Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop centrifuge blood layers supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Centrifuge Blood Layers: Plasma, Buffy Coat and Red Cells

What the three layers of centrifuged blood are, which tubes produce them, and how published protocols collect plasma or buffy coat.

Written and maintained by CASRAI Editorial Board

Published

On this page

After a centrifuge spin, anticoagulated whole blood separates into three layers: a pale yellow plasma layer on top, a thin yellowish buffy coat in the middle, and packed red blood cells at the bottom. The layers form because the spin pulls the denser components toward the bottom of the tube, so the red cells pack down while the plasma stays above them. Which layers you actually get depends on the tube: a tube with no additive gives serum and a clot, and a gel tube adds a physical barrier.

This page describes products and general use; it is not medical advice.

It is written for researchers, lab technicians and biobank staff who spin blood in a lab and need to know what each layer is, which tube produces it, and how published protocols handle the boundary between layers. For spin settings by tube type, see centrifuging blood samples. For isolating cells from the interface with a density gradient, see isolating PBMCs.

What the layers are

A blood centrifuge, whether a bench model or a larger swing-bucket unit (see what is a centrifuge), does not create the layers. It speeds up a separation that would otherwise take far longer under gravity alone. In anticoagulated blood the result, from top to bottom, is as follows.

Plasma (top layer)

Plasma is the clear, pale yellow liquid above the cell pellet. STEMCELL Technologies describes it in exactly those terms in its plasma collection protocol: after the spin, pale yellow plasma sits above the red blood cell pellet. Plasma is the fluid fraction of blood that has not clotted, which is why it only exists when the sample was collected with an anticoagulant.

Buffy coat (middle layer)

The buffy coat is the thin yellowish layer between the plasma and the packed red cells. The Crimson Core biobank biobank procedure for buffy coat processing describes it as a yellowish layer lying over the packed red blood cells, with plasma above it. It is the layer that holds the white blood cells, which is why biobanks and DNA workflows collect it deliberately, while plasma workflows try to avoid it.

Packed red blood cells (bottom layer)

The red cells form the dense pellet at the bottom of the tube. STEMCELL refers to this as the RBC pellet and uses it as the reference point for how much plasma to leave behind when aspirating. The Crimson Core plasma procedure also refers to the buffy-coat layer overlying the packed red cells, which tells you that the interface just above the pellet is the part to protect when the goal is clean plasma.

Which tubes give which layers

Not every tube produces the same three layers. The additive in the tube decides whether you get plasma or serum, and whether a gel barrier sits between the fluid and the cells. The University of Utah WebPath phlebotomy tutorial and the Crimson Core plasma procedure describe the common tube types used in labs. The table below summarizes what each source says about the result of centrifugation; it is general information, and the tube manufacturer’s instructions for use and your own SOP decide the actual handling.

Tube (top colour) Additive described by the source What centrifugation gives Source
Red, no additive None Serum, after the blood clots and is spun University of Utah WebPath
Gold, serum separator (SST) Gel at the bottom and clot activator Serum, with the gel separating it from the blood cells University of Utah WebPath
Lavender or purple, EDTA EDTA, which chelates calcium Plasma above the cells in an uncoagulated sample University of Utah WebPath; Crimson Core
Light green, plasma separator (PST) Lithium heparin with gel Plasma, separated from the cells by gel at the bottom University of Utah WebPath
Green, lithium heparin Lithium heparin Plasma above the cells Crimson Core
Light blue, sodium citrate Sodium citrate (used for coagulation testing; full draw) Plasma above the cells University of Utah WebPath; Crimson Core

The practical point is this: if the sample has clotted, or if it sits in a serum tube, you are looking at serum and a clot rather than plasma, a buffy coat and red cells. Our guides to the red top tube additive and the serum separation tube cover those two cases in detail.

The Crimson Core plasma procedure lists the tube volumes it works with: purple EDTA tubes of 4.0 mL and 10 mL, green lithium heparin tubes of 4, 5 and 10 mL, green gel tubes of 5 and 10 mL, blue sodium citrate tubes of 3, 5 and 10 mL (for coagulation work), and a less common yellow ACD tube of 10 mL. Tube volume affects how tall the plasma column is, so it affects how you judge the aspiration height described below.

Example spin settings from published protocols

There is no single universal setting, and the two sources read for this page differ in how they express speed. STEMCELL gives relative centrifugal force (RCF, written as × g), while the Crimson Core procedures give revolutions per minute (rpm). RCF depends on the rotor radius and rpm does not, so a number in rpm only transfers to another centrifuge if the rotor is the same; see RCF vs RPM and how to convert before copying a protocol. The data table below compares the settings each source states. Its figures are examples from those protocols, not a recommendation for your samples.

Plasma collection before cell isolation (STEMCELL)

STEMCELL’s protocol collects blood with an appropriate anticoagulant and spins it at 2,000 to 2,500 × g for 10 to 15 minutes at room temperature (15 to 25 °C), with the brake off. The brake instruction matters: a hard stop can disturb the layers that the spin has just formed, so the deceleration setting is part of the protocol rather than a detail. The protocol then describes aspirating the plasma and leaving about 1 cm of plasma above the red blood cell pellet, lowering the pipette tip gradually with the tip at the liquid surface as the level drops.

It also describes an optional second spin at the same settings for work with extracellular vesicles, followed by a 0.8 µm filter or a 10,000 × g spin for 30 minutes to remove large vesicles. Those later steps are specific to vesicle studies and are not needed for ordinary plasma collection.

Buffy coat processing (Crimson Core)

The Crimson Core buffy coat procedure spins at 3,000 rpm for 10 minutes at 25 °C, and notes that temperatures from 4 to 42 °C are allowed when the study protocol calls for it. The operator pipettes off the plasma first, leaving no more than 0.5 mL over the cell interface. A separate single-use pipette then collects as much of the yellow layer as possible, generally under 0.5 mL, taking care to avoid plasma and red cells, and the buffy coat goes into a sterile tube or cryovial.

Plasma processing (Crimson Core)

For plasma, the Crimson Core procedure uses the same 3,000 rpm, 10 minutes and 25 °C, and tells the operator to avoid the buffy-coat layer that overlies the packed red cells.

Collecting one layer without mixing it with the next

The two protocols above ask for opposite things at the same boundary, and that contrast is the most useful thing to take from them. When the goal is plasma, the interface is something to stay away from. STEMCELL leaves about 1 cm of plasma above the pellet, a generous margin. When the goal is the buffy coat, the interface is the product. Crimson Core leaves no more than 0.5 mL of plasma over the cell layer so that a second pipette can reach it, and the buffy coat volume it expects is generally under 0.5 mL.

Goal Pipette tip position What is left behind
Plasma only (STEMCELL) At the liquid surface, lowered gradually as the level falls About 1 cm of plasma above the red cell pellet
Buffy coat (Crimson Core) First pipette: plasma. Second single-use pipette: the yellow layer No more than 0.5 mL of plasma over the cells before the second pipette; red cells stay in the tube

Why a second spin is sometimes used

QIAGEN’s technical FAQ on plasma preparation answers directly that double centrifugation is not required, and adds that a second centrifugation step helps remove traces of buffy coat that were carried over when the plasma was aspirated after the first spin. In other words, the second spin is a clean-up option for downstream assays that are sensitive to cellular contamination, and it is not part of the basic three-layer separation. STEMCELL’s optional second spin for vesicle work is the same idea applied to a more demanding downstream use.

Reading the tube before you touch it

Before aspirating anything, check that the spin has produced the layers you expect. The reference points in the sources are visual: pale yellow plasma on top, a yellowish layer over the cells, and a red pellet at the bottom. Both source protocols assume a distinct boundary between the layers. Which of the settings above is appropriate is a question for the protocol that governs your samples, not for a general reference.

Common mistakes

  • Leaving the brake on. STEMCELL specifies the brake off for plasma collection, so using a rapid deceleration setting departs from the protocol and risks disturbing the boundary.
  • Copying rpm without checking the rotor. A setting in rpm from one centrifuge does not give the same force on a rotor with a different radius. Convert to RCF first, or confirm the rotor.
  • Aspirating too close to the interface for plasma. Both Crimson Core and STEMCELL tell the operator to stay off the buffy coat when plasma is the goal. QIAGEN notes that the carried-over buffy coat is what a second spin removes.
  • Using the wrong tube for the expected layers. A serum tube gives serum and a clot. Expecting a buffy coat from it is a tube-selection error rather than a centrifuge fault.
  • Mixing up tube types by cap colour alone. Colour conventions are broad; the additive on the tube label and the manufacturer’s instructions for use are what define the contents.
  • Ignoring the study protocol’s temperature range. Crimson Core’s default is 25 °C but it allows 4 to 42 °C when the study protocol says so, so the temperature setting should come from the protocol rather than habit.

Safe handling basics

Blood samples are handled according to the institution’s biosafety rules and the centrifuge manufacturer’s instructions. Tubes must be balanced and loaded as the instrument’s manual requires; the rotor and bucket rules are in the instrument manual. The protocols used here do not give instructions for drawing blood, and this page does not either; collection technique belongs in a clinical SOP.

Sources

Data: Example centrifugation settings for plasma and buffy coat collection in published protocols

Compares the spin speed, time, temperature, brake setting and aspiration margin stated in published protocols from STEMCELL Technologies and the Crimson Core biobank biobank for plasma and buffy coat collection. Values are copied as stated by each source; speeds are given as written (x g or rpm) and are not converted.

Example centrifugation settings for plasma and buffy coat collection in published protocols
ProtocolGoalSpeedTime (min)TemperatureBrakeLeft behind at the interface
STEMCELL plasma collectionPlasma2000-2500 x g10-1515-25 C (room temperature)OffAbout 1 cm of plasma above the RBC pellet
STEMCELL optional second spin (vesicle work)Plasma, further clearedSame as first spinSame as first spinSame as first spinOffNot stated
Crimson Core plasma processingPlasma3000 rpm1025 CNot statedAvoid the buffy-coat layer over packed red cells
Crimson Core buffy coat processingBuffy coat3000 rpm1025 C (4-42 C if the study protocol allows)Not statedNo more than 0.5 mL of plasma over the cell interface before collecting the layer

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Centrifuge Blood Layers: Plasma, Buffy Coat and Red Cells

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →