The CUDIT-R (Cannabis Use Disorders Identification Test-Revised) is an 8-item self-report questionnaire that screens for problematic cannabis use over the past six months. Adamson and colleagues published it in 2010 as a shortened revision of the 10-item CUDIT, and the researchers reported 91% sensitivity and 90% specificity against a structured diagnostic interview in their derivation sample. Scores run from 0 to 32, and published materials attach different thresholds to them (8, 10, 12 and 13), so the threshold you report has to be named and justified in any study that uses it.
What the CUDIT-R measures in research
The CUDIT-R is a screening and outcome-monitoring instrument, not a diagnostic interview. Its authors describe it as well suited to screening for problematic cannabis use and as having potential as a brief routine outcome measure. In a research protocol it typically appears as one short module inside a larger survey or battery, where it supplies a continuous severity score or a dichotomous screen-positive flag for people who report recent cannabis use.
The instrument was derived from the original CUDIT, which had 10 items and attracted concern about the performance of individual items. The revision work used 144 patients in a clinical trial for concurrent depression and substance misuse. Each participant completed an expanded CUDIT (the original 10 items plus 11 candidate items) and was assessed for current cannabis use disorder with the Structured Clinical Interview for DSM (SCID). The final 8 items keep two items from each of four domains: consumption, cannabis problems (abuse), dependence and psychological features. The authors report that the shorter form has equivalent or superior psychometric properties to the original.
Two points matter for study design. First, the derivation sample was a clinical sample with comorbid depression and substance misuse, which is not the same population as regular recreational users in the community. Second, the reference standard in the derivation work was a clinical interview for cannabis use disorder, so the sensitivity and specificity figures describe agreement with that interview in that sample, not accuracy in every setting. The sections below show how much the figures move when the sample changes. If your design relies on a validated cut-off, read the survey research methods entry first for the wider context on instrument selection and administration mode.
Structure and scoring
Scoring rules below follow the Inquisit implementation manual published by Millisecond Software (library page for the CUDIT-R script, read 2026-11-14). The manual describes the measure as eight questions about cannabis use in the last six months, answered on a five-point frequency scale for most items.
- Screening question. The script opens with a yes/no question about whether the person has used cannabis in the last six months. In the raw data this item is coded 1 for yes and 0 for no. If the answer is no, the remaining questions are skipped.
- Frequency-type items. Questions 1 to 7 are coded 0 (never) to 4 (almost daily), as the manual’s data-file description gives it.
- Final item. Question 8 is coded 0, 2 or 4 rather than 0 to 4, according to the manual’s data-file description. Programme it with exactly those three codes, because treating it as a five-point item would inflate the total.
- No reverse scoring. The manual states that no items are reverse-scored.
- Total. The score (called
cuditRScorein the Inquisit summary file) is the sum of the scored items, with a possible range of 0 to 32.
Seven items scored 0 to 4 plus one item scored 0, 2 or 4 gives the 32-point maximum, which is a useful arithmetic check when you inspect your own scoring code. A participant who answers the screening question with no has no total in the usual sense, so decide in your analysis plan whether such participants are coded as 0, as missing, or analysed separately, and state the rule. The published materials do not make that choice for you.
The item wording itself is not reproduced here. Use the version supplied by the authors or by your survey platform, and cite Adamson et al. (2010) so that readers can trace the instrument.
Cutoffs and what validation studies report
Published materials do not agree on a single cut-off. The Inquisit manual’s scoring section treats a score of 8 or higher as hazardous cannabis use and a score of 12 or higher as possible cannabis use disorder that may need further assessment. A later psychometric paper (Bonn-Miller et al., 2016, Cannabis and Cannabinoid Research, PMC5531365, read 2026-11-14) evaluated a cut-off of 13, which its authors describe as derived from DSM-IV cannabis dependence, and then examined alternatives. The abstract of the 2010 paper reports sensitivity and specificity without naming a cut-off, so do not attribute a specific threshold to those two figures unless you have checked the full paper.
The 2016 study is the most useful for a researcher choosing a threshold, because it tested the full CUDIT-R in two community samples and used DSM-5 cannabis use disorder (two or more criteria) as the reference. One sample was 207 US medical cannabis dispensary clients (195 analysed) whose disorder status came from a self-report questionnaire derived from a structured clinical interview, using DSM-5 criteria without craving. The other was 369 Australian regular recreational users recruited for an online survey (366 analysed), assessed with modified AUDADIS-IV and CIDI items under the full DSM-5 criteria.
Cut-off 13
At 13, the full CUDIT-R was specific but missed many people who met the DSM-5 reference: sensitivity was 54.35% in the US sample and 60.84% in the Australian sample, with specificity of 97.09% and 89.50%. Cohen’s kappa was 0.53 and 0.52. For a screening tool, missing roughly four in ten reference-positive cases is a design consequence worth stating in a methods section. The Cohen’s kappa guide explains how to read those agreement values.
Lower cut-offs in community samples
The same paper reports that a lower threshold balanced sensitivity and specificity better: a cut-off of 10 in the US sample (sensitivity 80.43%, specificity 74.76%) and 9 in the Australian sample (sensitivity 80.72%, specificity 72.00%). The authors note that DSM-5 criteria are less stringent than the DSM-IV criteria behind the 13 threshold, and suggest that a cut of 10 may suit non-clinical samples. They also state that further validation is needed. The trade-off between the two error types is the standard receiver operating characteristic problem; see the ROC curve and AUC guide for how to choose and report a threshold from such a curve.
What this means for threshold choice
Three practical readings follow from the sources. The clinical-sample derivation and the community-sample re-evaluations are different evidence, so cite the one that matches your population. A threshold taken from a scoring worksheet (8 or 12) describes how a worksheet labels a score, which is different from a validated diagnostic accuracy figure. And when your analysis plan sets a threshold in advance, register it and report a sensitivity analysis at one neighbouring value, since the evidence above shows the figures are not stable across samples. The data table below compares the cut-offs, samples and accuracy figures side by side.
The three-item CUDIT-SF short form
Bonn-Miller and colleagues also derived a three-item short form, the CUDIT-SF, from the CUDIT-R using item response theory methods. It uses items 3, 5 and 6 of the CUDIT-R, and a score of 2 or higher is a positive screen. In the two samples it reached sensitivity of 78.26% and 78.31%, specificity of 76.70% and 78.00%, and area under the curve of 0.84 and 0.85. Its correlation with the full CUDIT-R was 0.84 in both samples, and its agreement with the full-form cut-off of 13 was 98% in the US sample and 93% in the Australian sample. Internal consistency (Cronbach’s alpha) was 0.66 in the US sample and 0.80 in the Australian sample.
The authors conclude that the CUDIT-SF may be useful in busy clinical settings for stepwise screening, and that larger and more varied samples are warranted. They also list limitations: craving was not assessed in the US sample, the two samples used different collection modes (paper and online), the design was cross-sectional, the observed disorder rates of about 46 to 47% were higher than in large epidemiological studies, and the samples did not come from primary care. The modest alpha in the US sample is a reminder to check reliability in your own data; the Cronbach’s alpha guide shows how.
Administering it as survey software (Inquisit)
Millisecond Software publishes a ready-made Inquisit script of the CUDIT-R. Its manual lists the script author as Katja Borchert, with the script created on 27 April 2018 and last modified on 24 May 2023, and states that the script is copyright Millisecond Software, LLC. That notice covers the software implementation. The manual page does not state a licence for the questionnaire itself, so take permission and citation terms for the instrument from the authors and the original journal, separately from the script terms.
The manual states the following about how the script behaves:
- It is a self-report measure of eight five-point questions about the last six months, with an estimated run time of 0.5 minutes.
- The page lists no configurable parameters. Instruction text sits in the script’s survey-page section, where captions under each survey page can be edited.
- Inquisit Lab writes one summary data file per participant,
cudit_r_summary.iqdat, and a raw data file,cudit_r.iqdat. - The page does not give installation or runtime steps, so follow the platform’s own documentation for installing Inquisit and running a script.
If you administer the measure on another platform, replicate the same logic: a gate on the yes/no question, 0 to 4 coding for the frequency items, the 0, 2, 4 coding for the final item, and no reversal. Report the platform and mode, because the two validation samples in the 2016 paper differed in mode (paper versus online) and the authors flag that difference.
Output and how to read it
The summary file contains participant, group and session identifiers, a completion flag (0 for not completed, 1 for completed), the elapsed time in milliseconds, the platform (Windows, Mac, iOS or Android), the yes/no response to the screening question, the item responses and cuditRScore. The raw file adds per-item response latencies in milliseconds, recorded for the last visit to each survey page.
Reading the output is a three-step habit. Filter on the completion flag first, so that partial records do not enter the total. Recompute the total from the item columns and confirm it equals the stored score and stays within 0 to 32. Then apply your pre-specified threshold and report it with its source, for example “a score of 8 or higher, as labelled in the Inquisit scoring documentation” or “a score of 13 or higher, as evaluated by Bonn-Miller et al. (2016)”. Treat the score as a screening result, never as a diagnosis of a person.
In a general sample many respondents can score at or near the minimum, so the distribution may bunch at the bottom of the range. The floor and ceiling effects guide covers how to detect and handle that in a total score, and the convergent and discriminant validity guide covers how to check that a short instrument behaves like related measures in your own data.
Troubleshooting scoring and reporting problems
- Totals above 32. The final item has only three codes (0, 2, 4). Coding it 0 to 4 or coding the yes/no screener into the sum pushes totals past the published range.
- Participants with no recent use. The skip rule means they never see the later items. Decide in advance how they enter the analysis and write the rule down.
- Threshold mismatch. Two papers can both say “CUDIT-R positive” and mean 8, 12 or 13. State the number and the evidence behind it.
- Diagnostic language. The instrument screens. Phrases like “participants with cannabis use disorder” overstate what a score of 12 or 13 shows; “screened positive” is accurate.
- Short form confusion. The CUDIT-SF uses a cut-off of 2 on three items. Do not apply the full-form cut-offs to it.
Alternatives to the CUDIT-R within the same family
The sources read for this page cover two relatives of the CUDIT-R. The comparison below uses only what those sources state.
| Instrument | Items | Relationship to the CUDIT-R | Source |
|---|---|---|---|
| CUDIT (original) | 10 | The predecessor, with concern about individual items; the CUDIT-R was built to replace it | Adamson et al., 2010 |
| CUDIT-R | 8 | Two items from each of four domains; scored 0 to 32 | Adamson et al., 2010; Millisecond manual |
| CUDIT-SF | 3 | Items 3, 5 and 6 of the CUDIT-R; positive screen at a score of 2 or higher | Bonn-Miller et al., 2016 |
The CUDIT-SF suits stepwise protocols in which a very short screen precedes the full CUDIT-R, which is the use its authors propose.
Sources
- Adamson SJ, Kay-Lambkin FJ, Baker AL, Lewin TJ, Thornton L, Kelly BJ, Sellman JD. An improved brief measure of cannabis misuse: the Cannabis Use Disorders Identification Test-Revised (CUDIT-R). Drug and Alcohol Dependence 2010;110(1-2):137-143. doi:10.1016/j.drugalcdep.2010.02.017 (PubMed 20347232, read 2026-11-14).
- Millisecond Software. CUDIT-R Inquisit script manual, https://www.millisecond.com/library/v7/cudit_r/cudit_r/cudit_r.manual (read 2026-11-14).
- Bonn-Miller MO and colleagues. Three-item CUDIT-SF derived from the CUDIT-R by item response theory. Cannabis and Cannabinoid Research 2016, https://pmc.ncbi.nlm.nih.gov/articles/PMC5531365 (read 2026-11-14).
Data: CUDIT-R and CUDIT-SF cut-offs, samples and published accuracy figures
Cut-off scores for the CUDIT-R and CUDIT-SF with the sample, reference standard and sensitivity and specificity reported in the 2016 Bonn-Miller et al. validation, compiled into one table from that paper and the Millisecond Inquisit scoring manual.
Period covered: 2016/2023.
| Instrument and cut-off | Sample or document | Reference or label | Sensitivity (%) | Specificity (%) |
|---|---|---|---|---|
| CUDIT-R, cut-off 8 | Millisecond Inquisit scoring manual | Labelled hazardous cannabis use (no accuracy figures given) | ||
| CUDIT-R, cut-off 12 | Millisecond Inquisit scoring manual | Labelled possible cannabis use disorder, further assessment (no accuracy figures given) | ||
| CUDIT-R, cut-off 13 | US medical cannabis dispensary clients, n=195 analysed | DSM-5 cannabis use disorder without craving, 2+ criteria | 54.35 | 97.09 |
| CUDIT-R, cut-off 13 | Australian regular users, n=366 analysed | DSM-5 cannabis use disorder, 2+ criteria | 60.84 | 89.5 |
| CUDIT-R, cut-off 10 | US medical cannabis dispensary clients, n=195 analysed | DSM-5 cannabis use disorder without craving, 2+ criteria | 80.43 | 74.76 |
| CUDIT-R, cut-off 9 | Australian regular users, n=366 analysed | DSM-5 cannabis use disorder, 2+ criteria | 80.72 | 72 |
| CUDIT-SF, cut-off 2 | US medical cannabis dispensary clients, n=195 analysed | DSM-5 cannabis use disorder without craving, 2+ criteria | 78.26 | 76.7 |
| CUDIT-SF, cut-off 2 | Australian regular users, n=366 analysed | DSM-5 cannabis use disorder, 2+ criteria | 78.31 | 78 |
Sources
- Bonn-Miller et al. 2016, CUDIT-SF from the CUDIT-R, Cannabis and Cannabinoid Research (PMC5531365) (accessed 2026-11-14)
- Millisecond Inquisit CUDIT-R script manual (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.