Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
General product and regulatory information only, drawn from FDA records and the FDA 510(k) summaries named below. It is not medical advice and does not replace guidance from a clinician or the manufacturer’s Instructions for Use.
An at-home insemination kit, as FDA classifies it, is a set of single-use plastic syringes and semen collection cups supplied with Instructions for Use. In FDA’s classification database the device is called an “At Home Intravaginal Insemination System” (product code QYZ), a Class II device regulated under 21 CFR 884.6110. This page is a contents checklist built from two FDA 510(k) summaries, so you can see what a cleared kit contains and what the regulatory testing behind it covers.
Purpose and setting
This page is for anyone comparing kit listings who wants to know what the regulatory record says a kit consists of, and what “FDA-cleared” does and does not tell them.
FDA’s classification record for product code QYZ gives the device’s definition as: “To deliver semen to the vaginal canal for insemination.” The 510(k) summary for the Mosie Baby Kit (K231203, cleared November 29, 2023) states the indication as over-the-counter home use, by individuals who have been unable to conceive through intercourse or choose not to conceive through intercourse, for semen collection and the delivery of semen or donor sperm to the vaginal canal. The summary for the PherDal At-Home Insemination Kit (K231645, letter dated December 14, 2023) states the same over-the-counter indication.
The kit holds a collection cup and a syringe. In the K231203 summary the cup holds the semen and the syringe withdraws it from the cup. How and when to use a kit is set out in each kit’s Instructions for Use and is a question for a clinician, so this page does not describe use.
Checklist table
The rows below come directly from the two 510(k) summaries FDA published. They are a record of what these two cleared kits contain, not a list of what every kit on the market contains.
| Item | Quantity in the cleared kit | Why it is in the kit | Notes from the 510(k) summary |
|---|---|---|---|
| Insemination syringe | K231203: two. K231645: three sets of syringe and cup. | Delivers semen to the vaginal canal and, in K231203, withdraws it from the collection cup. | K231203: rounded front end with a slotted tip opening, rounded stopper, flanges for handling; polycarbonate, silicone and ABS. K231645: syringe body polystyrene, plunger a polycarbonate / ABS blend / thermoplastic elastomer as listed in the summary. |
| Semen collection cup | K231203: two. K231645: three (one per set). | Holds the semen sample. | Polystyrene in both summaries. |
| Instructions for Use | One | Carries the labeling that FDA reviewed, including sample storage and disposal. | In K231203 the labeling questions were each answered correctly by at least 90% of study participants. |
Neither summary lists a needle. Both describe a plastic syringe with a rounded tip, which is the meaning of “insemination syringe” in this device class.
The older conception-assist kit record
FDA also keeps a separate classification record, product code OBB, “Kit, Conception-Assist, Home Use” (Class II, 21 CFR 884.5250). It describes a different and older type of product: a kit used at home following physician instruction, listing cervical caps, polyurethane condoms, ovulation predictors, pregnancy tests, moisturizer samples, a journal, an instruction manual, conception wheels and a medical provider envelope. It is a classification record only; it should not be read as the contents of an over-the-counter QYZ kit.
What varies by kit type
- Sterile or non-sterile. The K231203 summary says each component is single-use only and supplied non-sterile. The K231645 summary describes sterile, single-use syringes and cups, sterilized by gamma irradiation (ISO 11137-1:2006 and ISO 11137-2:2013) to a sterility assurance level of 10-6.
- Number of sets. Two syringe and cup pairs in K231203; three sets in K231645.
- Materials. The two summaries list different plastics for the syringe, as the table shows.
- Prescription predicate. The predicate named in both summaries (Shepard Intrauterine Insemination Set / Insemi-Cath, K172321) is a prescription, sterile, intrauterine device. The over-the-counter kits are indicated for delivery to the vaginal canal.
A clearance covers the specific device in its summary. A listing that says “FDA-cleared” does not tell you which of these variations the product has; the Instructions for Use and the 510(k) summary do.
Storage, expiry and restocking
- Single use. Both summaries describe the components as single-use. Used components are not restocked or reused.
- Shelf life. Both summaries support shelf life by accelerated aging under ASTM F1980-21. The K231645 summary gives a five-year shelf life for the sterile kit and tests the sterile-barrier seal under ASTM F88/F88M-15. Dates and storage conditions for a particular product are printed on its own packaging and Instructions for Use.
- Sample storage and disposal. K231203 notes that the labeling covers sample storage and disposal; the Instructions for Use is the source for those details.
For the general method behind such claims, see the CASRAI guide to shelf life and packaging validation for medical devices.
Standards and rules that apply
| Rule or standard | What the record says |
|---|---|
| 21 CFR 884.6110, assisted reproduction catheters (Class II) | The regulation under which QYZ devices fall. Special controls listed include mouse embryo assay information, endotoxin testing, sterilization validation, design specifications, labeling requirements, biocompatibility testing and clinical testing. |
| ISO 7886-1:2017 | K231203 syringe functional tests were based on it: barrel dimensions, flanges, plunger stopper, leakage past the stopper, force to operate the piston and fit. |
| USP <61>, <62> and <1111> | K231203 bioburden limits: total aerobic microbial count below 102 cfu/g, total yeast and mould count below 101 cfu/g, and absence of Pseudomonas aeruginosa, Staphylococcus aureus and Candida albicans. |
| ISO 10993 series | Cytotoxicity (ISO 10993-5:2009), sensitization (ISO 10993-10:2010) and vaginal irritation (ISO 10993-23:2021); the K231203 results were non-cytotoxic, non-irritating and non-sensitizing. See FDA guidance on biocompatibility. |
| Human Sperm Survival Assay | Both summaries use an acceptance criterion of 80% of control motility at 24 hours. |
| ASTM F1980-21 | Accelerated aging for shelf life (both summaries). |
These devices reached the market through the 510(k) pathway; see FDA 510(k) premarket notification and predicate devices and substantial equivalence. For the broader category, see what is a medical device and what is a syringe.
The labeling studies are part of the record too: K231203 reports a self-selection study with 32 participants and a human-factors validation with 30 participants, half self-administered and half administered to a recipient.
FAQ
What is an insemination syringe?
In the two FDA 510(k) summaries cited here, it is a single-use plastic syringe with no needle, a rounded front end with a slotted tip opening, a rounded stopper and flanges for handling, supplied with a semen collection cup.
Is an at-home insemination kit FDA-cleared?
Some are. FDA lists product code QYZ, and the summaries for K231203 (cleared November 29, 2023) and K231645 (letter dated December 14, 2023) are the two this page uses. Clearance applies to the specific device named in a summary, so check the product against its 510(k) number.
What does QYZ mean?
QYZ is FDA’s product code for the “At Home Intravaginal Insemination System”, regulated under 21 CFR 884.6110 as a Class II device.
Are the kits sterile?
It depends on the kit. The K231203 components are supplied non-sterile; the K231645 kit is gamma-sterilized.
Sources
All sources checked 2026-10-30.
- openFDA device classification, product code QYZ: https://api.fda.gov/device/classification.json?search=product_code:QYZ
- openFDA device classification, product code OBB: https://api.fda.gov/device/classification.json?search=product_code:OBB
- 21 CFR 884.6110, Assisted reproduction catheters, Legal Information Institute: https://www.law.cornell.edu/cfr/text/21/884.6110
- FDA 510(k) summary K231203 (Mosie Baby Kit): https://www.accessdata.fda.gov/cdrh_docs/pdf23/K231203.pdf
- FDA 510(k) summary K231645 (PherDal At-Home Insemination Kit): https://www.accessdata.fda.gov/cdrh_docs/pdf23/K231645.pdf







