Skip to main content
v2026.11,986 entries · CC-BY 4.0

Array CGH (aCGH): How It Works, Resolution and Limits

Array CGH measures DNA copy number across the genome. What it detects, its resolution against karyotype, and the blind spots that decide which assay to use.

Written and maintained by CASRAI Editorial Board

Published

On this page

Array CGH (array comparative genomic hybridization, aCGH) is a microarray method that measures DNA copy number across the whole genome. A patient DNA sample and a reference DNA sample are labelled with different dyes and compete for the same probes on an array, so a stretch of DNA that is lost or gained in the patient shows up as a shift in the dye ratio. It finds deletions and duplications; it is not a sequencing test.

Short answer: what array CGH does and does not do

Array CGH reports gains and losses of DNA, called copy number variation, at a resolution far finer than a chromosome banding test. The NHS England Genomics Education Programme describes resolution of about 50 to 200 kb depending on probe coverage, against about 5 Mb for karyotyping (GeNotes: Microarray (array CGH)). It cannot detect balanced rearrangements such as balanced translocations or inversions, it gives no sequence-level information, and it can miss low-level mosaicism. Those blind spots decide which assay a lab or clinical team should reach for.

Definition and scope

Comparative genomic hybridization was first described for chromosome spreads. In the 1992 Science paper by Kallioniemi and colleagues, differentially labelled test DNA and normal reference DNA were hybridized together to normal chromosome spreads, and regions of gain or loss, including deletions, duplications and amplifications, appeared as changes in the ratio of the two fluorochromes along the chromosomes (Kallioniemi et al., Science 1992, PMID 1359641). Array CGH keeps the same two-dye logic but replaces the chromosome spread with an array of defined DNA probes fixed to a slide or chip. Pinkel and Albertson reviewed the array format for measuring DNA copy-number variation and its use in cancer, noting that copy-number alterations occur in normal individuals, in development and in cancer (Pinkel and Albertson, Nature Genetics 2005, PMID 15920524).

The same technique appears in the literature under several names. Array comparative genomic hybridization, comparative genomic hybridization array and comparative genomic hybridization arrays all refer to the array-based method described here. The older chromosome-based method is simply called CGH or conventional CGH. Array CGH belongs to the wider family of chromosomal microarray (CMA) tests, which also includes SNP arrays; the probe layout, not the underlying idea of reading copy number from hybridization signal, is what differs.

Array comparative genomic hybridization versus a general DNA microarray

A gene-expression microarray measures how much RNA a sample contains for each gene. Array CGH uses a similar slide format but measures DNA dosage, so the question it answers is how many copies of a region are present, not how active a gene is. The general principles of probe hybridization and signal readout are covered in the guide to DNA microarray analysis, and the idea of a probe that binds a complementary target is explained in what a hybridization probe is.

How array CGH works in practice

The GeNotes description gives the core design. Patient DNA and reference DNA are each labelled with a different dye and are applied to an array of oligonucleotide probes, where the two samples compete to bind each probe. Because the dyes are different, the scanner can measure how much of each sample bound at every probe position. The signal is then read as follows.

Signal colour What it indicates
Red Deletion in the patient sample relative to the reference
Green Duplication in the patient sample relative to the reference
Yellow Equal amounts of patient and reference DNA at that probe (no copy number change)

This colour convention is the one used in the GeNotes description of aCGH; software settings and dye assignments can differ between platforms, so the colour key of the platform in use governs how a plot is read. The key operational point is that array CGH compares two samples against each other. The reference sets the baseline, so the result is a relative ratio rather than an absolute count.

Because the method reads DNA signal at fixed probe positions, it is a mapping tool and not a sequencer. It tells you that a segment of the genome is present in too few or too many copies, and roughly where its boundaries fall as defined by the probes, but not what the bases inside it are.

Probe types

GeNotes lists the probe designs used on microarrays for copy number analysis. The distinction matters because probe design sets what an array can report.

Probe type What the source says about it
Oligonucleotide Gives even coverage of the genome backbone and can be designed to target regions linked to known syndromes
SNP Allele-specific probes at single-nucleotide polymorphism sites; allows detection of copy-neutral loss of heterozygosity, some uniparental disomy and ploidy changes
Hybrid Arrays combining the two designs

SNP arrays and aCGH compared

GeNotes distinguishes the two array formats clearly. On an SNP array, a deletion appears as homozygous SNPs with lower signal, while a duplication appears as a shifted allele ratio with higher signal. Because SNP probes carry genotype information, SNP arrays can also detect copy-neutral loss of heterozygosity, some uniparental disomy and changes in ploidy. A two-dye aCGH design cannot detect triploidy, uniparental disomy or copy-neutral loss of heterozygosity. GeNotes also notes that the NHS Genomic Medicine Service uses SNP arrays, a reminder that a service’s choice of platform reflects exactly these trade-offs.

The data table on this page sets array CGH, SNP arrays, G-banded karyotype and MLPA side by side, using only the statements in the sources listed below. Three points from it are worth stating in words.

  • Resolution. Arrays resolve about 50 to 200 kb depending on coverage, whereas karyotyping resolves about 5 Mb (GeNotes). That gap is why arrays find submicroscopic deletions and duplications that a banding test cannot see.
  • Balanced rearrangements. Arrays do not detect balanced translocations or inversions because no DNA is gained or lost; GeNotes points to karyotyping for these.
  • Small changes in a known gene. Small intragenic exon deletions or duplications may be missed by an array. For a known gene, GeNotes points to MLPA instead.

Array CGH also gives no positional information about where an extra copy sits. For example, it cannot show whether duplicated material lies in tandem with the original copy. Mosaicism, where only a proportion of cells carry the change, may not be reliably detected.

Diagnostic yield: why arrays displaced karyotype as a first test

The International Standard Cytogenomic Array (ISCA) Consortium analysis by Miller and colleagues drew on two workshops and 33 studies covering 21,698 patients tested by chromosomal microarray. It reported a diagnostic yield of 15% to 20% for microarray against about 3% for G-banded karyotype, excluding Down syndrome and other recognizable chromosomal syndromes, and attributed the difference to submicroscopic deletions and duplications. The consortium recommended chromosomal microarray in place of G-banded karyotype as the first-tier test for individuals with developmental delay or intellectual disability, autism spectrum disorders or multiple congenital anomalies (Miller et al., American Journal of Human Genetics 2010, PMID 20466091).

The same paper is explicit about the limits. Truly balanced rearrangements and low-level mosaicism are generally not detectable by arrays, though the authors describe them as relatively infrequent (under 1%) in this patient population. They advised that karyotype remains appropriate for obvious chromosomal syndromes, a family history of chromosomal rearrangement and multiple miscarriages.

The GeNotes page lists the clinical indications for microarray in similar terms: developmental delay, intellectual disability, autism, epilepsy and congenital abnormalities, and in prenatal care for ultrasound anomalies as a second-line test after a negative QF-PCR. These are statements about how the test is used in clinical genetics services; this page does not give advice on testing any individual.

Where it matters for labs, clinics and supply decisions

For a laboratory manager or research group, the practical consequence of the sources is a question of fit rather than of equipment. The questions below follow directly from the sourced limits and are an editorial checklist, not a protocol.

  1. Is the target a copy number change? If the question is about deletions, duplications or amplification across the genome, array CGH or an SNP array fits. If the question is about sequence changes, it does not, because the method is not a sequencing test.
  2. Could the change be balanced? If a balanced translocation or inversion is suspected, an array cannot show it and karyotyping is the cited alternative.
  3. Is copy-neutral loss of heterozygosity, uniparental disomy or a ploidy change in scope? A two-dye aCGH design cannot report these, while SNP arrays can report copy-neutral loss of heterozygosity, some uniparental disomy and ploidy changes.
  4. Is the target a small change in one known gene? Small intragenic exon deletions or duplications may be missed on an array, and GeNotes points to MLPA.
  5. Could the sample be mosaic? Both GeNotes and Miller et al. flag that low-level mosaicism may not be reliably detected, so a negative array does not exclude it.

In research settings the same logic carries over to cell lines and tumour samples. Pinkel and Albertson’s review frames array CGH as a way to measure copy-number alterations in cancer genomes, and the original CGH paper reported 16 regions of amplification in bladder tumour samples and cell lines. When a project needs to confirm a copy number finding at the chromosome level, in situ hybridization methods are the related technique; see in situ hybridization and the FISH method. Array CGH is also related in spirit to ChIP-on-chip, which uses the same array readout for a different question (protein-DNA binding rather than DNA dosage), and the underlying concept is explained in copy number of a gene.

Common misunderstandings

Array CGH is not sequencing

It reports dosage at probe positions. GeNotes states directly that it is not a sequencing test, so point mutations and small sequence changes inside a copied segment are outside its reach.

A normal array does not mean a normal genome

Balanced rearrangements, low-level mosaicism and (for aCGH) copy-neutral changes sit outside what the assay reports. A normal result means no detectable copy number change at the resolution of that array.

Resolution is not a single number

The figure of 50 to 200 kb is a range that depends on probe coverage,. A target region covered by few probes is resolved less finely than one with dense coverage, which is one reason syndrome-targeted oligonucleotide designs exist.

aCGH and SNP arrays are not interchangeable

Both detect deletions and duplications, but only SNP-based designs add genotype information. If loss of heterozygosity or uniparental disomy matters to the question, the platform choice changes what can be seen.

Array CGH has not replaced every older test

Miller et al. recommend microarray as a first-tier test for specific indications, while retaining karyotype for others. The two tests answer different questions.

Sources

Data: What array CGH, SNP arrays, karyotype and MLPA can and cannot detect

Side-by-side summary of four genomic assays, compiled from the NHS England Genomics Education Programme GeNotes page on microarray (array CGH) and the ISCA Consortium consensus paper (Miller et al. 2010). Cells record only what those sources state; 'Not stated' marks cells the sources do not cover.

What array CGH, SNP arrays, karyotype and MLPA can and cannot detect
MethodMain targetResolutionBalanced translocations or inversionsCopy-neutral LOH, UPD or ploidy change
Array CGH (two-dye oligonucleotide array)Copy number gains and losses; not a sequencing testAbout 50-200 kb depending on coverageNot detected; karyotype is used insteadCannot detect triploidy, UPD or copy-neutral LOH
SNP arrayCopy number gains and losses plus allele informationAbout 50-200 kb depending on coverageNot detected; karyotype is used insteadCan detect copy-neutral LOH, some UPD and ploidy changes
G-banded karyotypeChromosome-level structural and numerical changesAbout 5 MbUsed where balanced rearrangements are suspectedNot stated
MLPASmall intragenic exon deletions or duplications in a known geneNot statedNot statedNot stated

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Array CGH (aCGH): How It Works, Resolution and Limits

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →