Written and maintained by CASRAI Editorial Board
Published
On this page
A laboratory copper sulfate safety data sheet (SDS) details critical physical, health, and environmental hazards for both copper(II) sulfate pentahydrate (CAS 7758-99-8) and anhydrous copper sulfate (CAS 7758-98-7). Classified under the Globally Harmonized System (GHS) as Acute Toxicity Oral Category 4 (H302), Serious Eye Damage Category 1 (H318), Skin Irritation Category 2 (H315), and Aquatic Acute/Chronic Category 1 (H400/H410), copper sulfate requires strict exposure controls to remain below the 1 mg/m³ OSHA permissible exposure limit (PEL as Cu). Safe handling mandates chemical splash goggles, impervious nitrile or neoprene gloves, lab coats, and dedicated dust containment to prevent ocular injury, mucosal irritation, and heavy-metal aquatic contamination.
Short answer: What does a copper sulfate SDS require?
Working with copper(II) sulfate in analytical, academic, or industrial research laboratories requires rigorous adherence to the chemical safety profile outlined across the standard 16-section Safety Data Sheet format. Under OSHA’s Hazard Communication Standard (29 CFR 1910.1200) and international GHS standards, copper sulfate presents a multifaceted hazard profile dominated by irreversible ocular damage, oral toxicity, and acute aquatic ecotoxicity. Because copper is a regulated transition metal, standard laboratory practice strictly prohibits sink disposal of residual solutions or rinsing concentrated residues down sanitary drains.
Bench scientists and environmental health and safety (EHS) officers must recognize that standard safety glasses with side shields do not satisfy eye-protection mandates when weighing or dissolving solid copper sulfate. Fine airborne particles or splashes from aqueous solutions pose a severe risk of corneal clouding, conjunctival burning, and permanent visual impairment. Consequently, chemical splash goggles or full face shields are non-negotiable personal protective equipment (PPE). Engineering controls such as certified chemical fume hoods or local exhaust ventilation must be utilized whenever dry crystal manipulation creates dust concentrations approaching the 1 mg/m³ 8-hour time-weighted average (TWA) threshold established by OSHA and ACGIH.
The sections below detail the chemical differences between hydration states, explain GHS classification variances between major regulatory bodies and chemical manufacturers, provide benchtop handling and PPE matrices, review violent chemical incompatibilities, and outline standard precipitation-based neutralization and hazardous waste disposal protocols. The data table below compares the physical parameters, GHS hazard codes, regulatory exposure limits, and ecotoxicity thresholds across anhydrous and pentahydrate copper sulfate.
Chemical identity, hydration states and physical properties
Safety data sheets for copper sulfate encompass two primary chemical entities that differ substantially in molecular weight, crystal structure, visual appearance, and thermodynamic behavior during dissolution: anhydrous copper(II) sulfate and copper(II) sulfate pentahydrate. Choosing the correct compound identifier on chemical inventories and secondary container labels is critical for stoichiometric calculations, reagent preparation, and accurate hazard communication.
Anhydrous Copper(II) Sulfate (CAS 7758-98-7): Also identified as cupric sulfate anhydrous, this form has a molecular formula of CuSO4 and a molecular weight of 159.61 g/mol. In its purest form, anhydrous copper sulfate presents as a hygroscopic, off-white to greenish-gray crystalline powder or rhombic crystals. Because it lacks coordinated water molecules, it possesses a high affinity for moisture, readily absorbing ambient humidity to convert into hydrated forms. Importantly for laboratory safety, the hydration and dissolution of anhydrous copper sulfate in water is a markedly exothermic reaction. When preparing stock solutions from bulk anhydrous powder, bench chemists must add the powder gradually to agitated water rather than pouring water onto a compacted bed of powder, which can cause localized boiling, thermal stress on glassware, and violent splattering.
Copper(II) Sulfate Pentahydrate (CAS 7758-99-8): Commonly designated as blue vitriol, bluestone, or cupric sulfate 5-hydrate, this is the most prevalent form encountered in biological, chemical, and educational laboratories. Its chemical formula is CuSO4 · 5H2O, with a molecular weight of 249.68 g/mol. It forms brilliant, deep blue triclinic crystals or granules with a specific gravity of 2.28. In aqueous solution, both compounds yield hydrated cupric cations [Cu(H2O)6]2+ and sulfate anions, imparting a characteristic sky-blue coloration and creating an acidic solution with a typical pH range of 3.5 to 4.5 for a 5% aqueous solution at 20 °C.
Understanding the molecular mass disparity between the two forms is a frequent source of error in laboratory protocols. Because water of crystallization accounts for approximately 36.1% of the pentahydrate’s mass, substituting one form for the other without adjusting stoichiometry leads to severe experimental discrepancies or inadvertent over-concentration of toxic cupric ions. For instance, when formulating analytical reagents such as the alkaline copper tartrate working solution in the classic Lowry method or the bicinchoninic acid assay, protocols specify exact molar ratios of cupric ions. Researchers preparing these reagents frequently consult our guide on BCA protein assay working reagent preparation to verify stoichiometric concentration limits and avoid precipitation errors.
Thermally, copper sulfate pentahydrate decomposes stepwise upon heating. At temperatures between 63 °C and 110 °C, the crystal loses four coordinated water molecules to form the monohydrate (CuSO4 · H2O). Further heating above 200 °C eliminates the final water molecule, yielding the off-white anhydrous salt. However, if exposed to thermal extremes above 650 °C—such as during a structural laboratory fire—copper sulfate decomposes completely, releasing dense, highly toxic sulfur dioxide (SO2), sulfur trioxide (SO3), and toxic copper fume. These decomposition products pose severe inhalation risks that mirror the acid-gas hazards detailed in our sulfuric acid safety data sheet guide.
GHS hazard classifications, pictograms and signal words
Section 2 of a GHS-compliant copper sulfate SDS identifies the standardized hazard classifications, signal words, hazard statements (H-codes), and precautionary statements (P-codes). While minor discrepancies exist among commercial chemical vendors (such as Thermo Fisher Scientific, MilliporeSigma, and Spectrum Chemical), international consensus established by the European Chemicals Agency (ECHA) CLP Annex VI and the United Nations GHS framework classifies pure copper sulfate under the signal word DANGER.
The primary GHS hazard classes assigned to copper sulfate include:
- Acute Toxicity, Oral (Category 4, H302): Harmful if swallowed. Ingesting concentrated copper sulfate induces severe gastrointestinal distress, burning epigastric pain, metallic taste, nausea, violent vomiting, and osmotic diarrhea. In severe clinical cases, systemic copper absorption induces acute intravascular hemolysis, methemoglobinemia, acute tubular necrosis, and acute hepatic failure. Commercial rat oral median lethal dose (LD50) values range between 300 mg/kg and 960 mg/kg depending on the hydration state, vehicle, and laboratory test conditions.
- Serious Eye Damage / Eye Irritation (Category 1, H318): Causes serious eye damage. Exposure of the ocular surface to solid particles or concentrated solutions causes severe chemical conjunctivitis, blepharospasm, palpebral edema, corneal ulceration, and permanent stromal clouding. While select older vendor sheets list Category 2A (H319: Causes serious eye irritation), regulatory consensus under ECHA Harmonized CLP classification designates Category 1 due to demonstrated risks of irreversible ocular tissue destruction.
- Skin Corrosion / Irritation (Category 2, H315): Causes skin irritation. Prolonged or repeated dermal contact with dusts or concentrated solutions strips natural skin lipids, eliciting erythema, pruritus, dermatitis, and localized chemical burns, especially under humid bench conditions or beneath occlusive rings and wristbands.
- Hazardous to the Aquatic Environment, Acute Hazard (Category 1, H400): Very toxic to aquatic life. Cupric ions disrupt osmoregulatory mechanisms and enzyme systems in aquatic organisms at sub-parts-per-million concentrations. ECHA assigns an acute M-factor (multiplying factor) of 10 to copper sulfate.
- Hazardous to the Aquatic Environment, Long-Term Hazard (Category 1, H410): Very toxic to aquatic life with long lasting effects. Inorganic copper ions do not biodegrade, partitioning into aquatic sediments and bioaccumulating in benthic macroinvertebrates and freshwater fish species.
The required GHS pictograms appearing on container labels and SDS header sections are the Corrosion pictogram (GHS05, representing irreversible eye damage), the Exclamation Mark pictogram (GHS07, representing acute oral toxicity and skin irritation), and the Environment pictogram (GHS09, depicting a dead tree and dying fish, representing aquatic ecotoxicity). When handling technical-grade powders that generate fine aerosols, some vendor dossiers also incorporate the Skull and Crossbones pictogram (GHS06) if local criteria for acute oral or inhalation toxicity thresholds fall within Category 3 parameters.
Precautionary statements mandated on copper sulfate labels require strict operational safeguards: P264 (wash hands thoroughly after handling), P270 (do not eat, drink, or smoke when using this product), P273 (avoid release to the environment), P280 (wear protective gloves, protective clothing, and eye/face protection), P301+P312 (if swallowed, call a poison center or doctor), P305+P351+P338 (if in eyes, rinse cautiously with water for several minutes, remove contact lenses if present and easy to do, continue rinsing), P310 (immediately call a poison center or physician), and P501 (dispose of contents and container in accordance with local, regional, and national hazardous waste regulations).
Laboratory exposure limits and health hazards
Occupational safety agencies evaluate copper sulfate exposures under the overarching category of copper dusts and mists. Because inhalation of airborne cupric salts irritates the upper respiratory tract and induces systemic toxicity upon systemic absorption, strict occupational exposure limits (OELs) govern laboratory environments.
The authoritative regulatory thresholds across US and international safety bodies include:
- OSHA Permissible Exposure Limit (PEL): 1 mg/m³ as an 8-hour time-weighted average (TWA) for copper dusts and mists (as Cu), codified under 29 CFR 1910.1000 Table Z-1. Employers are legally required to maintain laboratory airborne copper concentrations below this ceiling.
- NIOSH Recommended Exposure Limit (REL): 1 mg/m³ as a 10-hour TWA for copper dusts and mists (as Cu), established in the NIOSH Pocket Guide to Chemical Hazards.
- ACGIH Threshold Limit Value (TLV): 1 mg/m³ as an 8-hour TWA (inhalable particulate matter, as Cu) for copper dusts and mists.
- NIOSH Immediately Dangerous to Life or Health (IDLH): 100 mg/m³ (as Cu). At this concentration, acute respiratory spasm, severe pulmonary irritation, and systemic copper intoxication pose an immediate threat to life or irreversible health impairment.
- ILO/WHO International Guidance Values: Certain national jurisdictions enforcing European health standards recommend a stricter respirable fraction limit of 0.01 mg/m³ for soluble copper salts to prevent chronic occupational bronchitis and subclinical metal fume-like pulmonary responses.
Health effects from acute exposure manifest rapidly depending on the exposure pathway. Inhalation of copper sulfate dust triggers intense coughing, sneezing, retrosternal chest tightness, rhinorrhea, and ulceration of the nasal septum in chronic settings. Inhaling hot decomposition fumes may trigger metal fume fever—characterized by chills, fever, malaise, headache, and a persistent metallic aftertaste. Dermal exposure to intact skin causes localized irritation, but contact with abraded or eczematous skin accelerates systemic uptake. Chronic exposure in individuals with impaired biliary copper excretion (such as undiagnosed Wilson disease) presents grave toxicological risks due to hepatic and basal ganglia copper accumulation.
In contrast to non-toxic laboratory salts such as sodium sulfate, which exhibit minimal systemic toxicity as discussed in our sodium sulfate handling protocols guide, copper sulfate demands strict heavy-metal hygiene. Bench surfaces must never be dry-swept, and food, beverages, and cosmetic application are strictly forbidden in analytical spaces where copper salts are processed.
Handling protocols, PPE and benchtop engineering controls
Safely handling copper sulfate requires an integrated hierarchy of controls combining engineering design, administrative protocols, and targeted personal protective equipment. Laboratory supervisors must establish standard operating procedures (SOPs) covering dispensing, weighing, solution preparation, and secondary container labeling.
Engineering Controls: Bulk containers of copper sulfate must be opened and weighed inside an operating chemical fume hood or a dedicated powder containment enclosure equipped with certified HEPA filtration. If weighing analytical quantities on an open microbalance is unavoidable, bench personnel must utilize draft shields, anti-static ionizers to prevent powder dispersal, and pre-moistened containment trays beneath balances to capture stray crystals without generating airborne dust.
Personal Protective Equipment (PPE) Matrix:
- Eye and Face Protection: Standard safety spectacles with side shields provide inadequate defense against liquid splashes or electrostatic powder jumps. Personnel must wear indirect-vent chemical splash goggles meeting ANSI Z87.1 (or EN 166) standards. When dissolving large batches or pouring volumes exceeding 500 mL of concentrated copper sulfate solutions, an ANSI-approved face shield must be worn over the goggles.
- Hand Protection: Disposable nitrile examination gloves (minimum thickness 4 to 6 mil) offer effective barrier protection for routine, short-duration bench handling. For prolonged handling of bulk powders, concentrated stock solutions, or spill remediation, thick nitrile, neoprene, or polyvinyl chloride (PVC) chemical-resistant gloves are recommended. Personnel should inspect gloves for pinholes prior to use and execute prompt glove changes if splash contamination occurs.
- Body Protection: Standard laboratory coats made of 100% cotton or flame-resistant fabric must be fully buttoned at all times. Long trousers and closed-toe, impermeable shoes are required. In high-dust industrial formulation suites, disposable Tyvek coveralls prevent particulate accumulation on personal clothing.
- Respiratory Protection: Under normal fume hood operation, respiratory equipment is not required. However, for operations outside containment where dust concentrations exceed or approach the 1 mg/m³ PEL, or during spill cleanup operations, workers must wear a NIOSH-approved half-face air-purifying respirator fitted with N100 or P100 particulate filters. If acidic fumes or volatile decomposition gases are suspected, combination cartridges incorporating acid gas sorbents (OV/AG/P100) are mandatory.
Administrative rules require that all secondary containers—including wash bottles, volumetric flasks, and dropper bottles—bear GHS-compliant labeling detailing the chemical name, CAS number, signal word, and core hazard pictograms. Solutions must never be stored in unlabelled glassware or food-grade vessels, even temporarily.
Chemical incompatibilities and reactive hazard management
Section 10 of a copper sulfate SDS addresses chemical stability and reactivity. While copper sulfate is thermally stable under normal ambient warehouse and bench conditions, it exhibits hazardous and violent incompatibilities with several common laboratory reagents. Failure to recognize these chemical incompatibilities can result in fire, toxic gas generation, or violent explosions.
Key reactive hazards include:
- Hydroxylamine and Hydroxylamine Salts: Anhydrous copper sulfate acts as a violent oxidation catalyst, causing pure hydroxylamine to ignite spontaneously upon contact. Hydrated copper sulfate reacts vigorously with hydroxylamine solutions, releasing immense heat and gaseous decomposition products. Under no circumstances should copper salts be mixed with hydroxylamine reagents without engineered cooling and blast attenuation.
- Acetylene Gas: Passing acetylene through aqueous or ammoniacal copper sulfate solutions results in the precipitation of cuprous acetylide (Cu2C2), a highly unstable, sensitive primary explosive. Copper acetylide detonate upon drying from mild friction, mechanical shock, or heat. Copper piping, valves, or tubing must never be utilized in acetylene delivery manifolds.
- Active Metals (Magnesium, Aluminum, Zinc, Iron): Cupric ions possess a high standard reduction potential (+0.34 V for Cu2+/Cu). When copper sulfate solutions encounter electrochemically active metals such as magnesium powder, zinc dust, or aluminum shavings, a rapid single-displacement redox reaction ensues. In the case of magnesium or zinc, the reaction is violently exothermic, rapidly boiling the solution and releasing flammable hydrogen gas (H2), creating an acute fire and explosion hazard.
- Strong Bases and Caustic Alkalis: Combining copper sulfate with concentrated sodium hydroxide (NaOH) or potassium hydroxide (KOH) produces an immediate, highly exothermic precipitation of gelatinous cupric hydroxide [Cu(OH)2]. Without controlled cooling, the localized heat buildup can shatter unrated glass beakers. Upon heating, cupric hydroxide dehydrates to form black cupric oxide (CuO).
- Reducing Agents and Strong Reducing Compounds: Reagents such as sodium borohydride, sodium hypophosphite, or hydrazine reduce cupric ions to metallic copper or cuprous oxide, often accompanied by rapid gas evolution and thermal spikes. In biochemical applications involving reducing agents, researchers must review compatibility protocols, such as those detailed in our guide on b-mercaptoethanol laboratory uses and safety.
- Hygroscopic Storage Incompatibilities: Because anhydrous copper sulfate absorbs moisture aggressively, storing it adjacent to moisture-sensitive salts—such as those described in our calcium chloride safety profile —can compromise packaging integrity and induce caking or hydration degradation.
Copper sulfate must be segregated in chemical storage cabinets dedicated to inorganic salts, separated from flammable liquids, organic acids, cyanides, and concentrated bases. Storage areas must be cool, dry, well-ventilated, and equipped with secondary containment berms to prevent environmental release in the event of liquid container failure.
Spill response, waste neutralization and environmental disposal
Managing accidental releases and routine waste streams containing copper sulfate is heavily governed by environmental protection statutes, including the US Clean Water Act (CWA), the Resource Conservation and Recovery Act (RCRA), and municipal publicly owned treatment works (POTW) pretreatment regulations. Because copper ions exert severe, irreversible toxicity on municipal biological wastewater treatment systems—specifically killing nitrifying bacteria responsible for sewage processing—direct sewer disposal is strictly prohibited in virtually all jurisdictions.
Solid Spill Protocol:
- Isolate and Protect: Restrict access to the spill zone. Ensure responders don full PPE, including chemical splash goggles, nitrile gloves, a lab coat, and a half-face respirator with P100 particulate filters if dust is present.
- Prevent Environmental Migration: Avoid dry sweeping or compressed air blowing, which aerosolizes fine cupric dust. If outdoors or near drains, immediately cover drainage channels and seal floor grates.
- Containment and Collection: Moisten the spilled powder lightly with water spray or damp inert absorbent pads to suppress dusting. Carefully sweep or shovel the solid into a dedicated, clean, labeled high-density polyethylene (HDPE) or poly-lined container. Seal the container tightly and label it as hazardous waste containing copper sulfate.
- Decontamination: Wipe down affected bench surfaces with damp disposable towels. Collect all cleaning towels as solid hazardous waste. Wash the area with a mild laboratory detergent, absorbing rinse waters with inert spill pillows.
Liquid Spill and Neutralization Chemistry:
When an aqueous copper sulfate solution spills, responders should contain the liquid with inert chemical absorbent booms (such as polypropylene, vermiculite, or diatomaceous earth). For small laboratory-scale waste streams, EHS departments often permit chemical precipitation prior to waste collection to concentrate the heavy metal sludge.
The standard neutralization and precipitation protocol involves slowly adding a dilute alkaline solution—such as 10% sodium carbonate (soda ash, Na2CO3) or agricultural lime (calcium hydroxide, Ca(OH)2)—to the acidic copper solution while monitoring pH. As the pH rises above 7.0, copper ions precipitate out of solution as basic copper carbonate (malachite-type precipitate, Cu2CO3(OH)2) or cupric hydroxide (Cu(OH)2):
2 CuSO4 (aq) + 2 Na2CO3 (aq) + H2O (l) → Cu2CO3(OH)2 (s) + 2 Na2SO4 (aq) + CO2 (g)
The mixture is allowed to settle for 24 hours until the supernatant liquid turns clear. The insoluble blue-green copper precipitate is collected via vacuum filtration using a Büchner funnel, transferred to a sealed hazardous waste container, and scheduled for licensed hazardous waste incineration or heavy-metal recovery. The clear aqueous filtrate must be verified to have copper concentrations below local POTW discharge limits (often strictly capped between 0.5 mg/L and 1.5 mg/L) before any drain disposal authorization is granted by the facility EHS officer.
For ongoing regulatory compliance and chemical hygiene planning, lab managers can cross-reference operational guidelines in our lab operations management hub to establish standardized chemical inventory controls and hazardous waste manifests across analytical facilities.
Frequently asked questions
Is copper sulfate classified as hazardous under GHS?
Yes, copper sulfate is officially classified as a hazardous chemical under GHS criteria across international jurisdictions. It carries the signal word Danger and is categorized for Acute Oral Toxicity (Category 4, H302: Harmful if swallowed), Serious Eye Damage (Category 1, H318: Causes serious eye damage), Skin Irritation (Category 2, H315: Causes skin irritation), and Aquatic Toxicity (Acute Category 1, H400 and Chronic Category 1, H410: Very toxic to aquatic life with long lasting effects).
What is the difference between anhydrous copper sulfate and copper sulfate pentahydrate on an SDS?
The two compounds differ in chemical formula, CAS registry number, molecular weight, and physical properties. Anhydrous copper sulfate (CuSO4, CAS 7758-98-7, MW 159.61 g/mol) is a hygroscopic, off-white to greenish-gray powder that dissolves exothermically in water. Copper sulfate pentahydrate (CuSO4 · 5H2O, CAS 7758-99-8, MW 249.68 g/mol) forms bright blue triclinic crystals containing approximately 36.1% water by weight. While both present identical cupric ion toxicities in solution, anhydrous powder presents unique thermal hazards upon rapid hydration.
Can copper sulfate solutions be poured down laboratory drains?
No, copper sulfate solutions must never be poured down sanitary or storm drains. Dissolved cupric ions are extremely toxic to aquatic ecosystems (Daphnia magna EC50 < 0.03 mg/L) and severely disrupt bacterial digestive processes at wastewater treatment facilities. All copper sulfate residues, rinse waters, and stock solutions must be collected in dedicated heavy-metal aqueous waste containers for hazardous waste processing.
What personal protective equipment is required when handling copper sulfate powder?
Mandatory PPE for handling copper sulfate includes indirect-vent chemical splash goggles meeting ANSI Z87.1 standards, chemical-resistant gloves (nitrile, neoprene, or PVC), a buttoned laboratory coat, long pants, and closed-toe impermeable footwear. If working outside a certified chemical fume hood where airborne dust concentrations approach or exceed 1 mg/m³, a NIOSH-approved respirator fitted with P100 particulate filters is required.
Why does copper sulfate pose a severe hazard to aquatic environments?
Cupric ions (Cu2+) act as potent non-specific enzyme inhibitors and cellular toxins in aquatic organisms. They bind to gill membranes in fish, impairing sodium transport and osmoregulation, and inhibit photosynthesis and enzymatic cell division in microalgae and aquatic plants. Because copper is an elemental transition metal, it does not degrade in the environment, persisting in aquatic sediments with severe chronic bioaccumulation risks.
What first aid measures should be taken if copper sulfate contacts the eyes?
Immediately flush the victim’s eyes with gently flowing potable water or isotonic saline at an emergency eyewash station for at least 15 to 20 minutes, holding the eyelids open and rolling the eyeball to ensure complete irrigation. Remove contact lenses if present and easy to do. Do not apply chemical neutralizers, ointments, or oils. Seek immediate emergency medical attention from an ophthalmologist or emergency physician, as delayed corneal ulceration and permanent vision loss can occur.
Sources
- National Library of Medicine (NLM) PubChem: Copper(II) Sulfate Pentahydrate Compound Summary (CID 24463, CAS 7758-99-8). https://pubchem.ncbi.nlm.nih.gov/compound/Copper_II_-sulfate-pentahydrate. Accessed 2026-11-15.
- National Library of Medicine (NLM) PubChem: Copper Sulfate Anhydrous Compound Summary (CID 24462, CAS 7758-98-7). https://pubchem.ncbi.nlm.nih.gov/compound/Copper-sulfate. Accessed 2026-11-15.
- ILO-WHO International Programme on Chemical Safety: International Chemical Safety Card (ICSC 1416) — Copper(II) Sulfate Pentahydrate. https://chemicalsafety.ilo.org/dyn/icsc/showcard.display?p_card_id=1416. Accessed 2026-11-15.
- New Jersey Department of Health: Right to Know Hazardous Substance Fact Sheet — Cupric Sulfate (Fact Sheet 0549). https://nj.gov/health/eoh/rtkweb/documents/fs/0549.pdf. Accessed 2026-11-15.
- European Chemicals Agency (ECHA): Substance Infocard & C&L Inventory — Copper Sulphate (EC 231-847-6, CAS 7758-98-7 / 7758-99-8). https://chem.echa.europa.eu/100.121.888. Accessed 2026-11-15.
- NOAA Office of Response and Restoration: CAMEO Chemicals Datasheet — Copper Sulfate, Pentahydrate (Record 20049). https://cameochemicals.noaa.gov/chemical/20049. Accessed 2026-11-15.
Data: Copper Sulfate Chemical Safety and Regulatory Exposure Limits
Comparative specifications, GHS hazard classifications, exposure thresholds, and aquatic toxicity endpoints for anhydrous and pentahydrate copper sulfate compiled from OSHA, NIOSH, ECHA, and manufacturer safety data sheets.
Period covered: 2024/2026. Coverage: United States and International.
| Parameter | Copper(II) Sulfate Pentahydrate | Copper(II) Sulfate Anhydrous | Regulatory or Standard Authority |
|---|---|---|---|
| CAS Registry Number | 7758-99-8 | 7758-98-7 | Chemical Abstracts Service / PubChem |
| Molecular Weight | 249.68 | 159.61 | IUPAC / PubChem Compounds CID 24463 and 24462 |
| Physical Form and Color | Bright blue crystalline solid | Off-white to greenish-gray powder | ILO-WHO ICSC 1416 / Fisher Scientific SDS |
| OSHA Permissible Exposure Limit (PEL) | 1 | 1 | OSHA 29 CFR 1910.1000 Table Z-1 (Dusts and mists, as Cu) |
| NIOSH Recommended Exposure Limit (REL) | 1 | 1 | NIOSH Pocket Guide to Chemical Hazards (10-hr TWA as Cu) |
| ACGIH Threshold Limit Value (TLV) | 1 | 1 | ACGIH (8-hr TWA, dusts and mists as Cu) |
| NIOSH IDLH Value | 100 | 100 | NIOSH Immediately Dangerous to Life or Health (as Cu) |
| Primary GHS Eye Hazard | Category 1: Causes serious eye damage (H318) | Category 2A / Category 1: Eye damage/irritation | ECHA Harmonised CLP / Regulation (EC) 1272/2008 |
| GHS Acute Oral Toxicity | Category 4: Harmful if swallowed (H302) | Category 4: Harmful if swallowed (H302) | ECHA Annex VI / UN GHS Classification |
| GHS Aquatic Toxicity | Category 1: Acute (H400) and Chronic (H410) | Category 1: Acute (H400) and Chronic (H410) | ECHA CLP Classification (M-factor = 10) |
| Oral LD50 (Rat) | 960 | 482 | NLM HSDB / ECHA Registered Substances Dossier |
| Daphnia magna 48-hr EC50 | 0.024 | 0.015 | EPA Pesticide Ecotoxicity Database / ECHA |
| Water Solubility (20 deg C) | 320 | 203 | ILO-WHO ICSC 1416 / PubChem |
| Recommended Protective Glove Material | Nitrile, Neoprene, or PVC | Nitrile, Neoprene, or PVC | NJ DOH Fact Sheet 0549 / Fisher Chemical SDS |
Sources
- PubChem Compound Summary: Copper(II) Sulfate Pentahydrate (accessed 2026-11-15)
- PubChem Compound Summary: Copper Sulfate Anhydrous (accessed 2026-11-15)
- ILO-WHO International Chemical Safety Card: Copper(II) Sulfate Pentahydrate (ICSC 1416) (accessed 2026-11-15)
- New Jersey Department of Health: Cupric Sulfate Hazardous Substance Fact Sheet (accessed 2026-11-15)
- European Chemicals Agency (ECHA): Substance Infocard & C&L Inventory — Copper Sulphate (EC 231-847-6) (accessed 2026-11-15)
- NOAA CAMEO Chemicals: Copper Sulfate, Pentahydrate (Record 20049) (accessed 2026-11-15)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.