Acetic anhydride (CAS 108-24-7) is a flammable, corrosive liquid that reacts violently with water, and the safety data sheets (SDSs) that suppliers publish for it agree on that core but not on everything else. All five documents compared here classify it as a flammable liquid (flash point 49 °C) and as causing severe skin burns and eye damage, and all list harm if swallowed. They differ on how toxic the vapour is (Category 2 “fatal if inhaled” on two sheets, Category 4 “harmful if inhaled” on two others), on glove advice, and on which materials count as incompatible.
This page summarises what the sheets say and shows where they diverge, for lab staff and environmental health and safety (EHS) officers. It does not replace the sheet supplied with your own lot of material, which is the document your risk assessment and chemical hygiene plan should cite.
Short answer: what the acetic anhydride SDS classifies
The 2023 International Chemical Safety Card (ICSC 0209, ILO and WHO) lists acetic anhydride under UN number 1715, UN hazard class 8 (corrosive) with subsidiary class 3 (flammable), packing group II. The GHS signal word on the sheets is Danger. Across the sheets read for this page, the hazard statements that appear are:
- H226, flammable liquid and vapour: on the Columbus Chemical, Cayman Chemical, EMD Millipore and Sigma-Aldrich sheets.
- H302, harmful if swallowed: on the same four sheets.
- H314, causes severe skin burns and eye damage (skin corrosion Category 1B): on the same four sheets.
- H330 or H332, inhalation toxicity, with the category depending on the supplier (see below).
- H318 (serious eye damage Category 1) on the EMD Millipore and Sigma-Aldrich sheets, and H335 (may cause respiratory irritation) on the Columbus Chemical sheet.
The data table below compares the five documents side by side, with each sheet’s revision date. Revision dates run from 2018 to 2026, so part of any difference may reflect when a sheet was written rather than a real difference between products.
Why the sheets disagree on inhalation toxicity
The largest single divergence is the inhalation classification. The EMD Millipore sheet (AX0080, revised 13 August 2018) and the Sigma-Aldrich sheet (revised 11 May 2021) classify acute inhalation toxicity as Category 2 with H330, “Fatal if inhaled”, and the EMD sheet adds precautionary statement P284 (wear respiratory protection). The Columbus Chemical sheet (revised 4 September 2024) and the Cayman Chemical sheet (revised 20 July 2026) classify it as Category 4 with H332, “Harmful if inhaled”. ICSC 0209 describes it as “toxic if inhaled” and adds that it causes damage to the lungs if inhaled.
The sheets themselves do not explain the gap, so it should not be explained away here either. What a reader can say from the documents is that the same substance is described at three different severity levels, and that those levels carry different consequences for respiratory protection, fume hood use and exposure monitoring. The practical reading for an EHS officer is editorial rather than regulatory: when the sheets for the same chemical disagree, base the local control decision on the more protective classification unless a written assessment says otherwise, and cite the sheet that came with the lot actually in the building. Do not average the sheets, and do not treat a database mirror as equivalent to the supplier’s sheet for your catalogue number.
Where this matters most is ventilation. For a chemical classified H330, a fume hood is the control a risk assessment would start from, and the ICSC entry adds a second reason: inhalation may cause asthma-like reactions (reactive airways dysfunction syndrome) and lung oedema, with symptoms that can be delayed. The same entry describes the liquid as a lachrymator, an irritant to the eyes that causes tearing, and the Sigma-Aldrich sheet carries the same word.
Physical hazards: flammability and water reactivity
ICSC 0209 gives a flash point of 49 °C (closed cup), an autoignition temperature of 316 °C and explosive limits of 2.7 to 10.3 per cent by volume in air. Its boiling point is 139 °C, melting point -73 °C and relative density 1.08. The vapour is 3.5 times as dense as air, and the vapour pressure is 0.5 kPa at 20 °C. The Columbus Chemical and Cayman Chemical sheets give the same 49 °C flash point (120.2 °F on the Columbus sheet).
The vapour density is why the card’s flammability guidance goes beyond “keep away from flames”: a vapour heavier than air can collect at low levels. The Columbus sheet’s storage section asks for the liquid to be kept away from heat, sparks, flame and other ignition sources, not stored near combustible materials, and kept in an area equipped with sprinklers.
Water is the second physical hazard. ICSC 0209 states that the substance reacts violently with water, strong bases, strong reducing agents and oxidants, with a fire or explosion hazard, and gives its solubility in water as a reaction that releases heat. The Sigma-Aldrich sheet says directly: “Reacts violently with water.” On burning, the card says the substance decomposes to carbon monoxide and toxic fumes, including acetic acid fumes.
The fire-fighting instruction that looks contradictory
A reader comparing the fire sections will find what looks like a conflict. ICSC 0209 says to use alcohol-resistant foam, powder or carbon dioxide, and that there must be no direct contact with water on the substance; the same card says to keep drums cool by spraying them with water. Read together, these are consistent: water is for cooling the outside of closed containers, never for application to the liquid itself. A site emergency plan that says only “use water” or only “never use water” for this chemical would not match the card.
Health hazards in the sheets
ICSC 0209 describes the substance as corrosive to the eyes, skin and respiratory tract, with lachrymation. The skin corrosion classification is Category 1B on every sheet that gives one, which means severe burns, and the EMD Millipore and Sigma-Aldrich sheets add Category 1 serious eye damage (H318). The oral hazard is H302, harmful if swallowed, on all four supplier sheets. The Cayman Chemical sheet prints the oral and inhalation statements as one combined line, H302+H332, so a reader scanning only the first hazard line of that sheet sees both Category 4 classifications together, while the Sigma-Aldrich and EMD Millipore sheets list H302 and H330 as separate lines at different severities, which is easy to miss when two sheets are compared quickly.
The card’s inhalation warning is the part most often missed by people who handle the liquid only in small volumes: the effects on the lungs may not appear at once. This page does not give first aid or treatment instructions; those belong to the first-aid section of the sheet for the lot in use and to your institution’s emergency procedures.
Personal protective equipment as the sheets state it
The PPE sections are where the sheets are least alike, and a comparison is more useful than a single recommendation.
- Sigma-Aldrich (2021): full-contact gloves of butyl rubber, 0.7 mm thick, with a breakthrough time of 480 minutes (KCL Butoject 898 test product); splash-contact gloves of latex, 0.6 mm, with a 60-minute breakthrough time (KCL Lapren 706). It also specifies tightly fitting safety goggles and flame-retardant antistatic clothing.
- EMD Millipore (2018): tightly fitting goggles, chemical-resistant impervious gloves chosen according to the risk assessment, flame-retardant antistatic clothing, and respiratory protection when vapours or aerosols are generated.
- Columbus Chemical (2024): “suitable gloves, impervious”, with no respiratory protection under normal use, but suitable equipment if exposure limits are exceeded.
- Cayman Chemical (2026): no glove material recommendation can be given for the product, because the tests are missing.
Only one sheet therefore names a glove material and a breakthrough time, and its splash-contact option has a shorter time than its full-contact option by a factor of eight. Where a sheet gives no material, the institution’s own glove-selection process under its chemical hygiene plan has to fill the gap; the SDS cannot.
Storage, incompatibilities and conditions to avoid
All sheets agree on tightly closed, dry, well-ventilated storage away from ignition sources. ICSC adds that the chemical should be kept only in its original container, separated from food and incompatible materials, in a fireproof, dry place. The EMD Millipore sheet adds locked storage or access restricted to authorised persons and room-temperature storage. The Sigma-Aldrich sheet gives German storage class (TRGS 510) 3, flammable liquids.
The lists of incompatible materials show the most variation:
- ICSC 0209: strong reducing agents, oxidants, strong bases and water, and it attacks many metals and plastics.
- Columbus Chemical: acids, bases and oxidising agents; conditions to avoid are heat, flames, sparks and prolonged exposure to air or moisture.
- EMD Millipore: iron and copper; condition to avoid is heating.
- Cayman Chemical: “No further relevant information available.”
An empty incompatibility field on one sheet is not evidence of compatibility. The storage rule that follows from reading all of them together is to separate the liquid from water, aqueous solutions, bases, oxidisers and reducing agents, and to check metal and plastic fittings against the sheet in use, because the card says many are attacked.
Spills, fire and disposal as stated
For spills, ICSC 0209 says to evacuate the danger area, remove all ignition sources, collect leaking liquid in sealable containers and absorb the remainder in sand or an inert absorbent. For disposal, the sheets point to the regulations rather than a single method: the Columbus sheet gives P501 (dispose to an approved waste disposal plant), the Cayman sheet says not to discharge the product to sewage or household garbage and to follow official regulations, and the EMD Millipore sheet says the waste generator is responsible for waste identification and for following regional, national and local law.
Exposure limits, source by source
Exposure limits on the sheets come from different bodies and are not interchangeable. The table lists each value with the document that reports it.
| Limit | Value | Reported on |
|---|---|---|
| ACGIH TLV, 8-hour TWA | 1 ppm | ICSC 0209, Columbus Chemical, Cayman Chemical, Sigma-Aldrich |
| ACGIH TLV, STEL | 3 ppm | ICSC 0209, Columbus Chemical, Cayman Chemical, Sigma-Aldrich |
| OSHA PEL, TWA | 5 ppm (20 mg/m³) | Columbus Chemical, Cayman Chemical (Sigma-Aldrich lists 5 ppm) |
| NIOSH REL, ceiling | 5 ppm | Cayman Chemical |
| MAK (German) | 0.1 ppm (0.42 mg/m³) | ICSC 0209 |
| Emergency PAC-1 / PAC-2 / PAC-3 | 0.50 / 15 / 100 ppm | Cayman Chemical |
The ICSC entry also carries the ACGIH carcinogenicity category A4 (not classifiable as a human carcinogen). The spread between the German MAK of 0.1 ppm, the ACGIH TWA of 1 ppm and the OSHA PEL of 5 ppm is a factor of 50, which is one reason a lab’s own exposure assessment should name which limit it applies and why. Columbus Chemical’s table also lists a vacated ceiling of 5 ppm.
Regulatory listing worth knowing
Acetic anhydride is also a precursor chemical under United States drug-control law. 21 CFR 1310.02(b) lists it as a List II chemical, DEA code 8519. This is a regulatory listing, not a GHS hazard classification, and it does not appear in the hazard sections of the sheets. Questions about purchasing or record-keeping belong to your institution’s compliance office.
A short checklist for reading any acetic anhydride SDS
- Confirm the CAS number 108-24-7 and the product grade, and note the revision date; the five sheets here span 2018 to 2026.
- Read Section 2 for the inhalation category (H330 versus H332) and decide the ventilation baseline from the stricter reading.
- Check Section 8 for a named glove material and breakthrough time; if none is given, escalate to your glove-selection process.
- Read the incompatibility lines in Section 10 together with the ICSC list, not alone.
- Match the fire and spill sections to the site emergency plan, including the water-cooling-only rule for drums.
- Record which sheet (supplier, product number, date) the lab’s risk assessment cites.
The same approach applies to the sheets for other common laboratory liquids; see, for example, the safety data sheet guides for ethyl acetate, nitric acid and hydrochloric acid.
Common misunderstandings
- “All SDSs for one chemical say the same thing.” The comparison above shows inhalation categories, glove advice and incompatibles that differ between suppliers for the same CAS number.
- “Water is always the wrong extinguishing medium.” The ICSC card forbids direct contact of water with the substance but allows water spray to cool drums.
- “A blank incompatibility field means nothing is incompatible.” The Cayman sheet’s “no further relevant information” sits against ICSC’s list of water, bases, oxidants and reducing agents.
- “It is only a flammable solvent.” It is classified as corrosive (UN class 8) with flammability as the subsidiary hazard.
- “No symptoms straight away means no harm.” ICSC 0209 states that lung effects of inhalation may be delayed.
Sources
- ILO and WHO: International Chemical Safety Card 0209, Acetic anhydride (2023 version), checked 2026-11-19
- Columbus Chemical: Safety Data Sheet, Acetic Anhydride, ACS 0090 (revised 4 September 2024), checked 2026-11-19
- Cayman Chemical: Safety Data Sheet 400031, Acetic Anhydride (revised 20 July 2026), checked 2026-11-19
- EMD Millipore: Safety Data Sheet AX0080, Acetic Anhydride GR ACS (revised 13 August 2018, hosted by the University of Washington), checked 2026-11-19
- Sigma-Aldrich: Safety Data Sheet, Acetic anhydride 108-24-7 (revised 11 May 2021, hosted by Organic Chemistry at CU Boulder), checked 2026-11-19
- Cornell Legal Information Institute: 21 CFR 1310.02, Substances covered, checked 2026-11-19
Data: Acetic anhydride (CAS 108-24-7): hazard statements and handling advice on five safety documents
Side-by-side comparison of what four supplier safety data sheets (Columbus Chemical, Cayman Chemical, EMD Millipore, Sigma-Aldrich) and the ILO/WHO International Chemical Safety Card 0209 state for acetic anhydride: inhalation classification, glove advice and incompatible materials. Compiled by reading each document in full on 2026-11-19; revision dates are included because they range from 2018 to 2026.
Period covered: 2018/2026.
| Document (revision) | Inhalation hazard as stated | Other classified hazards | Glove advice | Incompatibles or conditions to avoid |
|---|---|---|---|---|
| ILO/WHO ICSC 0209 (2023) | Toxic if inhaled; damage to lungs if inhaled | Flammable liquid and vapour; harmful if swallowed; severe skin burns and eye damage | Not stated in the card text | Reacts violently with strong reducing agents, oxidants, strong bases and water; attacks many metals and plastics |
| Columbus Chemical ACS 0090 (2024-09-04) | H332 Harmful if inhaled (Category 4); H335 respiratory irritation | H226, H302, H314 | Suitable gloves, impervious | Acids, bases, oxidizing agent; avoid heat, flames, sparks, prolonged exposure to air or moisture |
| Cayman Chemical 400031 (2026-07-20) | H332 Harmful if inhaled (Category 4) | H226, H302, H314 (Category 1B) | No glove material recommendation can be given (missing tests) | No further relevant information available |
| EMD Millipore AX0080 (2018-08-13) | H330 Fatal if inhaled (Category 2) | H226, H302, H314, H318 | Chemical-resistant impervious gloves per risk assessment | Iron, copper; avoid heating |
| Sigma-Aldrich (2021-05-11) | H330 Fatal if inhaled (Category 2) | H226, H302, H314, H318; reacts violently with water; lachrymator | Butyl rubber 0.7 mm, 480 min (full contact); latex 0.6 mm, 60 min (splash) | Reacts violently with water; storage class 3 (flammable liquids) |
Sources
- ILO/WHO ICSC 0209 Acetic anhydride (accessed 2026-11-19)
- Columbus Chemical SDS Acetic Anhydride ACS 0090 (accessed 2026-11-19)
- Cayman Chemical SDS 400031 (accessed 2026-11-19)
- EMD Millipore SDS AX0080 (accessed 2026-11-19)
- Sigma-Aldrich SDS Acetic anhydride 108-24-7 (accessed 2026-11-19)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.