Skip to main content
v2026.11,986 entries · CC-BY 4.0

Chemical Oxygen Demand: Testing & Standards Guide

Chemical oxygen demand (COD) quantifies chemically oxidizable compounds in wastewater and surface water using standardized closed-reflux dichromate methods.

Written and maintained by CASRAI Editorial Board

Published

On this page

Short answer

Chemical oxygen demand (COD) is an environmental analytical test that quantifies the mass of oxygen required to chemically oxidize organic and inorganic pollutants in water. Using a boiling mixture of potassium dichromate and sulfuric acid, the test rapidly oxidizes biodegradable and refractory compounds, providing actionable effluent compliance and water quality metrics within two hours.

Definition and scope

In water testing, chemical oxygen demand cod measures organic contamination in aquatic matrices. To understand COD, analysts evaluate what is oxygen demand: the mass of dissolved oxygen consumed per liter of water (in mg O₂/L) as pollutants degrade. Untreated discharges deplete dissolved oxygen in receiving streams, endangering aerobic aquatic life.

The analytical scope distinguishes between chemical oxygen consumption via strong oxidants and biological respiration by microbes. While biological assays take days, COD provides rapid oxidation under controlled thermal conditions across surface water, municipal sewage, and industrial discharges. High-precision testing requires preparing blanks with ASTM Type II reagent water to prevent background bias.

How it works or how it is used in practice

The standard COD assay follows the closed-reflux method in U.S. EPA Method 410.4, Standard Methods 5220, and ISO 15705:2002. A sample is digested with potassium dichromate (K₂Cr₂O₇) in concentrated sulfuric acid (H₂SO₄) at 150 °C for two hours in sealed borosilicate vials. Hexavalent chromium (Cr₂O₇²⁻) oxidizes organic compounds to carbon dioxide and water while reducing to green trivalent chromium (Cr³⁺):

CₙHₐO₆N_c + d Cr₂O₇²⁻ + (8d + c) H⁺ → n CO₂ + [(a + 8d - 3c) / 2] H₂O + c NH₄⁺ + 2d Cr³⁺

Two specific reagents ensure analytical accuracy:

  • Silver Sulfate Catalysis: Silver sulfate (Ag₂SO₄, ~22 g per 4.09 kg H₂SO₄) catalyzes the oxidation of refractory straight-chain aliphatic hydrocarbons and alcohols.
  • Mercuric Sulfate Chloride Masking: Chloride ions (Cl⁻) interfere positively by reducing dichromate to chlorine gas. Mercuric sulfate (HgSO₄) at a 10:1 ratio binds chloride into unreactive complexes up to 2,000 mg/L Cl⁻. Higher concentrations require dilution.

After digestion and cooling, consumed oxygen is quantified photometrically or titrimetrically. In colorimetric testing (EPA 410.4, SM 5220 D), green Cr³⁺ absorbance is measured at 600 nm for high ranges (100–900 mg/L COD), or yellow Cr₂O₇²⁻ at 420 nm for low ranges (3–90 mg/L COD). Bench workflows rely on UV-Vis spectrophotometer basics and periodic photometric accuracy and wavelength checks. In open-reflux titrimetric testing (SM 5220 B, ASTM D1252), unreduced dichromate is back-titrated against ferrous ammonium sulfate (FAS) with ferroin indicator.

Laboratories select among standardized analytical configurations based on matrix, compliance rules, and throughput:

Standard Method Principle Conditions Linear Range Waste Profile
Closed Reflux Colorimetric
(EPA 410.4 / SM 5220 D / ISO 15705)
Spectrophotometry at 600 or 420 nm after dichromate digestion Sealed vials; 150 °C for 2 h 3 to 900 mg/L Micro-scale (~2 mL; contains Hg and Cr)
Open Reflux Titrimetric
(SM 5220 B / ASTM D1252 Method A)
Boiling reflux with FAS back-titration 500 mL flask; 2 h reflux 50 to 800 mg/L Macro volume (1 g HgSO₄, 25 mL dichromate)
Biochemical Oxygen Demand
(EPA 405.1 / SM 5210 B)
Microbial respiration measuring dissolved oxygen loss 300 mL bottles; 20 °C for 5 days in dark 2 to 6 mg/L DO drop Zero heavy metals consumed

What is biochemical oxygen demand BOD?

A frequent comparison in water analysis is what is biochemical oxygen demand bod and how it correlates with COD. While COD chemically breaks down nearly all oxidizable matter, BOD measures oxygen consumed by living aerobic bacteria degrading organic compounds. Monitoring biochemical oxygen demand water quality reveals the biological impact of effluent on natural receiving streams.

The BOD test procedure

The standardized bod test (BOD₅) incubates a sample in sealed 300 mL glass bottles at 20 °C for five days, measuring dissolved oxygen depletion with an optical sensor. Because bacterial incubation requires days, the BOD test cannot provide immediate feedback, making COD the primary bench test for daily process control.

Where it matters for labs, clinics or supply decisions

Treatment plants monitor biological oxygen demand wastewater alongside COD to verify efficiency and satisfy NPDES permits. The ratio of 5-day biochemical oxygen demand to chemical oxygen demand (BOD₅/COD) provides a biodegradability index guiding operations:

BOD₅ / COD Ratio Biodegradability Index Typical Source Treatment Strategy
> 0.50 Readily Biodegradable Raw domestic sewage Conventional activated sludge without chemical additives.
0.30 – 0.50 Moderately Biodegradable Mixed municipal-industrial influent Extended aeration or bioaugmentation with acclimated seed.
< 0.30 Refractory / Inert Chemical manufacturing, leachate Requires coagulation, ozone, or advanced oxidation processes (AOPs).

Evaluating bod for wastewater influent and tracking the bod of waste water against rapid COD testing enables operators to adjust aeration blowers within hours. Facility managers evaluating equipment can compare specifications in our BOD incubator vs. COD reactor comparison.

Understanding wastewater bod dynamics also informs lab safety. Sealed vials reach elevated pressures at 150 °C; therefore, all digestion must take place in thermoreactor blocks with safety shields inside a certified laboratory chemical fume hood. Under EPA RCRA rules, toxic digestate containing chromium and mercury must never enter drains; spent vials must be collected in dedicated containers within satellite accumulation areas for chemical waste for licensed disposal.

Common misunderstandings

Five misconceptions recur in chemical oxygen demand testing:

  • COD and BOD measure identical fractions: COD measures virtually all chemically oxidizable compounds—including refractory organics, cellulose, and inorganic reducing agents. BOD measures only biologically accessible carbon and nitrogen. Consequently, COD is virtually always greater than BOD (COD ≥ BOD₅).
  • COD directly reflects aquatic toxicity: COD measures chemical reducing capacity, not biological toxicity. A sugar solution exhibits high COD, whereas water containing lethal trace toxins can exhibit negligible COD.
  • Chloride interference is negligible in freshwater: Unmasked chloride reacts stoichiometrically with dichromate to form chlorine gas, generating false-positive COD values. Mercuric sulfate complexation is required for all chloride-bearing samples.
  • Zero COD confirms pure water: Potassium dichromate does not oxidize certain stable aromatics (such as benzene and pyridine). Inorganic toxins like PFAS and heavy metals also exert zero COD. Complete purity requires TOC and chromatographic testing.
  • Neutralized digestate can be poured down the sink: Base neutralization neutralizes acid pH but leaves toxic dissolved chromium and mercuric salts in solution. Discharging digestate violates hazardous waste laws; vials require licensed hazardous disposal.

Frequently asked questions

Direct answers to common operational questions:

What is the primary difference between COD and BOD in wastewater?

COD measures total chemically oxidizable matter using boiling potassium dichromate in a 2-hour test. BOD measures biodegradable organic compounds consumed by aerobic bacteria during a 5-day incubation at 20 °C. COD is faster and produces higher values than BOD.

Why does the COD test require two hours while the BOD test requires five days?

The COD test uses severe chemical conditions—150 °C heat, sulfuric acid, silver catalyst, and hexavalent chromium—to rapidly force oxidation. The BOD test relies on living bacterial cultures at 20 °C, which require days to metabolize organic substrates.

How does mercuric sulfate prevent chloride interference in COD testing?

Chloride oxidizes to chlorine gas during digestion, producing false-positive COD readings. Adding mercuric sulfate selectively complexes chloride into stable mercuric chloride complexes [HgCl₄]²⁻, neutralizing interference up to 2,000 mg/L Cl⁻.

What does a high COD value indicate in industrial effluent?

A high COD indicates heavy chemical pollutant loading from solvents, hydrocarbons, food waste, or industrial byproducts. Untreated high-COD effluent rapidly depletes dissolved oxygen in receiving rivers, killing aquatic life and violating discharge permits.

Can chemical oxygen demand testing be performed without hazardous heavy metals?

Milder oxidants like permanganate avoid mercury and silver but fail to oxidize complex aliphatic compounds. Total Organic Carbon (TOC) analyzers provide a non-toxic instrumental alternative, though dichromate digestion remains the reference standard under EPA 410.4.

Sources

Analytical procedures were verified against official standards:

  • U.S. Environmental Protection Agency (USEPA) (1993): Method 410.4, Revision 2.0: The Determination of Chemical Oxygen Demand by Semi-Automated Colorimetry. EPA Method 410.4 Document. Read 2026-11-10.
  • APHA, AWWA, WEF: Standard Methods for the Examination of Water and Wastewater, Method 5220 Chemical Oxygen Demand (COD). Standard Methods 5220 Overview. Read 2026-11-10.
  • International Organization for Standardization (ISO): ISO 15705:2002: Water quality — Determination of the chemical oxygen demand index (ST-COD) — Small-scale sealed-tube method. ISO 15705:2002 Specification. Read 2026-11-10.
  • Hach Company: Hach Method 8000: Oxygen Demand, Chemical (Reactor Digestion Method). Hach Method 8000 Technical Document. Read 2026-11-10.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Chemical Oxygen Demand: Testing & Standards Guide

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →