Written and maintained by CASRAI Editorial Board
Published
On this page
A cyclohexane safety data sheet (SDS) classifies the solvent as a highly flammable liquid (Flam. Liq. 2, H225) that is also an aspiration hazard (H304), a skin irritant (H315), a cause of drowsiness or dizziness (H336) and very toxic to aquatic life (H400, H410). The two supplier sheets compared here (Fisher Scientific EU, 2018, and Chevron Phillips Chemical, 2023) agree on that hazard set and on a flash point of about -18 °C; they differ in how they frame storage, incompatibilities and disposal.
This page reads the sheets side by side with the NIOSH Pocket Guide entry for cyclohexane (CAS 110-82-7), so a lab manager or EHS officer can see what is consistent across sources and what depends on the sheet’s jurisdiction and revision date. It summarises published safety information and does not replace the current SDS for the exact product on your bench.
Cyclohexane SDS at a glance
Cyclohexane (CAS 110-82-7) is a colourless, volatile hydrocarbon solvent. Every sheet read for this page lists the same six hazard statements and the signal word “Danger”. The practical consequences for a laboratory come mostly from the first one: the liquid ignites easily, its vapour can form explosive mixtures with air, and its flash point sits well below ordinary room temperature. The data table below the guide sets the three sources against each other attribute by attribute.
For the wider context of how sheets are structured and why older “MSDS” documents may still circulate, see SDS vs MSDS: what changed and whether legacy sheets are still valid.
GHS classification and H-statements on the cyclohexane SDS
The Fisher Scientific EU sheet (cat. 33117-2.5L, version 1.3, revised 05.11.2018) and the Chevron Phillips Chemical sheet (version 5.6, revised 2023-05-18) both carry the following classification.
- Flam. Liq. 2, H225: highly flammable liquid and vapour.
- Asp. Tox. 1, H304: may be fatal if swallowed and enters the airways.
- Skin Irrit. 2, H315: causes skin irritation.
- STOT SE 3, H336: may cause drowsiness or dizziness (the Fisher sheet names the central nervous system as the target).
- Aquatic Acute 1, H400 and Aquatic Chronic 1, H410: very toxic to aquatic life, with long-lasting effects. The Chevron Phillips sheet gives an acute M-factor of 1.
The Fisher sheet’s precautionary statements include P210 (keep away from heat and ignition sources), P284 (respiratory protection), P301+P330+P331 (if swallowed, rinse the mouth and do not induce vomiting), P302+P352 (skin contact), P304+P340 (inhalation) and P308+P313 (if exposed or concerned, seek medical advice). The statement attached to H304 is the one most often misread: the sheet says not to induce vomiting, because the aspiration hazard is the reason for the classification.
Cyclohexane flash point and flammability
What do the sources give for the flash point?
The Fisher sheet gives a closed-cup flash point of -18 °C and the Chevron Phillips sheet gives -18.3 °C (-0.9 °F), also closed cup. The NIOSH Pocket Guide lists 0 °F, which converts to about -17.8 °C. The three values are the same property reported to different precision, not a disagreement. A second figure matters for ignition control: both supplier sheets list an autoignition temperature of 260 °C (500 °F on the Chevron Phillips sheet).
What are the explosive limits?
NIOSH and the Chevron Phillips sheet give a lower explosive limit of 1.3 % by volume in air and an upper limit of 8 %. NIOSH also expresses its IDLH value of 1,300 ppm as 10 % of the lower explosive limit, which ties the health benchmark to the flammability benchmark. For the physical-property side of the compound (boiling point of 81 °C on the Fisher sheet), see the companion guide on the cyclohexane boiling point.
Because the flash point is far below room temperature, flammable vapour can be present in an ordinary lab without any heating. The Chevron Phillips sheet’s storage instruction of no smoking, with the container tightly closed, reflects this. Flammable-liquid categories and their thresholds are explained in the flammable liquid category guide.
Cyclohexane hazards beyond fire
Health hazards
The classification points to three health effects: aspiration into the lungs if swallowed (H304), skin irritation on contact (H315) and central nervous system effects from inhaled vapour (H336). Acute toxicity values on the sheets are comparatively high. The Fisher sheet lists an oral LD50 in rats above 5,000 mg/kg (OECD 401), and the Chevron Phillips sheet lists an inhalation LC50 in rats above 32,880 mg/m³ over four hours. Those figures explain why the sheets do not classify the substance for acute oral or inhalation toxicity, while the aspiration, skin and narcotic-effect classifications remain.
Environmental hazards
H400 and H410 put cyclohexane in the highest aquatic hazard category used on these sheets. In practice this is what turns a spill or a rinse down the drain from a housekeeping lapse into a reportable-waste question, which is why the disposal section below matters.
PPE and exposure limits
NIOSH and OSHA agree on the numerical limits: a time-weighted average of 300 ppm (1,050 mg/m³) for both the NIOSH recommended exposure limit and the OSHA permissible exposure limit, and an IDLH of 1,300 ppm. NIOSH advises preventing skin and eye contact, washing contaminated skin and removing wet clothing, noting that the clothing is flammable.
The Fisher EU sheet names protective equipment by European standard: respiratory protection to EN 136, 140 or 149 with an approved filter if vapour forms, safety glasses to EN 166, gloves to EN 374 and EN 511, and footwear to EN-ISO 20345. The Chevron Phillips sheet is less prescriptive on glove material. It tells the user to check permeability and breakthrough with the glove supplier and to discard gloves that show degradation, and it recommends an eye-wash bottle of pure water. Treat glove choice as a supplier-data question, and keep work in a ventilated enclosure such as a fume hood where the lab’s own risk assessment calls for it.
Storage and incompatibilities
All sources point the same way: keep cyclohexane in its original container, tightly closed, in a dry, cool, well-ventilated place, away from ignition sources. The Chevron Phillips sheet adds that opened containers should be resealed and kept upright, and gives a German storage class of flammable liquids. Storage details for solvents in laboratories are covered in the chemical storage cabinet guide.
Incompatibility wording differs by sheet. NIOSH lists oxidizers. Chevron Phillips names oxygen and strong oxidizing agents, with chlorates, nitrates and peroxides as examples. The Fisher EU sheet’s section 10.5 notes that plastic materials can be attacked and that explosive gas/air mixtures can form. A lab that stores cyclohexane with oxidizers because one sheet did not list them has read the sheet too narrowly; the union of the three entries is the safer reading.
Cyclohexane disposal
Disposal is where the two supplier sheets diverge most, because they apply different legal frameworks. The Fisher EU sheet directs disposal according to legal requirements and cites EC Directive 2006/12/EC, Directive 2008/98/EEC and Regulation 1013/2006; for transport it lists ADR UN 1145, class 3, packing group II. The Chevron Phillips sheet states that waste cyclohexane may meet the criteria of hazardous waste under the US Resource Conservation and Recovery Act (40 CFR 261), that it should go to a licensed hazardous-waste facility if so classified, and that recycling is preferred where possible.
Neither sheet gives a drain-disposal route, and the aquatic classification explains why. Contaminated lab waste programmes, container labelling and accumulation rules are set by the institution’s chemical hygiene plan and local rules; see the laboratory chemical hygiene plan entry for how those documents are organised.
What the comparison shows
Reading the three sources together gives four useful points that no single sheet states.
- The hazard classification is identical across the two supplier sheets, so a supplier change should not change the hazard communication label, though it should still be checked.
- Numeric properties (flash point, LEL/UEL, autoignition) agree within rounding, so differences between sheets come from wording and legal framing, not chemistry.
- Incompatibility and disposal text is where sheets differ, so these sections are the ones to compare when you hold sheets from more than one supplier.
- The revision date is part of the record: the Fisher EU sheet read here dates from 2018, the Chevron Phillips sheet from 2023. A laboratory file should hold the current sheet from the supplier of the product actually in use.
The same hazard-communication logic is applied to other solvents in the series; for a comparison point, see the toluene SDS guides on this site.
Where to get the cyclohexane SDS
The sheets used for this page are public: the Fisher Scientific EU SDS for cyclohexane, the Chevron Phillips Chemical cyclohexane SDS and the NIOSH Pocket Guide entry for cyclohexane. For a product in your inventory, the sheet that applies is the one issued by that product’s supplier for that product grade, in the language and jurisdiction of use.
Common misunderstandings
- “Same CAS number, same sheet.” Sheets for one CAS number differ in revision date, jurisdiction and section wording, as the table shows.
- “A flash point below zero only matters in winter.” The flash point is the temperature at which vapour can ignite; at -18 °C it is far below any lab temperature, so the liquid is ignitable at room temperature.
- “Low acute toxicity means low hazard.” The LD50 and LC50 values are high, but the classification rests on flammability, aspiration, skin and aquatic hazards.
- “Small volumes can go down the drain.” The H400/H410 classification and the disposal sections of both sheets point to hazardous-waste handling instead.
- “MSDS and SDS are interchangeable.” They are not; see the comparison page linked above.
Frequently asked questions
What does the cyclohexane SDS say about hazards?
It lists a highly flammable liquid (H225), aspiration toxicity (H304), skin irritation (H315), drowsiness or dizziness (H336) and very toxic effects to aquatic life (H400, H410), with the signal word “Danger”.
What is the flash point of cyclohexane?
The Fisher EU sheet gives -18 °C and the Chevron Phillips sheet -18.3 °C (closed cup); NIOSH lists 0 °F, about -17.8 °C.
How is cyclohexane disposed of?
The Chevron Phillips sheet says it may meet US hazardous-waste criteria (40 CFR 261) and should go to a licensed facility if classified; the Fisher EU sheet refers to EU waste legislation. Neither gives a drain route.
Is MSDS the same as SDS for cyclohexane?
The terms describe the older and current formats of the same document type; current sheets follow the GHS section structure used by the sources above.
Sources
- NIOSH Pocket Guide to Chemical Hazards, Cyclohexane: cdc.gov/niosh/npg/npgd0163.html (read 2026-11-14).
- Fisher Scientific EU, Safety Data Sheet, Cyclohexane, version 1.3, revised 05.11.2018: assets.fishersci.com (read 2026-11-14).
- Chevron Phillips Chemical, Safety Data Sheet, Cyclohexane, version 5.6, revised 2023-05-18: cpchem.com (read 2026-11-14).
Data: Cyclohexane safety attributes across NIOSH, Fisher EU and Chevron Phillips sources
Side-by-side comparison of cyclohexane (CAS 110-82-7) flash point, ignition data, exposure limits, classification, incompatibilities, storage and disposal framing as stated in the NIOSH Pocket Guide, a Fisher Scientific EU SDS (2018) and a Chevron Phillips Chemical SDS (2023).
Period covered: 2018/2023.
| Attribute | NIOSH Pocket Guide | Fisher Scientific EU SDS (rev. 2018) | Chevron Phillips SDS (rev. 2023) |
|---|---|---|---|
| Flash point | 0 °F | -18 °C closed cup | -18.3 °C (-0.9 °F) closed cup |
| Autoignition temperature | Not stated | 260 °C | 260 °C (500 °F) |
| Explosive limits (LEL / UEL, % by volume) | 1.3 / 8 | Not stated | 1.3 / 8 |
| Exposure limits | REL TWA 300 ppm; OSHA PEL TWA 300 ppm; IDLH 1300 ppm | Not stated | Not stated |
| GHS hazard statements | Not stated | H225, H304, H315, H336, H400, H410 | H225, H304, H315, H336, H400, H410 |
| Incompatibilities | Oxidizers | Plastic materials can be attacked; explosive gas/air mixtures | Oxygen and strong oxidizing agents (chlorates, nitrates, peroxides) |
| Storage wording | Not stated | Original container, tightly closed, dry, cool, well ventilated | Tightly closed, dry, well ventilated, no smoking; German storage class flammable liquids |
| Disposal framing | Not stated | Legal requirements (EC 2006/12/EC, 2008/98/EEC, Reg. 1013/2006); ADR UN 1145, class 3, PG II | May meet RCRA hazardous waste criteria (40 CFR 261); licensed facility; recycle if possible |
Sources
- NIOSH Pocket Guide to Chemical Hazards: Cyclohexane (accessed 2026-11-14)
- Fisher Scientific EU SDS Cyclohexane 33117-2.5L v1.3 (accessed 2026-11-14)
- Chevron Phillips Chemical SDS Cyclohexane v5.6 (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.