Written and maintained by CASRAI Editorial Board
Published
On this page
BindingDB is a public, web-accessible database of measured binding affinities between small, drug-like molecules and protein drug targets, hosted by SSPPS at UC San Diego. On its own information page it reports about 3.2 million binding data, over 1.4 million compounds and about 11,500 protein targets, extracted from literature, patents, PubChem and ChEMBL.
Definition and scope
BindingDB stores experimental measurements, not predictions. Each record ties a compound to a target and to a measured affinity value such as an IC50, Ki, Kd or EC50. The site describes its data as coming from several measurement techniques: enzyme inhibition and kinetics, isothermal titration calorimetry (ITC), NMR, and radioligand and competition assays. The focus is interactions between proteins considered drug targets and small molecules that resemble drugs, with a small additional set of host-guest data.
The database sits in the medicinal chemistry and drug discovery toolchain next to compound resources such as ChEMBL and PubChem, drug-centred resources such as DrugBank, and structure and sequence resources such as the Protein Data Bank and UniProt. Its distinguishing feature is that affinities are the organising unit of the data.
BindingDB’s 2025 database paper (Liu et al., Nucleic Acids Research 53:D1633-D1644) describes it as a FAIR knowledgebase of protein-small molecule binding data and notes that it is listed in FAIRsharing. For how those principles are defined, see the FAIR Data Principles entry.
What BindingDB contains
The information page gives three headline counts that grow with each release: about 3,246,374 binding data, 11,519 targets and more than 1,447,830 compounds. A smaller part is curated by BindingDB staff: about 1.6 million data for 780,000 compounds and 4,800 targets. The remainder is imported from other resources. The paper’s mid-2024 snapshot was about 2.9 million measurements for 1.3 million compounds, which shows the growth between the paper and the current site.
Where the data come from
The site lists four origins: data extracted by the BindingDB project from the literature and from patents; selected PubChem confirmatory BioAssays; ChEMBL entries whose target type is a protein; and a small host-guest set. According to the paper, about half of the measurements were extracted by BindingDB staff from US patents and journal articles, and most of the rest were imported from ChEMBL. Data extracted by BindingDB staff typically carry more detail about experimental conditions than imported records, as the information page states.
Affinity types
The paper breaks the 2024 holdings down by measurement type: roughly 1.8 million IC50 values, about 560,000 Ki values, about 220,000 EC50 values and about 100,000 Kd values. For all of these, a smaller number means a stronger interaction. The REST API accepts IC50, Ki and Kd as its affinity types.
How the data are curated
Curation is a screening-and-extraction process. According to the 2025 paper, US patents are screened weekly from the USPTO redbook by Cooperative Patent Classification class (C07 and A61), by chemical structures and by keywords such as IC50 and Kd. A first curator pass extracts the data and a second check follows. Patents are data-rich: they average about 160 data points each against about 40 for an article. Over the last two years covered by the paper, 1,443 US patents yielded 241,430 data points, and 2,644 ChEMBL articles yielded 101,170.
One rule change matters for anyone building datasets: since mid-2024, BindingDB rejects data reported only as bins or thresholds (for example, IC50 below 1 μM), because a threshold is not a measured value.
Structures and sequences
BindingDB links to the Protein Data Bank rather than curating 3D structures itself. The paper reports 15,328 PDB structures matched to BindingDB targets at more than 85% sequence identity, of which 10,126 match at 100% identity. It also states that BindingDB does not collect PDBbind data because that resource’s licence restricts redistribution.
Downloads and web services
The download page says files are updated usually monthly, and the data table below lists the main files with the sizes shown on the page. Beyond these, the page offers subsets by origin or measurement type (BindingDB articles, ChEMBL, Patents, PubChem, PDSP Ki, CSAR, Covid-19, ITC and host-guest ITC), FASTA files of target sequences, identifier maps to PubChem CID and SID, ChEBI, DrugBank, UniProt and PubMed, md5 checksums, and KNIME workflows. An Oracle dump is marked discontinued.
Which file to use
- Main TSV. The all-data TSV leaves out assay descriptions, which the page calls bulky and repetitive; they are supplied in a separate Assays archive.
- Terse files. A file marked terse lists each compound once, with its multiple targets.
- SDF files. Use the 2D SDF for structure records with data, and the 3D SDF when three-dimensional coordinates are needed. The 3D file is the largest in the table.
- Subsets. The origin-based subsets let a project use only, for example, patent-derived or ChEMBL-derived records.
Archive and API
A quarterly archive is kept at UC San Diego Library (library.ucsd.edu/dc/collection/bb03870458), and the paper adds that the archive is also held through Chronopolis. The RESTful API uses GET requests, returns XML by default and JSON when the response parameter is set to application/json, and returns an empty string when nothing matches. Its documented operations are getLigandsByPDBs (PDB identifiers, a cutoff in nM and an identity percentage), getLigandsByUniprots and getLigandsByUniprot (UniProt identifiers and a cutoff), and getTargetByCompound (a SMILES string and a similarity cutoff).
Licences and citation
The information page states two licences: data imported from ChEMBL are provided under Creative Commons Attribution-Share Alike 3.0 Unported, and data curated by BindingDB staff are provided under Creative Commons Attribution 3.0. The 2025 paper describes the curated data as CC BY 4.0, so a project that must cite the licence precisely should quote the statement it relied on and the date. The download page itself states no licence. The recommended citation is the 2025 paper: Liu T et al., Nucleic Acids Research 53:D1633-D1644.
Where it matters for labs and drug discovery teams
The paper reports a 2020 user survey in which 15% of respondents used BindingDB for machine learning or AI work. For that use the practical points are the ones the curators themselves raise.
- Unit and target errors. The paper identifies a 1000-fold unit error (nM entered as μM, or the reverse) as the most common curation error, followed by misidentified targets. It says fewer than 10 user error reports arrive per year.
- Patent versus article values. Patent-derived IC50, Ki and Kd values are, by the most common value, about ten times lower (stronger) than article values, and patent compounds are larger than article compounds. A project that pools the two origins should record which origin each value came from, because the distributions differ.
- Coverage. The collection is weighted toward US patents; WIPO patents are selectively covered.
Checklist before reusing BindingDB data
The checks below follow from the limits the curators and the download page describe; they are a working aid, not a BindingDB requirement.
- Record the release. Files are updated usually monthly and a quarterly archive exists, so note the file name and download date for reproducibility.
- Choose the affinity type deliberately. IC50, Ki, Kd and EC50 are different measurements; the API itself exposes only IC50, Ki and Kd.
- Check units. The most common curation error is a 1000-fold unit mistake, so screen values that are implausible for their target class.
- Separate the origin. Keep patent, article, ChEMBL and PubChem records distinguishable, since patent values run about tenfold stronger at the mode.
- Drop threshold data. Binned entries such as IC50 below 1 μM were rejected from mid-2024, so exclude such values from your own filters too.
- Fetch assay text when conditions matter. It is not in the main TSV.
- Cite and respect the licence. Cite the 2025 paper and keep the licence statement for each origin, ChEMBL-derived data being share-alike.
How BindingDB relates to neighbouring resources
BindingDB imports ChEMBL entries that have a well-defined protein target, so the two overlap by design. It matches its targets to PDB structures instead of curating structures, and it supplies identifier maps to UniProt, PubChem, ChEBI, DrugBank and PubMed so records can be joined to those resources. Its own contribution, according to the paper, is the patent extraction and the extra experimental detail attached to staff-curated records.
Common misunderstandings
It is not a drug database in the DrugBank sense. BindingDB is organised around measured affinities between compounds and protein targets, and includes many compounds that are not approved drugs, particularly from patents. For drug-centred records, use a drug-centred resource.
It is not only a mirror of ChEMBL. Much of the data is imported from ChEMBL, but about half was extracted by BindingDB staff from US patents and articles, and the PubChem and host-guest sets are separate origins.
Lower values are not better data. IC50, Ki and Kd are concentrations, so smaller means a stronger binder. Comparing values requires matching measurement type, units and assay conditions; the full assay text is held in the separate Assays file.
The counts are not fixed. The website, the paper and the download files are updated on different schedules, so counts and file sizes differ by date.
Sources
- BindingDB: About BindingDB (info page), checked 2026-11-17
- BindingDB: Download page, checked 2026-11-17
- BindingDB: RESTful web services, checked 2026-11-17
- Liu T et al., BindingDB in 2024: a FAIR knowledgebase of protein-small molecule binding data (NCBI PMC), checked 2026-11-17
Data: BindingDB main download files and their sizes
The main bulk download files offered by BindingDB with their format, what each contains and the size shown on the download page, compiled from the BindingDB download page for comparison when choosing a file.
Period covered: 2026-10-31.
| File | Format | Size (MB) | Contents |
|---|---|---|---|
| All data (TSV) | TSV | 566.75 | All binding data; assay descriptions excluded and supplied in a separate Assays file |
| All data, 2D structures (SDF) | SDF | 1490 | Compound records with 2D structures |
| All data, 3D structures (SDF) | SDF | 3070 | Compound records with 3D structures |
| MySQL dump | SQL | 248.74 | Database dump |
Sources
- BindingDB download page (accessed 2026-11-17)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.