Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop 512 hz tuning fork supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

512 Hz Tuning Fork: Hearing Test Use and Class I Status

What a 512 Hz (C512) tuning fork is, its Class I status under 21 CFR 882.1525, and how its Weber and Rinne accuracy compares with a 256 Hz fork.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

A 512 Hz tuning fork (often sold as a C512 fork) is a hand-held clinical instrument used in bedside hearing tests. This guide is for clinic staff, buyers and students who need to know what the fork is for, how it is regulated, and what the evidence says about its accuracy compared with a 256 Hz fork.

What a 512 Hz (C512) tuning fork is

A 512 Hz tuning fork is a tuning fork that vibrates at 512 cycles per second. In the United States, 21 CFR 882.1525 defines a tuning fork as “a mechanical device which resonates at a given frequency and is used to diagnose hearing disorders and to test for vibratory sense.” Clinicians use it mainly for the Weber and Rinne hearing tests. Who uses it: audiologists, otolaryngology (ear, nose and throat) clinicians, primary care and neurology examiners, and students learning the bedside examination.

“C512” is a name variant: it refers to the 512 Hz fork, not a different device. The 512 Hz in the name is the frequency of the fork itself. An audiometer’s bone oscillator is a separate device; the Hearing Review article on tuning forks notes that a 500 Hz setting means a 500 Hz tone from the audiometer’s bone oscillator, while 512 Hz is the tuning fork frequency. For general background on the instrument, see what a tuning fork is; for the 128 Hz fork, see the 128 Hz tuning fork guide.

Regulatory class: Class I under 21 CFR 882.1525

The U.S. regulation is not frequency-specific, so the same classification applies to a fork of any frequency, including 512 Hz.

Item What 21 CFR 882.1525 says
Intended use Diagnosing hearing disorders and testing for vibratory sense
Class Class I, general controls
Premarket notification Exempt from 510(k) (subpart E of part 807), subject to the limitations in 21 CFR 882.9
Quality management system Exempt from part 820, except for the records and complaint-file requirements of 21 CFR 820.35

The regulation covers only diagnosing hearing disorders and testing vibratory sense. Other claims made about forks by some sellers are not part of this classification.

How a 512 Hz fork is used: Weber and Rinne

The Weber and Rinne tests compare how a vibrating fork is heard through bone conduction and through air conduction. Hearing Review’s “Tuning forks revisited” article gives the rationale for 512 Hz and 1024 Hz as the preferred frequencies for administering the Weber and Rinne tests. It also describes the tests as a way to verify audiometric results. Technique is taught in clinical training and set out in the manufacturer’s instructions for use; this page does not cover it.

512 Hz vs 256 Hz: what the evidence shows

A systematic review of 17 studies compared tuning fork tests with pure tone audiometry (Kelly et al., 2018, Otolaryngology-Head and Neck Surgery 159(2):220-230, as summarized in the ASHA Evidence Map). The figures below are ranges across the included studies, not guarantees for any one fork or examiner.

Measure 256 Hz fork 512 Hz fork
Rinne test sensitivity range 43-91% 16-87%
Rinne test specificity range 50-100% 55-100%
Weber test sensitivity Less sensitive than with 512 Hz More sensitive than with 256 Hz

Neither frequency is better on every measure: the review found the Weber test more sensitive with 512 Hz forks, while the Rinne test showed greater sensitivity (and lower specificity) with a 256 Hz fork.

Accuracy and limits

Across all forks in the review, the Weber test had sensitivity of 18-67% and specificity of 33-97%, and the Rinne test had sensitivity of 16-91% and specificity of 71-100%. Hearing Review also notes that at frequencies above 1000 Hz the air-bone gap has to be larger for the Rinne result to differ. These ranges are wide and vary by study, examiner and fork.

Safe use and handling basics

  • Hearing Review notes that an overdriven fork deviates from its fundamental frequency and produces distortion.
  • Follow the manufacturer’s instructions for use for your specific fork and your facility’s cleaning policy.

Common mistakes

  • Treating a 512 Hz fork and a 500 Hz audiometer bone-oscillator tone as the same thing.
  • Assuming the 128 Hz fork used for vibration sense is interchangeable with the 512 Hz fork used for hearing tests; see the 128 Hz guide.

Where it fits

A fork sits beside other bedside instruments, such as a reflex hammer, and below the formal testing done with audiometers. Diagnostic equipment of this kind is grouped under diagnostic, monitoring and imaging equipment.

FAQ

What is a C512 tuning fork?

C512 is another name for the 512 Hz tuning fork, the frequency Hearing Review identifies as a preferred one for the Weber and Rinne tests.

Is a 512 Hz tuning fork a regulated medical device?

Yes. Under 21 CFR 882.1525 a tuning fork is Class I and exempt from 510(k) premarket notification, subject to the limitations in 21 CFR 882.9. The rule does not depend on frequency.

Is 512 Hz or 256 Hz better for the Weber test?

In the Kelly et al. (2018) systematic review, the Weber test was more sensitive with 512 Hz forks than with 256 Hz forks.

Is a 512 Hz fork the same as a 500 Hz audiometer tone?

No. 500 Hz refers to a tone from the audiometer’s bone oscillator; 512 Hz is the frequency of the tuning fork.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about 512 Hz Tuning Fork: Hearing Test Use and Class I Status

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →