Cytology Slides: Types, Frosted Ends and Labeling

Cytology slide types, the frosted marking end, charged options and the labeling rules one cytopathology lab requires.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

Cytology slides are glass microscope slides used to hold a smear or a liquid-based preparation of cells for staining and examination. This guide is for clinic staff, laboratory buyers and students who need to tell the slide types apart and know what a cytology laboratory expects on the slide when it arrives.

What cytology slides are

A cytology slide is a microscope slide on which cells, rather than a tissue section, are spread or deposited. After staining (for example with the Papanicolaou stain) a cytologist examines the cells under the microscope. Who uses them: collection sites such as clinics that prepare conventional smears, and cytopathology laboratories that prepare and read slides.

How cytology slides are built

One manufacturer’s datasheet for liquid-based cytology slides (Typenex Medical, LBL-01362.1, checked 2026-11-01) describes hydrophilic surfaces, ground edges, 45-degree clipped corners and a white frosted coating on one end that serves as the marking area. Other makers’ slides differ, so the product’s own datasheet is the reference for any slide you actually buy.

Conventional smear vs liquid-based slides

The slide is handled differently in the two workflows. The rows below come from the UC Davis Health Cytopathology gynecologic submission instructions (checked 2026-11-01); they are one laboratory’s rules, and your own laboratory’s instructions take precedence.

Workflow What happens to the slide Key difference
Conventional smear The material is spread on the glass slide at the collection site, fixed there with an alcohol-based cytology fixative, and the slide travels in a cardboard or plastic slide container. The collection site handles the slide, so slide labeling and fixation happen there.
Liquid-based (ThinPrep) The sample goes into a vial instead of being spread on a slide at the collection site. The laboratory treats this as a separate vial workflow. A vial workflow separate from the slide-and-fixative workflow.

Frosted end, circles, brackets and charged slides

The frosted end is the writing area. The UC Davis instructions say that when slides are prepared at the collection site, the frosted end is labeled with two forms of patient identification in lead pencil. Specimens without two identifiers “will be considered unlabeled and may be rejected.” For general label guidance see microscope slide labels.

The Typenex datasheet lists liquid-based cytology slides in four marking configurations. Three are listed in both charged and non-charged versions; 2 brackets is listed as charged only:

Marking configuration Charged and non-charged options
1 circle Both listed
2 circles, stacked Both listed
2 circles, offset Both listed
2 brackets Charged only listed (LC0301)

The datasheet also gives a size of 25 x 75 mm and a thickness of 1 to 1.2 mm for these slides (one manufacturer’s values). Mailers and storage are listed as sold separately.

What to check when you select or receive slides

  • The slide has a frosted marking end, because the laboratory labels the frosted end in pencil.
  • The configuration (circle or bracket, charged or non-charged where both are listed) matches the preparation method the laboratory uses, as stated in its own instructions or the product datasheet.
  • Consumables are in date. The laboratory instruction states: “Do not use expired consumables.”
  • A slide container is on hand for transport; the laboratory names cardboard or plastic containers.

Where slides sit among regulated devices

From the openFDA device classification database on 2026-11-01: a cytology kit (product code OKY) is class 2 under 21 CFR 884.4530; automated cervical cytology slide processors (MKQ) and readers (MNM) are class 3; and a digital cervical cytology slide imaging system with an AI algorithm (QYV) is class 2 under 21 CFR 864.3900. Related pages: cytospin and coverslips.

Safe handling basics

Follow the receiving laboratory’s written instructions for fixation, containers and labeling, since acceptance criteria are set by that laboratory. Label with the identifiers it requires, in pencil on the frosted end.

Common mistakes

  • Labeling with only one identifier. The laboratory treats such specimens as unlabeled and may reject them.
  • Using expired consumables.

FAQ

What is the frosted end of a cytology slide for?

It is the marking area. One laboratory’s instructions require patient identification there, written in lead pencil, when the slide is prepared at the collection site.

Do conventional and liquid-based preparations use the same slide handling?

No. In the cited laboratory’s instructions a conventional smear is prepared on the slide at the collection site and fixed there, while a liquid-based sample goes into a vial.

What size is a liquid-based cytology slide?

One manufacturer lists 25 x 75 mm and 1 to 1.2 mm thick. Check the datasheet of the product you use.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Cytology Slides: Types, Frosted Ends and Labeling

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →