Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
General product information only, not medical advice. Your care team sets your goal, how often to use the device and when to stop. The manufacturer’s instructions for use (IFU) and your provider’s directions come first.
Who this is for: a patient, caregiver or supply staff member holding an AirLife volumetric incentive spirometer who wants to know what each part does, how the breathing steps go, and which model is in hand.
The short answer to “how to use an AirLife spirometer”: sit upright, hold the device level, seal your lips around the mouthpiece, breathe in slowly and steadily so the piston rises toward the goal marker your care team set, hold the breath briefly, breathe out, and rest. Repeat as your provider directs. This page covers the AirLife-specific parts, then the general steps. For the device type itself, see what an incentive spirometer is.
What you need
- The AirLife volumetric incentive spirometer, with its flexible tubing and swivel mouthpiece attached.
- The goal volume from your provider. The goal is set by the care team, not by this page.
- The instructions for use packed with the device or printed on its labelling. The manufacturer, Vyaire Medical, states that you should read the complete IFU that comes with the devices or follow the instructions on the product labelling.
What the AirLife markers mean
The Vyaire Medical brochure (VYR-GBL-2000412, checked 2026-11-01) describes these features, which map directly onto the steps below.
| Part | What the manufacturer says it does |
|---|---|
| Dual-sided calibrations (the chart on the chamber) | Identify achieved volumes, up to 4,000 mL capacity on the largest model. |
| Patient goal indicator | An adjustable indicator that provides a volumetric goal and lets patients monitor their own progress. |
| Inspiratory flow indicator | Encourages the patient to keep a slow, proper rate of inspiration. |
| Flexible tubing and swivel mouthpiece | The part you breathe through. |
| Mouthpiece holder | A place to store the mouthpiece when not in use. |
| Handle | Helps ensure patients use the spirometer upright; it can be placed on a bed rail. |
| One-way valve (on some models) | A reminder to inhale rather than exhale through the device. |
The goal is set by your provider, not by the device or by this page.
Steps
These steps paraphrase the general patient instructions from MedlinePlus (reviewed 10/19/2025, checked 2026-11-01), matched to the AirLife parts above.
- Sit upright on the edge of the bed or in a chair, and hold the spirometer level by its handle.
- Set the goal indicator to the volume your provider gave you.
- Breathe out normally.
- Seal your lips tightly around the mouthpiece.
- Breathe in slowly and steadily, watching the inspiratory flow indicator so you do not breathe in too fast, until the piston rises toward your goal marker.
- Hold your breath briefly if you can.
- Remove the mouthpiece, breathe out slowly, and rest. Place the mouthpiece in its holder.
- Repeat as your provider directs.
How to use an AirLife spirometer: common questions
How to use AirLife spirometer?
Follow the steps above: upright, lips sealed, slow steady breath in, a brief hold, breathe out, rest, repeat as directed. Use the goal indicator and the flow indicator as your guides.
How to use a AirLife?
This page covers the AirLife volumetric incentive spirometer, so the same steps apply. If you hold a different AirLife product, use the instructions packed with that product.
What is an AirLife spirometer chart?
It is the dual-sided volume scale on the chamber, which shows the volume you reached. Per the manufacturer it identifies achieved volumes up to 4,000 mL on the largest model.
What is an AirLife breather?
This page treats “AirLife breather” and “AirLife breathing” as the AirLife volumetric incentive spirometer described here, a device you breathe in through to see the volume you reach. Other AirLife products come with their own instructions.
Which model do you have?
The Vyaire Medical brochure lists these adult and pediatric versions by catalog number.
| Catalog no. | Capacity | One-way valve |
|---|---|---|
| 001901A | 4,000 mL | With |
| 001902A | 4,000 mL | Without |
| 001903A | 2,500 mL | With |
| 001904A | 2,500 mL | Without |
| 001905A | 2,500 mL pediatric | Included, with colorful targets |
The brochure lists these as sold 12 per case. The National Library of Medicine’s AccessGUDID record for the 2,500 mL model 001904A (checked 2026-11-01) lists FDA product code BWF, “Spirometer, Therapeutic (Incentive)”, and shows it packaged sterile and not requiring sterilization before use. The same record is marked single-use while its device description text describes reuse, so do not assume a reuse rule: follow the IFU, the product label and your facility’s policy. Related device pages: spirometer mouthpieces, peak flow meters (a different measurement tool) and the occupational medicine clinic supply checklist.
What can go wrong
- Breathing in too fast. The inspiratory flow indicator exists to encourage a slow, proper rate.
- Breathing out into the device. The optional one-way valve is a reminder to inhale rather than exhale.
- Holding it tilted. The handle helps ensure the device is used in an upright position.
- Wrong goal. Only your provider sets the target; do not choose one yourself.
- Lost or misplaced mouthpiece. Use the mouthpiece holder when not in use.
When to get professional help
MedlinePlus advises contacting your provider about any new or worsening symptoms. Also ask your care team if you are unsure how to use the device or have questions about cleaning or replacing it.
FAQ
How often should I use it?
As your provider directs. Your care team sets how often and how many breaths.
Where is the full AirLife IFU?
In the package or on the product labelling. Use the IFU for cleaning, reuse and storage questions, which this page does not answer.
How do I know which AirLife model I have?
Check the catalog number on the label against the table above: 001901A to 001905A differ by capacity (2,500 or 4,000 mL), one-way valve and pediatric version.
Sources
- Vyaire Medical, AirLife volumetric incentive spirometer brochure VYR-GBL-2000412 (2020), https://info.simplyrenting.com/sites/default/files/2022-05/vyr-gbl-2000412-volumetric-incentive-spirometer_final.pdf, checked 2026-11-01.
- National Library of Medicine, AccessGUDID record for AirLife Volumetric Incentive Spirometer 2500 ml (001904A), https://accessgudid.nlm.nih.gov/devices/10190752131071, checked 2026-11-01.
- MedlinePlus, “Using an incentive spirometer”, https://medlineplus.gov/ency/patientinstructions/000451.htm, reviewed 10/19/2025, checked 2026-11-01.