Skip to main content
v2026.11,986 entries · CC-BY 4.0

Acoustic Phonetics: Measures, Formants and Spectrograms

Acoustic phonetics measures speech as sound: f0, formants, intensity and duration, with worked spectrogram arithmetic and reporting guidance.

Written and maintained by CASRAI Editorial Board

Published

On this page

Acoustic phonetics is the branch of phonetics that studies the physical properties of speech sounds as sound waves, describing them by their frequency, amplitude and duration. Researchers measure these properties from a recording, usually as fundamental frequency (f0, in hertz), formant frequencies (Hz), intensity (decibels) and segment duration (seconds or milliseconds), most often in software such as Praat. The sections below define each measure, work through the arithmetic that links time and frequency settings, and show how to report the results.

What is acoustic phonetics? Definition in one paragraph

The University of Sheffield’s linguistics department describes acoustic phonetics as the study of the physical properties of speech, analysed in terms of frequency, amplitude and duration. It sits alongside articulatory phonetics, which asks how speakers produce sounds with the speech organs, and it is a core method inside linguistics wherever a claim about speech needs a measurement rather than an impression. Because it works from recordings, an acoustic analysis can be repeated by another researcher with the same file and the same settings, which is the main reason it is used in quantitative speech research.

What is the definition of acoustic?

In this field, “acoustic” refers to the sound wave itself: the pressure variation that travels from speaker to microphone, as opposed to the movements that produced it or the perception it causes in a listener. An acoustic measure is therefore something read from the recorded signal, such as how many times the vocal folds open per second or where energy concentrates along the frequency axis.

What are the characteristics of phonetics?

Phonetics deals with the physical production of sounds, covering the organs involved and voicing. Sheffield’s overview contrasts it with phonology, which is concerned more with the abstract properties of sounds. A distinguishing characteristic is that phonetics treats properties as gradient: voicing, for example, is a matter of degree, and the department’s example is that a French [b] is voiced for longer than an English [b]. Phonetic description is therefore usually numerical (how long, how high, how intense) rather than a yes-or-no label.

What is the difference between phonetics and phonology?

Phonetics measures and describes the physical side of speech; phonology studies the abstract properties of sounds and how they pattern. In Sheffield’s illustration, phonetics records voicing as a matter of degree, whereas phonology treats a segment simply as voiced or voiceless. An acoustic phonetician might report that a consonant had 62 ms of voicing (an illustrative figure, not data); a phonologist would use that kind of evidence to decide whether the sound belongs to the voiced or the voiceless category in the language.

What are the acoustic features of speech?

Sheffield’s acoustic pages organise the measurable features of speech into frequency, amplitude and duration, each with its own unit.

Fundamental frequency (f0)

f0 is the rate at which the vocal folds open and close, equivalently the number of cycles in a periodic waveform, measured in hertz. A speaker whose vocal folds open 200 times per second has an f0 of 200 Hz. f0 is the main acoustic correlate of what listeners hear as pitch.

Formants

Formants are natural resonances of the vocal tract. On a spectrogram they appear as dark horizontal bands, and they are typical of vowels, approximants and nasals. Their frequencies shift as the tongue and lips change position, which is why formant measurements are used to describe vowel quality. In Praat, a formant object stores, for each analysis frame, the frequency and bandwidth of usually two to six formants.

Intensity and duration

Amplitude is reported as intensity in decibels (dB). Time is reported in seconds or milliseconds. Duration measures include the length of a vowel or the interval between a release and the start of voicing.

Reading a spectrogram

A spectrogram plots time on the horizontal axis and frequency on the vertical axis, with darkness showing amplitude. Unlike the waveform, it also displays the high-frequency energy of aperiodic sounds such as fricatives. Praat’s manual gives a standard dynamic range of 50 dB and a standard view range of 0 to 5000 Hz for the spectrogram display.

Formulas, with every symbol explained

Two relationships appear constantly in acoustic work. Both are taken from the sources listed at the end of the page.

Frequency and period

f0 = 1 / T, where f0 is the fundamental frequency in hertz (cycles per second) and T is the duration of one glottal cycle in seconds. Sheffield’s definition of f0 as openings of the vocal folds per second is exactly this relationship stated in words.

Spectrogram bandwidth and window length

For the Gaussian window Praat uses by default, the manual gives the -3 dB bandwidth as approximately 1.2982804 / L, where L is the analysis window length in seconds and the bandwidth is in hertz. A longer window gives finer frequency resolution but blurs time; a shorter window does the opposite.

Pitch analysis window

For Praat’s pitch analysis the manual states that the window is three longest periods long, so the window length is 3 / pitch floor. The standard pitch floor is 75 Hz and the standard ceiling is 600 Hz.

Worked example with the arithmetic shown

  1. Period to frequency. If one glottal cycle lasts T = 0.005 s (5 ms), then f0 = 1 / 0.005 = 200 Hz. This matches the Sheffield example of 200 openings per second. A cycle of 0.008 s gives 1 / 0.008 = 125 Hz.
  2. Wide-band spectrogram. Praat’s standard wide-band window is 5 ms, L = 0.005 s. Bandwidth = 1.2982804 / 0.005 = 259.66, so about 260 Hz, matching the roughly 260 Hz the manual reports.
  3. Narrow-band spectrogram. The narrow-band window is 30 ms, L = 0.030 s. Bandwidth = 1.2982804 / 0.030 = 43.28, so about 43 Hz, matching the manual.
  4. Pitch window at the default floor. 3 / 75 = 0.04 s, a 40 ms analysis window.

Comparing steps 2 and 3 shows the trade-off. The 30 ms window resolves frequencies about six times more finely (259.66 / 43.28 = 6.0) but spreads events over a six times longer stretch of time. The data table below collects these settings, with their units, in one place. The pitch window works the same way in reverse: raising the pitch floor to 150 Hz would shorten the window to 3 / 150 = 0.02 s, because a higher floor means shorter longest-period.

Interpreting the measures

Observation How to read it
Dark horizontal bands on a spectrogram Formants, the vocal-tract resonances typical of vowels, approximants and nasals (Sheffield).
A formant band moving up or down over time A change in tongue or lip position (Sheffield).
Wide-band display (5 ms window, about 260 Hz bandwidth) Sharper time detail, coarser frequency detail (Praat manual).
Narrow-band display (30 ms window, about 43 Hz bandwidth) Finer frequency detail, blurred time (Praat manual).
f0 value in Hz Number of vocal-fold cycles per second; the reciprocal of the period.

Assumptions and common mistakes

  • Using one formant ceiling for every speaker. The Praat manual recommends a ceiling of about 5000 Hz for adult male speakers, 5500 Hz (the default) for adult female speakers and about 8000 Hz for young children. Too high a ceiling can merge formants: the manual’s example is an [u] whose true formants near 300 and 600 Hz are read as a single formant near 500 Hz.
  • Counting the wrong number of formants. The manual advises five formants for most speech.
  • Confusing the window length with its effective duration. The manual’s example notes that a 0.025 s window setting corresponds to an actual analysis duration of 0.050 s, so check which one a tool reports.
  • Treating the spectrogram as ground truth. Its appearance depends on window length and dynamic range, so two spectrograms of the same sound with different settings can look different. Report the settings.
  • Treating phonetic gradience as phonological category. A measurement of degree of voicing is phonetic evidence; the category decision is a phonological one.

How to report acoustic measurements

Report the quantity, its unit, the software and its version, and every setting that affects the number: formant ceiling and number of formants, pitch floor and ceiling, window length and window shape. For participants, state the speaker group the ceiling was matched to. A format example in APA style follows; the numbers are placeholders showing the pattern, not results.

Mean f0 was 118.4 Hz (SD = 12.1) in the read-speech task. Formants were estimated in Praat using a 5500 Hz ceiling and five formants, with a 0.025 s window.

Give the exact Praat version you used and cite the program per its own citation guidance; see the Praat guide for how. Annotated recordings are often prepared in a tool such as ELAN, and public speech corpora such as LibriSpeech are used when no new recordings are made.

How to calculate the core quantities in Excel, R or Python

These snippets compute the relationships in the formulas section from a period or window length. They do not extract f0 from audio; for that, use a pitch tracker such as Praat’s.

Excel

A1: 0.005          (period T in seconds) B1: =1/A1          (f0 = 200 Hz) A2: 0.030          (window length L in seconds) B2: =1.2982804/A2  (bandwidth = 43.28 Hz)

R

T  = 0.005 f0 = 1 / T                # 200 L  = c(0.005, 0.030) bw = 1.2982804 / L        # 259.66  43.28 round(bw, 1)

Python

T = 0.005 f0 = 1 / T                 # 200.0 for L in (0.005, 0.030):     print(L, round(1.2982804 / L, 2))   # 259.66, 43.28

For spectrograms computed in code rather than Praat, see the SciPy spectrogram guide, where window length is again the parameter that trades time against frequency detail.

Frequently asked questions

What are the characteristics of phonetics?

It concerns the physical production of speech sounds, including the organs involved and voicing, and it describes properties as matters of degree rather than fixed categories.

What is the difference between phonetics and phonology?

Phonetics describes the physical properties of sounds, whereas phonology is concerned with their abstract properties, such as treating a segment as simply voiced or voiceless.

What are the acoustic features of speech?

Frequency (f0 and formants, in Hz), amplitude or intensity (dB) and duration (s or ms).

What is the definition of acoustic?

Relating to sound; in phonetics, to the physical sound wave of speech.

What does a spectrogram show?

Time on the horizontal axis, frequency on the vertical axis and amplitude as darkness, including the high-frequency energy of aperiodic sounds that a waveform does not show clearly.

Which formant ceiling should I use in Praat?

The manual recommends about 5000 Hz for adult males, 5500 Hz (default) for adult females and about 8000 Hz for young children.

Sources

Data: Praat analysis settings for acoustic phonetics: windows, bandwidths, ceilings

Default and recommended Praat analysis settings for spectrograms, formant and pitch analysis, compiled from the Praat manual, with spectrogram bandwidths computed from the manual's Gaussian window formula (1.2982804 / window length).

Period covered: 2026.

Praat analysis settings for acoustic phonetics: windows, bandwidths, ceilings
SettingPraat procedureValueUnit of value
Wide-band spectrogram windowSpectrogram0.005s
Wide-band spectrogram bandwidth (computed)Spectrogram259.7Hz
Narrow-band spectrogram windowSpectrogram0.03s
Narrow-band spectrogram bandwidth (computed)Spectrogram43.3Hz
Spectrogram dynamic range (standard)Spectrogram50dB
Spectrogram view range upper limit (standard)Spectrogram5000Hz
Formant ceiling, adult maleTo Formant (burg)5000Hz
Formant ceiling, adult female (default)To Formant (burg)5500Hz
Formant ceiling, young childTo Formant (burg)8000Hz
Pitch floor (standard)To Pitch75Hz
Pitch ceiling (standard)To Pitch600Hz
Pitch analysis window at 75 Hz floor (computed, 3 / floor)To Pitch0.04s

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Acoustic Phonetics: Measures, Formants and Spectrograms

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →