AI assistant specialized in research administration. It cites the sources behind every answer, labels web answers and says when it can't answer.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

How do Groshong catheter, Hickman catheter compare side by side?

The table below compares Groshong catheter, Hickman catheter across 12 procurement-relevant dimensions, from defining design feature (bd wording) through source.

Side-by-side comparison

DimensionGroshong catheterHickman catheter
Defining design feature (BD wording)Valve: BD lists "Negative pressure opens valve inward", "Positive pressure opens valve outward" and "At neutral pressure, valve remains closed".Cuff and clamp: BD's tray lists a radiopaque silicone catheter with a SureCuff tissue ingrowth cuff and clamp. BD's Hickman/Broviac feature list does not describe a pressure-responsive valve.
Flushing frequency (BD wording)BD lists "Decreased flushing frequency" among the Groshong features.No flushing-frequency feature appears on BD's Hickman/Broviac page.
Lumens listed by BDSingle and dual lumen listings.Single, dual and triple lumen catheters.
Tissue ingrowth cuffSome listings are described as including a SureCuff tissue ingrowth cuff with a peel-apart introducer.Tray includes a SureCuff tissue ingrowth cuff; BD says the cuff "promotes tissue growth to secure catheter placement".
ClampsBD's Groshong page does not mention clamps.BD says plastic clamps and protective sleeves "help prevent catheter damage".
Power injectionLabeled "Non-Power Injectable".Labeled "Non-Power Injectable CVC".
Infusion pressure limit (BD brochure)Not stated on the BD Groshong page.BD brochure: infusion pressure greater than 25 psi (172 kPa) is not recommended.
Material and tipNot stated on the BD Groshong page.Silicone; BD lists a soft silicone atraumatic tip and radiopaque silicone construction.
Stated intended useNot stated on the BD Groshong page; the instructions for use govern indications.BD brochure: designed for long-term vascular access and for patients who lack adequate peripheral venous access. Intended for single patient use; do not reuse.
Head-to-head evidence (1992)Pasquale et al. found no significant difference from the Hickman in septic complications or thrombus formation in cancer patients; the Groshong had more malfunctions, especially one-way intermittent malfunction.Same study: significantly fewer malfunctions than the Groshong. The authors wrote that the Hickman "appears to be a more favorable alternative" on catheter function. One small study from 1992; device designs and practice have changed since.
When each fitsA Groshong is the valve design in this comparison. Whether it suits a patient is decided by the clinician against the product's instructions for use.A Hickman is the cuff-and-clamp design in this comparison. Whether it suits a patient is decided by the clinician against the product instructions for use.
SourceBD Groshong product family page, read 2026-10-30; Pasquale et al. 1992 (PMID 1570619).BD Hickman/Broviac product family page and brochure BD-19819, read 2026-10-30; Pasquale et al. 1992 (PMID 1570619).

Common questions

Common questions about Groshong catheter vs Hickman catheter

What is the main difference between a Groshong and a Hickman catheter?

+

In BD's own product wording, the Groshong is characterised by a pressure-responsive valve (opens inward with negative pressure, outward with positive pressure, closed at neutral pressure), while the Hickman tray is characterised by a SureCuff tissue ingrowth cuff and plastic clamps. This is general product information, not medical advice.

Are Groshong and Hickman catheters power injectable?

+

BD labels its Groshong central venous catheters "Non-Power Injectable" and describes its Hickman/Broviac catheters as "Non-Power Injectable CVC" (product pages read 2026-10-30).

Did any study compare Groshong and Hickman catheters directly?

+

Pasquale, Campbell and Magnant, Surg Gynecol Obstet 1992;174(5):408-10 (PMID 1570619), compared them in cancer patients: no significant difference in septic complications or thrombus, and significantly fewer malfunctions with the Hickman. It is a single study from 1992.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →