Bioactive glass is a surface-reactive glass that bonds to living tissue because its surface converts, in contact with body fluid, into a bone-like hydroxycarbonate apatite layer. The original and best-known composition is 45S5 (45 SiO2, 24.5 Na2O, 24.5 CaO, 6 P2O5 by weight), sold as Bioglass, and in the United States bioactive-glass bone-graft products are cleared by FDA through the 510(k) route as Class II devices.

This page describes materials and general use; it is not medical advice.

Definition and scope

A review of bioactive glasses in Materials states that bonding to living tissue by these glasses is mediated through the formation of an interfacial bone-like hydroxyapatite layer. The bonding ability of the 45S5 composition was first observed in rats, with bonding to bone and muscle shown six weeks after implantation. The term “bioactive” here describes this surface reaction. It is not the same meaning as a bioactive compound in pharmacology or nutrition (a molecule with a measured biological effect), which is a different topic.

The word “Bioglass” is a trade name tied to the 45S5 composition, while “bioactive glass” is the general term for the class. Bioactive glasses differ from ordinary laboratory glass such as Type I borosilicate glass in purpose and composition: laboratory glass is formulated to be chemically inert, whereas a bioactive glass is formulated to dissolve in a controlled way and react at its surface.

How bioactive glass works: the surface reaction

The mechanism usually described for silicate bioactive glass is Hench’s sequence of surface reactions. The 2018 Materials review and a 2021 review in Pharmaceuticals both describe it. In the review’s account, the glass goes through five stages after contact with body fluid:

Stage What happens at the glass surface
1 Alkali and alkaline-earth ions leave the glass and are exchanged for hydrogen ions from the fluid. Local pH rises and Si-O-Si bonds in the network break.
2 Silicon is released into the fluid as silanol groups, Si(OH)4.
3 Below about pH 9.5, the silanol groups condense into a silica gel layer on the surface.
4 Calcium and phosphate ions migrate to the gel and form an amorphous calcium phosphate layer on top of it.
5 The calcium phosphate layer takes up carbonate and crystallises into hydroxycarbonate apatite (HCA), the bone-like mineral that bonds to tissue.

The practical point for anyone reading a materials datasheet or a paper is that the first stage consumes sodium and calcium ions and raises pH. Compositions that leach many alkali ions raise the local pH more, which is the root of the cytotoxicity concern listed under limitations below.

Composition and the main families

Bioactive glasses are grouped by the oxide that forms the glass network. The Materials review lists glasses with a single network former (silicate, phosphate and borate glasses) and mixed ones such as borosilicate, phosphosilicate and borophosphate glasses. The Pharmaceuticals review tabulates several named compositions, of which two are compared here.

Composition SiO2 Na2O CaO P2O5
45S5 (Bioglass) 45 24.5 24.5 6
S53P4 (BonAlive) 53 23 20 4

All values are weight percent, from Table 1 of the Pharmaceuticals review. The same table also lists 13-93 and the borate glasses 13-93B1 and 13-93B3, which show that the family extends beyond silicate glasses.

The Pharmaceuticals review also separates two reactivity classes. Class A materials are osteoproductive and form HCA within hours, while Class B materials are osteoconductive and form it over days. Composition, mainly silica content and the share of network modifiers, is what moves a glass between these behaviours.

How the glass is made

The review describes two main routes. In melt-quenching, the batch is heated above roughly 1300 °C and then quenched to freeze the disordered atomic structure of the melt into an amorphous glass. In the sol-gel route, inorganic or organic precursors go through hydrolysis, condensation, drying and heat treatment, and the route can produce powders, nanoparticles, fibres or coatings. See how a sol becomes a gel for the chemistry of that second route.

Where bioactive glass is used

The reviews list a set of applications in which the surface reaction is useful, and name several products:

  • Middle-ear repair. The Materials review cites FDA approval in 1985 of the first 45S5 Bioglass implant, a middle-ear ossicular repair device.
  • Periodontal bone defects. 45S5 particulate is marketed under the trade name PerioGlas for filling periodontal bone defects.
  • Injectable pastes and putties. Later offered under the trade name NovaBone.
  • Scaffolds and coatings. The Pharmaceuticals review lists bone grafts, dental implant coatings, enamel and dentin remineralisation, wound healing with a borate dressing, and 3D-printed scaffolds. Enamel work is covered on the enamel remineralisation page.
  • Ion and drug delivery. The ions released during dissolution, and drugs loaded into the glass, are research uses described in the same literature.

Dental ceramics and bioactive glass sometimes appear together in supplier catalogues, but they are different material classes. Dental ceramics are mostly restorative materials chosen for strength and appearance, not for bonding to bone.

Limitations that matter when reading a paper or a datasheet

Both reviews are explicit that the original 45S5 glass has constraints, and these explain why other compositions and processing routes exist:

  • Cytotoxicity in vitro. The Materials review says the high pH created by high doses of leached sodium caused serious cytotoxic effects in culture medium.
  • Dissolution rate. Relatively fast dissolution and resorption can disrupt natural bone remodelling.
  • Processing. Poor sintering ability makes porous three-dimensional scaffolds difficult to make, and the glass tends to crystallise on heat treatment.
  • Thermal expansion. The high coefficient of thermal expansion rules 45S5 out as an adherent coating on metal such as titanium.
  • Mechanics. The Pharmaceuticals review names poor mechanical strength and brittleness, so porous scaffolds are weak.

A useful reading habit follows from this list: when a source claims a bioactive glass scaffold, coating or paste, check which composition was used and how it was processed, because the limits above depend on both.

How FDA clears bioactive-glass devices

This is the part most overviews omit. In the United States, medical products made of bioactive glass are devices, and the openFDA 510(k) database shows how a set of them were cleared. The data table below compares seven 510(k) records whose device names include bioactive glass or Bioglass, with applicant, decision date, product code and clearance type.

Two product codes carry most of them. Product code LYC is named “Bone Grafting Material, Synthetic” in the openFDA classification database, Class 2, regulation number 872.3930, in the dental specialty. Product code MQV is “Filler, Bone Void, Calcium Compound”, Class 2, regulation number 888.3045. The earliest record in the table is a 1988 Bioglass dental ridge maintainer under LYC, and the latest is a 2017 bioactive glass foam under MQV. All seven carry the decision “Substantially Equivalent”, the 510(k) outcome, and none is a premarket approval.

For how to read these records, see FDA 510(k) data and Class II medical devices. Clearance describes the device and its cleared indications. It does not rank one product above another, and a 510(k) number does not by itself describe a composition.

A checklist for reading a bioactive-glass claim

Combining the mechanism, the families and the regulatory records gives a short checklist for reading a paper, a datasheet or a catalogue entry. Each item follows from a source above.

  1. Which composition? Name the oxide percentages or the grade (45S5, S53P4, 13-93, a borate glass). The reaction speed and the pH behaviour depend on it.
  2. Which processing route? Melt-quenching and sol-gel produce different forms (monolithic glass, powders, fibres, coatings), and the 45S5 sintering and crystallisation limits affect scaffolds.
  3. What form is the product? Particulate, paste or putty, foam, coating or scaffold. The records in the data table show particulate, a foam and a demineralised-bone mixture.
  4. Which regulatory record applies? Look for the 510(k) number and the product code, then read the classification entry for that code rather than assuming one category.
  5. Is the evidence in vitro or in a patient population? The cytotoxicity limit of 45S5 was reported in culture medium, so a cell-culture result and a cleared clinical use are different kinds of evidence.

A worked example using only the data table: the record K170917 is “Bi-Ostetic Bioactive Glass Foam”, cleared in 2017 by Berkeley Advanced Biomaterials as a Traditional 510(k) under product code MQV, which openFDA names “Filler, Bone Void, Calcium Compound”. The code tells you the device type and class (2) and points to regulation 888.3045. The record does not tell you the glass composition, which would have to come from the manufacturer’s documentation.

Common misunderstandings

“Bioactive glass” and “Bioglass” are interchangeable

Bioglass is the trade name for the 45S5 composition. Other bioactive glasses, such as S53P4 or the borate 13-93 family, have different compositions and different behaviour.

Bioactive means the glass is inert and simply sits in the body

The opposite is true. The glass is designed to react: ions leach out, a gel forms and HCA crystallises, which is the bonding mechanism.

All bioactive glasses are silicate glasses

Phosphate and borate glasses, and mixed formers, are also described in the literature, with the borate 13-93B1 and 13-93B3 compositions listed in the 2021 review.

A bioactive glass product is one regulatory category

The records above show at least two product codes, with different regulation numbers and specialties, so the label “bioactive glass” does not map to one device type.

Sources

Data: FDA 510(k) records for bioactive glass bone-graft devices, 1988-2017

Seven 510(k) records from the FDA openFDA device database whose device names include bioactive glass or Bioglass, compiled with applicant, decision date, product code, the product code's classification name and the 510(k) type. Product codes LYC (Bone Grafting Material, Synthetic) and MQV (Filler, Bone Void, Calcium Compound) are both Class 2 in the openFDA classification database. All seven decisions were Substantially Equivalent. Data read 2026-11-18.

Period covered: 1988-2017.

FDA 510(k) records for bioactive glass bone-graft devices, 1988-2017
510(k) numberDevice nameApplicantDecision dateProduct codeProduct code name510(k) type
K880371Bioglass Dental Endosseous Ridge MaintainerAmerican Biomaterials Corp.1988-11-18LYCBone Grafting Material, SyntheticTraditional
K952922Biogran Bioactive Glass Synthetic Bone Graft MaterialOrthovita Co.1995-12-19LYCBone Grafting Material, SyntheticTraditional
K962494PerioGlas - Bioglass Bone Graft ParticulateUsbiomaterials Corp.1996-09-20LYCBone Grafting Material, SyntheticTraditional
K000149NovaBone-Bioglass Bone Graft ParticulateUsbiomaterials Corp.2000-02-07LYCBone Grafting Material, SyntheticSpecial
K062459Origen DBM with Bioactive GlassNanotherapeutics2007-02-26MQVFiller, Bone Void, Calcium CompoundTraditional
K110976Origen DBM with Bioactive Glass, Nanofuse DBMNanotherapeutics, Inc.2011-05-03MQVFiller, Bone Void, Calcium CompoundSpecial
K170917Bi-Ostetic Bioactive Glass FoamBerkeley Advanced Biomaterials2017-10-30MQVFiller, Bone Void, Calcium CompoundTraditional

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Bioactive Glass: Composition, Mechanism and FDA Clearance

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →