Written and maintained by CASRAI Editorial Board
Published
On this page
Ar-Ar dating, written 40Ar/39Ar dating, is a radiometric method that dates potassium-bearing minerals by measuring the ratio of radiogenic argon-40 to argon-39 in a single gas sample. The argon-39 is made on purpose by irradiating the sample with fast neutrons in a nuclear reactor, so it stands in for potassium and the lab only has to measure isotope ratios, never an absolute potassium amount.
Short answer: what Ar-Ar dating measures
Natural potassium contains 40K, which has a half-life of 1.25 billion years. A small fraction of 40K atoms decay to 40Ar, a noble gas that accumulates in potassium-bearing minerals over time. The New Mexico Geochronology Research Laboratory (NMGRL) puts the share at about 11 percent, with the remainder becoming 40Ca; the Freiberg Ar-Ar laboratory gives 10.5 percent and 89.5 percent. Because 40Ca is not an argon isotope, only the 40Ar branch leaves a measurable trace.
Ar-Ar dating is a variation of the older K/Ar method. In K/Ar, a lab measures potassium and 40Ar on separate aliquots and needs absolute amounts of both. In Ar-Ar, neutron bombardment converts a known fraction of the sample’s 39K into 39Ar through a fast-neutron reaction, so one measurement series on one gas fraction yields the 40Ar/39Ar ratio. The USGS TRIGA Reactor facility describes the 39Ar as a proxy for potassium and says the technique spans ages from about 2,000 years to the age of the Solar System, 4.5 billion years, on samples from a single grain to a few millimetres.
Definition and scope
NMGRL describes the method as a K/Ar variation that uses 39ArK, the argon-39 produced from potassium during irradiation, in place of a separate potassium measurement. The Freiberg Ar-Ar laboratory calls it a modified K-Ar technique and lists K-feldspar, micas and hornblende as suitable K-rich minerals. NMGRL adds that total-fusion work suits very argon-retentive minerals such as sanidine.
The scope is therefore narrow and practical: a K-bearing mineral or rock, a reactor that can irradiate it, an ultra-high-vacuum extraction line, and a gas-source mass spectrometer. This page covers the laboratory workflow and how a lab reads the output; it does not cover geological interpretation of any particular rock suite. For the instrument side, see the guide to what a mass spectrometer is.
How Ar-Ar dating works in the laboratory
The workflow moves through five stages. Each one introduces a correction or a source of uncertainty that the final age depends on.
- Preparation and packaging. The unknown samples are loaded with a mineral monitor of known age. NMGRL irradiates in machined aluminium disks and alternates standards and unknowns in every other position.
- Irradiation. The package goes into a reactor core. The Freiberg laboratory quotes a neutron flux of roughly 1012 neutrons per cm2 per second. Irradiation cannot be done at the bench: it needs access to a reactor, which is why facilities such as the USGS TRIGA Reactor publish neutron irradiation for argon isotopic dating as a dedicated capability.
- Extraction. Argon is released under ultra-high vacuum, by an infrared laser or by a furnace according to Freiberg, then cleaned of other gases.
- Measurement. A sector-field or other gas-source mass spectrometer measures the argon isotope ratios.
- Calculation. The lab corrects for atmospheric argon and for reactor-produced interferences, derives the neutron-flux parameter J from the monitor, and calculates an apparent age for each gas fraction.
The monitor and the J parameter
NMGRL explains that a mineral standard, or monitor, of known age is irradiated together with the samples. The neutron-flux parameter, J, is extrapolated from the monitor positions to the unknown positions. NMGRL reduces the uncertainty in J by constraining the geometry of the irradiation package and by analysing more monitor aliquots per standard location. In practice this means the age of every unknown carries the uncertainty of the monitor measurements around it, which is why the packaging layout is recorded as part of the lab’s data.
The traditional primary standard is the hornblende MMhb-1 from the McClure Mountains, Colorado. NMGRL notes that labs have found its K/Ar age hard to agree on and not always reproducible because the material is heterogeneous, so secondary standards such as sanidine are dated relative to it. NMGRL also names U/Pb and the astronomical polarity time scale as independent ways to test standard ages. This is a reference-material problem familiar from other fields; the broader standard reference material guide explains how certified materials are used to anchor measurements.
Interference corrections
Neutron bombardment does not only make 39Ar from 39K. It also makes argon from calcium, chlorine and potassium through other reactions, and these products add to the signal of the isotopes the analyst cares about. NMGRL corrects for them by irradiating pure salts and glasses alongside the samples and measuring the argon they release. The table below sets out the correction materials and the values NMGRL says they supply.
| Irradiated material | What it supplies | What the lab uses it for |
|---|---|---|
| K-rich glass | Reactor-produced 40Ar from potassium (the 40Ar/39Ar production ratio from K) | Subtracting 40Ar that the reactor, not radioactive decay, added |
| CaF salt | 36Ar/37Ar and 39Ar/37Ar production ratios, plus a K/Ca estimate | Subtracting calcium-derived 36Ar and 39Ar; estimating the K/Ca of the sample |
| KCl salt | 38Ar/39Ar production ratio | Estimating the K/Cl ratio of the sample |
NMGRL also corrects for atmospheric argon using a constant 40Ar/36Ar value of 295.5. The reaction 40Ca to 37Ar flags calcium and 37Cl to 38Ar flags chlorine, which is how the lab reads K/Ca and K/Cl from the same run that produces the age.
Extraction methods and what each one produces
How the argon is released determines what the lab can say about a sample. NMGRL describes four common routes, summarised in the data table below on this page. Step heating, by furnace or laser, is the most common and is shown as an age spectrum or an isochron. Mechanical crushing releases argon from a single sample in multiple steps. A laser probe with a spot of 100 microns or less can give several ages on one grain, and the results can be drawn as a map of lateral argon distribution. Total fusion releases all the argon at once and suits very retentive minerals such as sanidine, with results shown as probability distribution diagrams or ideograms.
Reading age spectra, plateaus and isochrons
A step-heating run produces one apparent age per heating step, plotted against the cumulative fraction of 39ArK released. NMGRL’s data tables list, for each step, the isotope ratios, 39ArK release, K/Ca, radiogenic yield, age and 1σ error. A flat portion of that spectrum is the plateau.
Plateau definitions differ between labs
The classic definition, from Fleck and colleagues (1977), is three or more contiguous heating steps comprising 50 percent or more of the 39ArK released and overlapping at the two-sigma confidence level. NMGRL says it no longer relies on that definition and instead tests the statistical precision of a number of contiguous steps using the criteria of Mahon (1996). Its data-table notes say a plateau must comprise at least two contiguous steps and that plateau ages are weighted by the inverse of the variance. For anyone comparing published ages, this matters: two papers can both report a plateau age and have used different tests to decide which steps belonged to it.
The isochron as a check on trapped argon
An isochron tests the assumption that trapped argon has the composition of modern air. NMGRL explains that the best-fit line through the data yields the trapped 40Ar/36Ar value from the y-intercept and the age from the x-intercept, and that goodness of fit is judged by MSWD, with values below 2.5 commonly accepted. This is the main internal check Ar-Ar has that K/Ar lacks. NMGRL’s methods page says K/Ar offers no reliable way to test its own assumptions of a closed system and no non-atmospheric argon: argon loss gives ages that are too young, and excess argon gives ages that are too old.
NMGRL also reports a total-gas age, the weighted mean of all steps, which it describes as analogous to a conventional K/Ar age.
Where it matters for labs and data management
Ar-Ar ages are only as reproducible as the records behind them. From the sources above, the items a lab needs to keep alongside every age are: the monitor mineral and its assumed age, the layout of samples and monitors in the irradiation package, the J values and their uncertainty, the interference correction factors from the K-glass, CaF and KCl irradiations, the atmospheric ratio used, and the plateau test applied. Without the monitor age and the decay constants, an age cannot be recalculated when a standard is revised. NMGRL states that uncertainty in the 40K decay constants limits both precision and accuracy because the decay is branched and the half-life is long. A lab that records the constants it used can restate its ages when those values change; a lab that does not cannot.
For calibration practice in general, including how reference measurements are scheduled and documented, see what calibration is. For stratigraphic context that ages are often interpreted against, see the Macrostrat guide.
Ar-Ar compared with K/Ar
The two methods share the same decay system but differ in what they must measure and in how well they can police their own assumptions. NMGRL states that K/Ar requires absolute measurements of both potassium and 40Ar, with a 38Ar spike used to determine radiogenic 40Ar. Ar-Ar measures ratios only, which NMGRL says improves precision and allows smaller samples. The trade-off is the irradiation step, which adds a reactor, a monitor, the J parameter and the interference corrections described above.
Common misunderstandings
- “Ar-Ar dates organic material.” It does not. The method dates K-bearing minerals and rocks through the 40K to 40Ar decay.
- “Ar-Ar needs no potassium.” It still depends on potassium: 39Ar is produced from 39K and acts as the proxy. What disappears is the separate absolute potassium measurement.
- “A plateau always means a reliable age.” A plateau is a statistical statement under a chosen definition. NMGRL moved away from the Fleck criteria for this reason, and recoil and redistribution can still affect the spectrum.
- “The age is fixed once measured.” Standard ages and decay constants have uncertainty, and ages depend on the monitor age chosen.
Limits to keep in view
NMGRL lists three limitations of the method. First, 39ArK can be lost by recoil during the neutron reaction, which produces anomalously old ages; this becomes significant mainly in very fine-grained materials such as clays and glass. Second, in multiphase samples such as basaltic whole rocks, 39Ar can move between mineral phases and change the shape of the age spectrum. Third, the uncertainty in the 40K decay constants limits precision and accuracy.
The USGS TRIGA Reactor facility reports analytical errors commonly less than 0.25 percent absolute. That figure describes analytical precision, not the combined uncertainty of monitor age and decay constants, so ages should be quoted with the lab’s own stated uncertainty.
Sources
- New Mexico Geochronology Research Laboratory: K-Ar and 40Ar/39Ar methods, checked 2026-11-18
- New Mexico Geochronology Research Laboratory: Data presentation and age spectra, checked 2026-11-18
- U.S. Geological Survey: Neutron irradiations for argon isotopic dating, USGS TRIGA Reactor, checked 2026-11-18
- TU Bergakademie Freiberg Ar-Ar laboratory: Ar-Ar dating principles, checked 2026-11-18
Data: Ar-Ar argon extraction methods and the results they produce
Compares the four argon extraction routes used in 40Ar/39Ar dating by how the gas is released, what kind of sample or question each suits, and how the results are displayed. Compiled from the New Mexico Geochronology Research Laboratory methods page, with the heating device from the TU Freiberg Ar-Ar laboratory.
| Extraction method | How argon is released | Suited to | How results are shown |
|---|---|---|---|
| Step heating | Gas released in successive temperature steps by furnace or laser | The most common approach; tests whether ages are consistent across steps | Age spectrum or isochron |
| Mechanical crushing | Argon released from a single sample in multiple steps by crushing | Single samples released step-wise by breaking them rather than heating | Step-wise release from one sample |
| Laser probe | Focused laser spot of 100 microns or less | Obtaining multiple ages on a single grain | Ages per spot, or a map of lateral argon distribution |
| Total fusion | All argon released at once by laser | Very argon-retentive minerals such as sanidine | Probability distribution diagram or ideogram |
Sources
- NMGRL: K-Ar and 40Ar/39Ar methods (accessed 2026-11-18)
- TU Bergakademie Freiberg Ar-Ar laboratory: principles (accessed 2026-11-18)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







