The Applied Biosystems High-Capacity cDNA Reverse Transcription Kit is a molecular biology reagent system produced by Thermo Fisher Scientific to convert total RNA into single-stranded cDNA. Its primary purpose is first-strand cDNA synthesis across a broad dynamic range prior to quantitative real-time PCR (qPCR) or endpoint PCR. In a two-step reverse transcription PCR workflow, this kit enables laboratories to synthesize and archive stable cDNA pools for multiple downstream amplifications.

What It Is

The Applied Biosystems High-Capacity cDNA Reverse Transcription Kit (also known as the high-capacity cDNA reverse transcription kit) provides the core enzymatic and buffer reagents required for reverse transcription. It delivers linear, proportional cDNA yields from diverse RNA inputs, supporting TaqMan probe and SYBR Green dye detection systems.

Who uses it: Molecular biologists, clinical laboratory technologists, genomics core facility operators, and life science procurement managers use this kit to standardize cDNA synthesis across research and diagnostic development workflows.

How It Works and Kit Components

The kit uses a recombinant retroviral enzyme primed with random oligonucleotides to transcribe RNA into cDNA without poly-A tail bias. The formulation contains five core components:

  • MultiScribe™ Reverse Transcriptase (50 U/µL): A recombinant Moloney Murine Leukemia Virus (M-MuLV) reverse transcriptase expressed in E. coli. It delivers high processivity with reduced RNase H activity to preserve RNA templates during polymerization.
  • 10X RT Random Primers: Synthetic random hexamers providing uniform priming across mRNA, non-coding RNA, and ribosomal RNA species without requiring a 3′ poly-A tail.
  • 25X dNTP Mix (100 mM total): An equimolar solution containing 25 mM each of dATP, dCTP, dGTP, and dTTP.
  • 10X RT Buffer: Optimizes reaction pH, ionic strength, and divalent magnesium ions (Mg2+) for enzyme kinetics.
  • RNase Inhibitor: Recombinant protein supplied in specific catalog versions to bind and inhibit neutral ribonucleases in a 1:1 ratio.

Types and Variants

The kit is supplied in four primary catalog configurations based on reaction volume and RNase inhibitor inclusion:

Catalog Number Reaction Capacity RNase Inhibitor Included Typical Laboratory Use Key Difference
4368814 200 reactions No Routine bench research with purified cell line RNA Standard reaction size; excludes RNase inhibitor
4368813 1,000 reactions No High-throughput screening and production genomics Bulk packaging; excludes RNase inhibitor
4374966 200 reactions Yes Primary tissues, biobanked samples, and biopsy specimens Includes recombinant RNase inhibitor vials
4374967 1,000 reactions Yes Large-scale translational research and clinical trials Bulk package supplied with RNase inhibitor

Sizes and Specifications

The kit delivers linear cDNA synthesis across five orders of magnitude. The table below outlines verified operational specifications from manufacturer user guides (Pub. No. MAN0017977 and Pub. No. 4375222):

Parameter Specified Value or Range Operational Role
Standard Reaction Volume 20 µL (scalable to 100 µL) Generates cDNA for multiple qPCR runs; scalable for banking
Input Total RNA Range 0.02 µg (20 ng) to 2.0 µg per 20 µL Linear dynamic range between RNA input and qPCR cycle threshold
Maximum RNA (Scaled) Up to 10.0 µg per 100 µL Enables high-yield conversion for low-abundance transcripts
MultiScribe Concentration 50 Units/µL Standard 20 µL reaction uses 1.0 µL (50 Units of enzyme)
dNTP Concentration 100 mM total (25 mM each dNTP) 25X stock delivers 4 mM total dNTPs in final 20 µL reaction
Kit Storage Temperature −25°C to −15°C Components must be kept in manual-defrost freezers
cDNA Storage Temperature −25°C to −15°C (short); −80°C (long) Ensures stability; repeated freeze-thaw cycles must be avoided

Standard 2X RT Master Mix Formulations

Reactions are assembled using a 2X Master Mix format (10 µL master mix plus 10 µL RNA sample diluted in nuclease-free water). Pipetting volumes differ based on RNase inhibitor inclusion:

Component With RNase Inhibitor (Cat. 4374966/4374967) Without RNase Inhibitor (Cat. 4368814/4368813)
10X RT Buffer 2.0 µL 2.0 µL
25X dNTP Mix (100 mM) 0.8 µL 0.8 µL
10X RT Random Primers 2.0 µL 2.0 µL
MultiScribe™ Reverse Transcriptase (50 U/µL) 1.0 µL 1.0 µL
RNase Inhibitor 1.0 µL 0.0 µL (omitted)
Nuclease-free H2O 3.2 µL 4.2 µL
Total 2X Master Mix Volume 10.0 µL 10.0 µL
RNA Template (up to 2 µg in water) 10.0 µL 10.0 µL
Total Reaction Volume 20.0 µL 20.0 µL

How to Choose Between Kit Configurations

Kit selection is determined by source RNA vulnerability, ribonuclease risk, and batch size:

  • RNase-Prone Tissues and Biobank Samples: When isolating RNA from tissues with high endogenous ribonuclease levels (pancreas, spleen, liver) or degraded specimens, select Cat. 4374966 (200 reactions) or 4374967 (1,000 reactions). The bundled inhibitor prevents degradation during room-temperature assembly and 25°C primer annealing.
  • Purified Cell Lines and Synthetic Transcripts: When processing high-integrity RNA (RIN ≥ 8.0) in ribonuclease-free conditions, the standard configuration (Cat. 4368814) provides equivalent cDNA yield at lower reagent cost.
  • Throughput and Logistics: Laboratories processing fewer than 50 samples weekly should choose 200-reaction sizes to avoid multiple freeze-thaw cycles. Automated platforms running 96-well or 384-well plates benefit from bulk 1,000-reaction units (Cat. 4368813 or 4374967).

Safe Use, Handling, and Quality Controls

Reliable cDNA synthesis requires strict temperature control, proper pipetting, and experimental controls matching standard molecular protocols.

Thermal Cycler Profile

Incubate reaction tubes or plates in a calibrated thermal cycler programmed with four discrete stages:

Stage Temperature Time Purpose
Stage 1 (Primer Annealing) 25°C 10 minutes Facilitates uniform annealing of random hexamers to RNA templates
Stage 2 (cDNA Synthesis) 37°C 120 minutes Optimal polymerization temperature for MultiScribe Reverse Transcriptase
Stage 3 (Enzyme Inactivation) 85°C 5 minutes Denatures reverse transcriptase to halt synthesis and prevent downstream PCR inhibition
Stage 4 (Hold) 4°C Indefinite hold Maintains sample stability prior to freezer storage or immediate PCR setup

Quality Controls and Downstream qPCR Limits

Adherence to the MIQE guidelines for qPCR reporting requires incorporating specific negative controls and dilution steps:

  • No-RT (RT−) Control: Assemble a control substituting nuclease-free water for MultiScribe enzyme. Amplification in subsequent qPCR reveals genomic DNA (gDNA) contamination in the template.
  • No-Template Control (NTC): Replaces template RNA with water to detect reagent contamination.
  • Downstream qPCR Volume Limit: Reverse transcription buffer salts, DTT, and glycerol can inhibit DNA polymerases during a standard PCR reaction setup. Limit unpurified cDNA template to ≤ 10% to 20% of the total qPCR reaction volume (e.g., ≤ 2 µL cDNA in a 20 µL reaction).

Common Mistakes to Avoid

Avoiding these common errors preserves reaction linearity and data fidelity:

  • Overloading Input RNA (> 2 µg): Adding more than 2 µg of RNA to a 20 µL reaction saturates dNTPs and enzyme active sites, creating a plateau in cDNA yield and disrupting quantification linearity. Scale reaction volumes proportionally for larger inputs.
  • Omitting the 25°C Annealing Hold: Heating directly to 37°C without the initial 10-minute hold at 25°C causes premature primer dissociation, leading to truncated or biased cDNA products.
  • Automatic Defrost Freezers: Storing MultiScribe enzyme in frost-free freezers causes repeated warming cycles that deactivate the polymerase. Use manual-defrost units at −25°C to −15°C.
  • Overlooking gDNA in qualitative RT-PCR assays: Because random primers transcribe both RNA and carryover DNA, always verify RNA purity with an RT− control or perform DNase I digestion prior to reverse transcription.

Frequently Asked Questions

Can I substitute oligo(dT) primers into this kit?

The kit is formulated and validated specifically with 10X RT Random Primers. Substituting oligo(dT) primers requires re-optimizing annealing temperatures and reaction kinetics, which falls outside manufacturer validation specifications.

How should synthesized cDNA be stored and diluted before qPCR?

Store synthesized cDNA at −25°C to −15°C for short-term use or −80°C for long-term archiving. For high-abundance transcripts, diluting cDNA 1:5 or 1:10 with nuclease-free water or 10 mM Tris buffer (pH 8.0) reduces RT buffer carryover into downstream qPCR.

How does this kit compare to one-step RT-qPCR systems?

This kit is intended for two-step workflows where reverse transcription and PCR amplification are decoupled. Two-step protocols allow cDNA archiving and multiple target queries from a single RT batch, whereas one-step systems combine reagents in one tube for rapid screening without archiving cDNA.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Applied Biosystems High-Capacity cDNA Reverse Transcription Kit: Components, Protocol, and qPCR Guidelines

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →